Wellav CMP100 Manuel utilisateur

CMP100
Common Media Platform
User Guide
V1.2-W

CMP100 User Guide
i
Revision History
Date
Version
Description
Author
24/8/2017
1.0
First Version
ZM
06/06/2018
1.1
Add new modules, new features and adjust management page
ZM
15/11/2018
1.2
Modify the product picture
DA
This guide contains some symbols to call your attention.
DANGER
The DANGER symbol calls your attention to a situation that, if ignored, may cause
physical harm to the user.
CAUTION
The CAUTION symbol calls your attention to a situation that, if ignored, may cause
damage to Our product.
NOTE
The NOTE symbol calls your attention to important information.
TIP
The TIP symbol calls your attention to additional information that, if followed, can
make procedures more efficient.
Red Arrow
The Red Arrow symbols point to import details mention the context above or below
an image.
Blue Arrow
The Blue Arrow symbol indicates the motion path of an item in an operation step.
Thick Arrow
The thick Arrow symbol calls your attention to a serial of operation steps mentioned
in the context.
This guide also contains the following text conventions.
Bold Italic
The bold Italic text indicates a button to click, an item in the drop-down menu to
select, or a certain item in the UI.

CMP100 User Guide
ii
Safety Instructions
Read these instructions
Keep these instructions
Follow all instructions
Heed all warnings
Do not use this unit near water.
Only use a damp cloth to clean chassis
Do not install near any heat sources such as radiators, heat registers, stoves, or
other apparatus (including amplifiers) that produce heat
Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions
This unit is grounded through the power cord grounding conductor. To avoid
electrocution,do not remove the power cord before the outlet is switched off or unplugged. If
the plug does not fit into your outlet, consult an electrician for replacement of the outlet.
Route power cords and other cables so that they are not likely to be damaged.
Only use attachments/accessories specified by the manufacturer.
Do not wear hand jewelry or watch when troubleshooting high current circuits.
Do not work on the system during periods of lightning.
Refer all servicing to qualified service personnel. Servicing is required when this unit has
been damaged in any way.
Damage Requiring Service: Unplug this product from the wall outlet and refer
servicing to qualified service personnel under the following conditions:
When the power-supply cord or plug is damaged.
If liquid has been spilled, or objects have fallen into the product.
If the product has been exposed to rain or water.
If the product does not operate normally by following the operating
instructions. Adjust only those controls that are covered by the operating
instructions as an improper adjustment of the controls may result in
damage and will often require extensive work by a qualified technician to
restore the product to its normal operation.
If the product has been damaged in any way.
Replacement Parts: When replacement parts are required, be sure the service
technician uses replacement parts specified bythe manufacturer. Unauthorized part
substitutions made may result in fire, electric shock or other hazards.

CMP100 User Guide
iii
SAFETY PRECAUTIONS
There is always a danger present when using electronic equipment.
Unexpected high voltages can be present at unusual locations in defective equipment and
signal distribution systems. Become familiar with the equipment that you are working with
and observe the following safety precautions.
Every precaution has been taken in the design of the products to ensure that it is as safe as
possible. However, safe operation depends on you the operator.
Always be sure your equipment is in good working order. Ensure that all points of connection
are secure to the chassis and that protective covers are in place and secured.
Never work alone when working in hazardous conditions. Always have another person close
by in case of an accident.
Always refer to the manual for safe operation. If you have a question about the application or
operation contact the manufacturer for assistance.
Electrostatic Discharge (ESD) Caution:
Always wear an ESD-preventive wrist or ankle strap when handling electronic components.
Handle cards by the faceplates and edges only. Avoid touching the printed circuit board and
connector pins.
Avoid touching any electronic components while holding any module in hands.
Danger of explosion if battery is incorrectly replaced.

CMP100 User Guide
iv
Contents
PART 1 CHASSIS OVERVIEW...................................................................................................................................................1
1.1 PANEL............................................................................................................................................................................. 1
PART 2 INSTALLATION........................................................................................................................................................... 2
2.1 RACK INSTALLATION...........................................................................................................................................................2
2.2 AC POWER CONNECTION................................................................................................................................................... 2
PART3 WEBGUI...................................................................................................................................................................... 4
3.1 WEB GUI OVERVIEW........................................................................................................................................................ 4
3.1.1 Connecting to the Management Port··················································································································· 4
3.1.2 Logging into the Web GUI·····································································································································5
3.2 STATUS............................................................................................................................................................................5
3.3 SYSTEM SETTING...............................................................................................................................................................6
3.4 TSOIP INPUT....................................................................................................................................................................9
3.5 TSOIP OUTPUT...............................................................................................................................................................13
3.6 ADMIN..........................................................................................................................................................................16
PART 4 MODULE CONFIGURATION..................................................................................................................................... 17
4.1 RECEIVER DESCRAMBLING MODULES..................................................................................................................................17
4.1.1CR-DVBC/DTMB··················································································································································· 17
4.1.2 CR-DVBS2CI························································································································································· 20
4.1.3 CR-DVBS2FTA······················································································································································ 22
4.2 ENCODER MODULES........................................................................................................................................................22
4.2.1 CE-HDMI······························································································································································22
4.2.2 CE-CVBS·······························································································································································29
4.3 MODULATION OUTPUT MODULES......................................................................................................................................33
4.3.1 CM-QAM····························································································································································· 33
4.3.2 CM-DTMB····························································································································································35
4.3.3 CM-QAMA···························································································································································36
4.3.4 CM-OFDM··························································································································································· 36
PART 5 APPENDICES.............................................................................................................................................................37
APPENDIX A - ABBREVIATIONS................................................................................................................................................ 37
APPENDIX B- WARRANTY.......................................................................................................................................................39
APPENDIX C- AFTER-SALES SUPPORT....................................................................................................................................... 39

