W'eau WFI-005 Manuel utilisateur

Installation & Operation Manual
Swimming Pool Heat Pump
Model No.: WFI-005/007/010/013/017/021
ENGLISH/ DUTCH
Thank you very much for purchasing our product,please keep and read this manual carefully before
you install heat pump.


- 1 -
Fluorinated greenhouse gas – (R32)
The device contains the fluorinated greenhouse gas (R32) which is required for the device to work.
Industrial designation HFC-32
Common designation R32
Global warming potential (GWP) 675
Further information can be found on the device itself or the Specifications.
WARNING!
Risk of fire and explosion through leaking finned heat exchanger!
The refrigerant circuit of the finned heat exchanger contains highly pressurised, easily flammable,
odourless gas. Risk of fire and explosion in the event of uncontrolled gas leakage.
- Action of filling gas must be conducted by professional with R32 operating license.
- Keep the heat pump away from heat sources and naked flames.
- Do not drill into or scorch the heat pump.
- Do not use any objects apart from those permitted by the manufacturer to speed up the defrosting
process.
- Immediately shut off the heat pump if you suspect a gas leakage.
- The refrigerant is odourless. Always keep ignition sources away from the installation site of the heat
pump.
- Contact an authorized expert if you suspect a gas leakage.
WARNING!
Risk of electric shock!
A faulty electrical installation or a mains voltage that is too high can lead to electric shock.
- Have the installation, initial start-up and maintenance of the heat pump carried out by authorized
technician only.
- Please always cut the power supply if you want to open the cabinet to reach inside the heat pump
as there is high voltage electricity inside.
- Only start work on the heat pump after checking all safety regulations.
- Only connect the heat pump if the mains voltage from the power socket matches the voltage
indicated on the rating plate.
- Do not operate the heat pump if there is visible damage or the mains cable or the mains plug is
defective.
- Do not open the housing. Leave repairs to qualified specialists. Liability and warranty claims are

- 2 -
excluded in the event of repairs carried out on your own, improper operation.
- Ensure that children do not insert any objects into the fan blade and heat pump.
- Ensure that the electrical system to which the heat pump is connected has an earth conductor.
- If the unit would be installed where is vulnerable to lightning stroke, lightning protection
measurements must be carried out.
ATTENTION!
- The manufacturer declines any responsibility for the damage caused with the people,objects and of
the errors due to the installation that disobey the manual guideline. Any use that is without
conformity at the origin of its manufacturing will be regarded as dangerous.
- Please always keep the heat pump in the ventilation place and away from anything which could
cause fire.
- Don’t weld the pipe if there is refrigerant inside machine. Please keep the machine out of the
confined space when make gas filling by the authorized technician.
- Please always empty the water in heat pump during winter time or when the ambient temperature
drops below 0℃, or else the Titanium exchanger will be damaged because of being frozen, in such
case, it will be out of warranty for this machine.
* Content
1. Accessories description
2. Attention for safety
3. Installation of the unit
4. Specifications
5. Electrical Wiring
6. Instruction of operation
7. Adjusting and Initial operation
8. Operation and maintenance
9. Error codes & Solutions
10. WiFi-Function

- 3 -
1. Accessories description
Each unit produced by our factory is with the following accessories:
For function you need to purchase at least the following parts for each unit:
NOTE
The types and quantity of the water pipes, valves, filter equipment, sterilizing equipment which used for
the swimming pool heating/circulation pipe system, depend on the project design.
We suggest not to install auxiliary electric heaters in the system. If must install auxiliary electric heaters,
it should be operated by the specialized persons, and our company has no responsibility for all the
problem cause by the auxiliary electric heater.
Illustrations of machine
No.
Name
Qty.
Use
1
Instruction Manual
1 PC
Guide users to install the system
2
Drain-pipe
1 PC
Used for draining the condensate water
3
Drain-pipe connector
1 PC
Connect the drain pipe to the heat pump unit
4
Rubber shock absorber
4 PCS
Reduce vibration and reduce noise
5
Heat pump unit
1 SET
For heating water
6
Water connection
2 SET
Connect the piping system
No.
Name
Qty.
use
1
Water pump
1
Cycle the heated water
2
Filter system
1
Protect the heat pump from pool water
3
Water pipes system
1
Connect the equipment and make circulation

