wellbots Evapolar Manuel utilisateur

Product Guide
Personal air cooler


Introduction
Congratulations! You bought Evapolar, your personal air cooler. To take full advantage
of the device please read the product guide before you start using it.
Intended use:
Evapolar is intended to cool and humidify the air creating a local microclimate in the area of 3-4 sq. m
(30-45 sq ft.). It also has a purication eect, ltering large dust particles from the air. The best eect
can be achieved indoors.
Safety regulations:
— The device will work correctly when placed on a smooth horizontal surface. Tilting it may cause a
water leak and damage the device.
— Do not carry the device when it is lled with water. Even after you empty the reservoir, some water
will still remain in the internal compartment. Please check the part of this manual about the device
transportation.
— For personal safety and proper functionality of the device use only clean, untainted tap water. If the
source of water is polluted and you are not sure about its safety, please use distilled water. It is rec-
ommended to perform the cleaning and technical maintenance of the device according to the “Device
maintenance” section of this product guide.
— The device is not intended for use in a highly polluted environment. Large dust particles, dirt, etc.,
can seriously aect the longevity of the device’s evaporative cartridge lifecycle.
— The device is not intended for use in a highly polluted environment. Large dust particles, dirt, etc.,
can seriously aect the longevity of the device’s evaporation cartridge lifecycle.
— Make sure water does not reach the external parts of the device. Do not use it near water, in a swim-
ming pool, in a bathroom, in a laundry room, outdoors when raining or at any other locations with high
humidity levels.
— In case of a leak or if water spills to the surface of the device, immediately disconnect the power cord
and let the device dry for at least 24 hours.
— Do not place the device under direct sunlight. 1.

— If you do not plan to use the device for a long time, empty the water reservoir and let the device work
at maximum power for at least 4 hours so that the cartridge can dry out.
— Only use the original power supply from the package.
— Do not touch the power supply or power cord with wet hands.
— Unplug the device in case of the following: cleaning, technical maintenance, removing/replacing
elements, moving the device.
— To maximize the eect the device should be placed on a higher surface, e.g. a table or a cupboard.
— Do not place the device next to a heater or in proximity of any electrical equipment.
— Do not place the device in passageways or any other location from where it can be accidentally
knocked over.
— Do not let any foreign objects inside the device.
— Do not place heavy items on top of the device.
— Do not block the front and back grills of the device.
— Do not turn the device upside down; it will disrupt its functionality.
— Do not submerge the device into water or other liquids, see cleaning guide below.
— Do not place open re sources (candles, etc.) on top of the device.
— People with limited physical, visual or mental abilities or lacking proper experience and/or knowledge
should never use the device without supervision of those responsible for their safety or those capable of
assistance in using the device.
— The device can be switched o completely only when disconnected from the power supply.
— The manufacturer does not bear any responsibility for any damage arising from failure to comply
with this product guide.
— A replaceable evaporative cartridge is designed specically for this product. If your cartridge has
been broken or damaged, you can purchase a replacement at Evapolar.com or with your local retailer.
2.

1. Slide the water reservoir up.
2. Open the lid to ll up the reservoir.
3. Place the reservoir on the base. Make sure it is installed properly.
4. Use the cable to connect the power supply to the device and the power source.
5. The device starts working.
The temperature of the outgoing air will start to decrease in a few minutes. You can vary airow level
using the rotation wheel on the upper part of the device.
Enjoy your personal microclimate!
Important: During the rst use there may appear some technical smell. This is normal
and It will vanish completely after several hours of work.
First start
90
1.
4.
5.
2.
3.
3.

Daily Use
We’ve made sure you won’t have to ne-tune your air cooler for too long. The device is ready to use
right after you unpack it. Afterwards, all you need to do is follow a few simple recommendations to
make your Evapolar experience as smooth as possible.
The air cooler creates a local comfort zone. To be in the center of that zone place the device within a
meter (3 ft.) away from you, with its front grill facing you. To keep the device out of your way, place it
slightly aside. This way you will always have room for a laptop or a book.
Placing the device
4.