CMP100 User Guide
1
Part 1 Chassis Overview
1.1 Panel
CMP is a brand new Common Media Platform dedicated to commercial market, using the latest
commercial product design concept, with high density, high performance and high flexibility. By
carrying different types of function module, CMP100 can support almost any commercial application
with any combination of receiving, descrambling, encoding, multiplexing, and modulation in one
device.
1.Cooling Air Intake
2.4RU high density chassis
3.Remote network management
4.Dual power supply
5.16 hot-swappable modules

CMP100 User Guide
2
Part 2 Installation
2.1 Rack Installation
The CMP100 is designed to be mounted in a standard 19” rack. It takes 4RU of rack space. To install
it into a rack, please use the following steps:
1. Determine the desired position in the rack for the CMP100. Make sure that the air intake
on the top of the unit and the exhausts on the back of the unit will not be blocked.
2. Install the brackets at desired position if there’s no supporting plate in the rack.
3. Insert the rack mount clips into place over the mounting holes in the rack.
4. Slide the CMP100 into the position in the rack.
5. Secure the chassis to the rack by installing the four supplied screws through the front
mounting holes and tightening.
2.2 AC Power Connection
Please only use the supplied 3-prong power connector or one with equal specifications. NEVER
tamper with or remove the grounding pin. This could cause damage to CMP100, personnel, or
property. Make sure the power outlet is switched off before plug or unplug the power cable from the
panel of CMP100.
Dual Redundant Power Supply Specification:
AC INPUT 90~240VAC, 50/60Hz, 350W

CMP100 User Guide
3
When you take the equipment from a cold condition into a much warmer and humid condition,
the equipment should be acclimated to the warm and humidity condition for at least 30 minutes.
Powering up a non-acclimated unit may lead to shortcut or other damage to electronic components.
A professional UPS system is recommended for better performance of your content
distribution system.

CMP100 User Guide
4
Part3 Web GUI
3.1 Web GUI Overview
3.1.1 Connecting to the Management Port
Factory network settings of the Management Port:
IP address 192.168.1.10
Subnet Mask 255.255.255.0
Gateway 192.168.1.254
Use the following step to access the Web GUI in a browser.
Connect PC to CMP100 network port directly.
Connect other devices (IP signal Receiver or Sender) to CMP100 network port directly.
Set the IP address of the laptop/computer in the same network segment with the CMP100
Baseboard IP address. CMP100 will occupy up to 17 IP addresses. Please avoid setting IP
address of the connected PC or other devices same as the CMP100 occupied IP address
section.
Check the physical connection by ping command.
CMP100 possesses an embedded gigabit switch inside the chassis, you can use it as a switch
with other devices together. The four network ports are used for both managing and streaming at the

CMP100 User Guide
5
same time. A good method of checking multicast output is to check the output via VLC on your
control PC directly.
If you want to connect a switch between CMP100 and PC or other devices, this switch should
support IGMP V2 and IGMP snooping function. If the switch you used is not the correct configuration,
it could cause some network issue.
3.1.2 Logging into the Web GUI
Type the CMP100 Baseboard IP address into the URL field of any recommended browser (IE8 or
above, Firefox, and Google Chrome) to access the logon page. By default, the admin user account is
admin with password admin. Click Login or strike Enter on the keyboard to login to the GUI.
3.2 Status
Status>Device status
After a successful login, you will always enter the status overview page, where you can check the
device status of:
a) Module List: shows the module(s) inserted
b) Device and module status figure, fan running status and notes of ports, lights and buttons
c) Menu Bar and time display
Table des matières
Autres manuels Wellav Convertisseur de média

Wellav
Wellav NB100U Manuel utilisateur

Wellav
Wellav UMH-150 Manuel utilisateur

Wellav
Wellav NB100 Manuel utilisateur

Wellav
Wellav NB100U Manuel utilisateur

Wellav
Wellav SMP181-HLS Manuel utilisateur

Wellav
Wellav UMH160UIG Manuel utilisateur

Wellav
Wellav CMP201 Manuel utilisateur

Wellav
Wellav UMH252 Manuel utilisateur

Wellav
Wellav UMH160R Manuel utilisateur

Wellav
Wellav DMP900 Manuel utilisateur

