- 4 -
2. Attention for safety
Range of application:
1.Power supply: 220~240V/1N~50/60Hz.
2.Environment temperature: -15°C〜43°C
3.Water temperature range: 8°C~40°C in Heating function
8°C~28°C in Cooling function
●Confirm the ground connection, if the ground connection is not correctly done, it may cause
electric shock. And please cut off the power in the lightning storm weather.
●If install the heat pump in a small room, it must keep good ventilation.
●The main power switch should be out of the reach of Children.
●Don't put finger or stick into the air inlet or air outlet as the high-speed rotor may cause injury.
●When an exception happened (burning smell etc..), turn off the manual power switch immediately
and contact with after-sale service department.
●When the unit needs to be removed or re-installed or repaired, please entrust after-sale service
department and specialized personnel to do it. If the installation/ maintainence is not well done, it
may cause unit operation failure, electric shock, fire, hurt, leaking, etc.
●Must not be unauthorized reformed, otherwise it may cause electric shock or fire.
●Must not install the unit with combustible around.
●Confirm the installation base is strong enough to avoid falling of the heat pump.
●Confirm leakage protection switch is installed to avoid electric shock or other issues.
●When cleaning the unit, the operation should be stopped, and power switch should be turned off.

- 5 -
3. Installation of the unit
3.1 Installation Illustration
Above illustration is just for the reference, please take the advice of authorized installers.
3.2 Advised installation space
Keep the following indicated space for operation and maintenance when make the installation.

- 6 -
3.3 Additional By-pass kits
The additional By-pass kits is suggested to be put into the piping system to get the better adjustment
of water flow.
3.4 Heat pump unit size (mm)
A
B
C
D
E
F
G
H
I
J
WFI-005
463
764
736
510
348
324
180
98
25
30
WFI-007/010
591
864
836
640
379
355
290
107
30
15
WFI-013/017/021
641
924
896
640
390
376
340
107
26
11

- 7 -
3.5 Heat pump Exploded View
No.
Parts
No.
Parts
1
Fan protective gill
15
Water flow switch
2
Front panel
16
Titanium heat exchanger
3
Fan blade
17
Right structure
4
Fan motor
18
Manometer
5
Left panel
19
Right panel
6
Left structure
20
Control panel
7
Evaporator
21
Electrical terminal cover
8
Fan motor mount
22
Electrical terminal block
9
Upper structure
23
Electrical cable support
10
Electric box cover
24
Electronic expansion valve
11
Electrical box
25
Reactive resistance
12
Top cover
26
Bottom panel
13
Plastic net
27
Four-way valve
14
Middle panel
28
Compressor

- 8 -
3.6 Electrical connection
*Suggested power cable specification
Model
Power Cable Specification
WFI-005/007/010
3*1.5 mm²
WFI-013/017
3*2.5 mm²
WFI-021
3*4 mm²
Terminal
Terminal cable max. 4 mm²
*Electrical connection
Position L,N and is for the power connection of our heat pump.
Position P1 and P2 is for the Single phase water pump.
3.7 Condensation drainage
When machine running, there will be some condensation water on the base tray, which is the normal
situation. Please you can use the drainage jet and hose at the bottom of machine to drain the
condensation water. See below.
Ce manuel convient aux modèles suivants
5
Table des matières
Langues :
Manuels Pompe de piscine populaires d'autres marques

Resol
Resol DeltaSol B Pro Manuel utilisateur

Evolution Aqua
Evolution Aqua UniTech Perfect 5000 Manuel utilisateur

Outside Living Industries
Outside Living Industries Ubbink Heatermax Pool Guide de démarrage rapide

CPI
CPI Olympic 2P1815 Manuel utilisateur

Flotec
Flotec FP6121-01 Manuel utilisateur

Pentair
Pentair ONGA LEISURETIME LTP400 Manuel utilisateur