Filling the reservoir
In order to work properly the device needs only water. You should remove the reservoir on the left side
of the device, ll it with water and then place it back. The water will start owing automatically.
Depending on the quality of the air in the room, the full reservoir should provide from 3 to 5 hours of
uninterrupted work. To extend this time you need to ll up the reservoir, place it on the device, wait until
the cartridge is full of water and then rell the reservoir. After this operation the running time will be
extended by 1 to 3 hours. For instance, this may be useful if you want the device to continue running
while you are asleep.
The transparent reservoir lets you assess the water level instantly. It is worth mentioning that the
evaporative cartridge will absorb up to 400 ml of water, which means that once the reservoir is empty,
the device will continue cooling for another few hours. The default mode will have the device notify you
when the water runs out. You can turn o the notications or change notication colors depending on
your liking.
When the water runs out completely, the device will continue working as a regular ventilator. You can
use the replaceable reservoir when the device is working, it will not aect its operation.
Transportation
Before any kind of transportation the device should be disconnected from the power source.
Besides the water in the transparent reservoir, the device stores some amount of water in the internal
tank so that the evaporative cartridge could absorb it. Before transportation, it is highly recommended
to empty the water out of the reservoir and let the device work on maximum fan speed for at least one
hour to dry the water out from the internal reservoir.
Transportation without drying the water out from the internal reservoir can only be done at your own risk.
Water leakage during the transportation is not covered by the warranty. In order to avoid leakage, the
device should be positioned horizontally and moved slowly.
5.

In order to remove the water instantly from the internal reservoir and prepare device for transportation,
please do the following:
1. Disconnect the device from a power source.
2. Remove the reservoir by sliding it up.
3. Use both hands to lift the upper part of the body. Push on both sides of its bottom part to release the
locks and then slide it upwards.
4. Tilt the device to the right while holding the cartridge and drain the water carefully.
5. Put the upper lid of the body back so that it ts the slots.
6. Put the reservoir back in place.
7. The device is ready for transportation.
Important: Even if there is no water in the internal reservoir, the evaporative cartridge could still be wet.
Do not transport the device with the wet cartridge for a long time. Please see section “Storage during
long periods of no usage” For short transportations make sure that the device with wet cartridge is not
isolated in a box or bag with no air ow.
1. 2. 3.
4. 5. 6. 7.
6.

Air parameters
Evapolar works using evaporative cooling so its power changes in various climate conditions.
The chart below shows cooling power approximates in various aerial conditions.
Usage modes
The device is created to be used at any location that meets humidity and temperature prerequisites from
the previous paragraph. Minimal power requirements allow the device to run even from a portable power
bank. Required electricity parameters: voltage 5V, current 2A and up.
Important: Since outside conditions can vary greatly, Evapolar is not responsible for the way the device
functions outdoors.
Tuning
You can alter the color and brightness level of the lighting, temperature measurement units and water
level indication. All of the above is done through the Menu, see paragraph on Control Panel and Menu.
Device Maintenance
Depending on how often you use the device, its internal camera needs cleaning, see paragraph on
Device Maintenance.
Temperature decrease chart
T ( C ) / rH (%)
30
40
50
60
70
25
9.6
8.1
6.6
5.3
4.1
30
11.0
9.1
7.5
5.9
4.5
35
12.4
10.2
8.3
6.5
5.0
40
13.7
11.2
9.1
7.1
5.4
7.

Important:
— Make sure that the air cooler is placed on a smooth horizontal surface to avoid leaks and spills.
— Do not use the device in the temperatures exceeding 60° C (140° F). Failing to do so can damage
both body and internal components of the device.
— Be careful using aromatic oils or incenses. The device evaporates water intensively so even a small
amount of odorous substances can oversaturate the air around you, which is potentially dangerous to
your health.
— To avoid spills do not move the device while it contains water. See paragraph on Transportation.
— Be careful when pouring water into the reservoir that is still attached to the device; do not spill water
on the body of the device.
Start screen
Control panel and menu
8.
Table des matières

















