Vivid CAMERA LINK CLV-401 Manuel utilisateur

CLV-401 CAMERA LINKTM VIDEO SPLITTER
User’s Manual
Document # 200205, Rev 1.2, 6/12/2006
Vivid Engineering
418 Boston Turnpike #104 • Shrewsbury, MA 01545
Phone 508.842.0165 • Fax 508.842.8930
www.vividengineering.com • info@vividengineering.com

Table of Contents
1. Introduction 1
1.1. Overview 1
1.2. Features 2
1.3. Functional Description 3
1.4. Typical Applications 5
1.4.1. Standard Base Application 5
1.4.2. Medium Application 6
1.4.3. Cascaded Application 7
1.5. Specifications 8
2. Interface 9
2.1. Front Panel Connections 9
2.2. Rear Panel Connections 10
2.3. Video Connector Signals 10
2.4. Cable Shield Grounding 11
3. Mechanical 13
3.1. Dimensions 13
3.2. External Power Supply 14
4. Regulatory Compliance 15
4.1. FCC Compliance Statement 15
4.2. Canadian Compliance Statement 15
4.3. EU Notice (European Union) 15
5. Revision History 16

1
1. Introduction
1.1. Overview
The CLV-401 Camera LinkTM1Video Splitter interfaces one Camera LinkTM camera to
two frame grabbers using standard Camera LinkTM cables. This arrangement enables the
addition of a second frame grabber for functions such as camera setup, secondary/parallel
processing, and monitoring.
One frame grabber acts as master (i.e. primary) and provides control and communications
to the camera. The secondary (slave) frame grabber receives camera video data only. The
CLV-401 supports the Camera LinkTM “base” configuration. “Medium” configuration
applications are supported using two CLV-401s. Multiple CLV-401s may be cascaded to
support 4 or 8 frame grabbers.
The CLV-401 Camera Link TM Video Splitter is housed in a sturdy, compact aluminum
enclosure and is well suited for industrial environments.
V
ivid
E
ngineering
Camera Link Video
Splitter
CLV-401
CAMERA MASTER FRAME GRABBER
1The Camera LinkTM interface standard enables the interoperability of cameras and frame grabbers,
regardless of vendor. The Automated Imaging Association (AIA) sponsors the Camera LinkTM
program including the oversight Camera Link Committee, the self-certification program, and the
product registry. The Camera LinkTM specification may be downloaded from the AIA website,
found at www.machinevisiononline.org
Camera LinkTM is a trademark of the Automated Imaging Association

2
1.2. Features
•Interfaces one camera to two frame grabbers
•Second frame grabber can be used for camera setup, processing, monitoring, etc
•Uses standard Camera LinkTM cables (not included)
•Supports Camera LinkTM “base” configurations
•“Medium” configuration support using two CLV-401s
•Also acts as a repeater, doubling max distance between camera and frame grabber
•Sturdy, compact aluminum enclosure w/ mounting flange
•FCC, Canadian, and CE Regulatory Compliance
•3-year warrantee

3
1.3. Functional Description
A block diagram of the CLV-401 is provided in Figure 1-1. The CLV-401 interfaces one
camera to two frame grabbers. One frame grabber is the master (primary), and one frame
grabber is slave (secondary).
Channel
Link
Receiver
Channel
Link
Transmitter
LVDS
Receiver
LVDS
Transmitter
LVDS Rcvr
To Camera LinkTM Camera
Video
Data
Camera
Control
Serial
Comm
Link LVDS Xmtr
LVDS Xmtr
LVDS Rcvr
Video
Data
Camera
Control
Serial
Comm
Link
To Camera LinkTM
Frame Grabber (Master)
CLV-401 Camera LinkTM Video Splitter
Channel
Link
Transmitter
Video
Data
To Camera LinkTM
Frame Grabber (Slave)
Figure 1-1: CLV-401 Block Diagram
The interface between the camera and the master frame grabber contains the entire
Camera LinkTM signal set defined in the Camera Link Specification for “base”
configurations. This consists of video data, camera control, and serial communications.
The master frame grabber receives video data from the camera, and can also control and
communicate with the camera.
The interface between the camera and the slave frame grabber contains only the video data
signals. The slave frame grabber receives video data, but cannot control or communicate
with the camera.

4
Since the CLV-401 regenerates all signals, it also acts as a repeater and supports an
additional 10 meters of separation between camera and frame grabbers(s) using standard
Camera LinkTM cables.
The CLV-401 is also compatible with the second Camera LinkTM cable used in the
“medium” configuration, enabling a pair of CLV-401s to be used in parallel to support
medium configuration applications.
The CLV-401 is powered by an external wall plug-in power supply.

5
1.4. Typical Applications
1.4.1. Standard Base Application
A standard CLV-401 base application is shown in Figure 1-2. A Camera LinkTM base
configuration camera is connected to a single CLV-401 via a standard Camera LinkTM
cable. Two additional Camera LinkTM cables are then used to connect the CLV-401
to the master and slave Camera LinkTM frame grabbers.
The master frame grabber provides camera control and communications, and
performs the primary processing functions. The slave frame grabber cannot control or
communicate with the camera, but may be used for parallel processing, secondary
processing, camera setup, monitoring, etc.
V
ivid
E
ngineering
Camera Link Video
Splitter
CLV-401
CAMERA MASTER FRAME GRABBER
Camera Link
TM
Camera
Master
Camera Link
TM
Frame Grabber
CLV-401
Camera Link
TM
Video Splitter
Standard Camera Link
TM
Cables
Slave
Camera Link
TM
Frame Grabber
Figure 1-2: CLV-401 Standard Application (Base)

6
1.4.2. Medium Application
A CLV-401 medium application is shown in Figure 1-3. Medium configurations, in
which two cables connect the camera to the frame grabber, are supported using two
CLV-401s in parallel. A Camera LinkTM medium configuration camera is connected
to two CLV-401s via a pair of standard Camera LinkTM cables. Four additional
Camera LinkTM cables are then used to connect the CLV-401s to the master and slave
Camera LinkTM frame grabbers.
V
ivid
E
ngineering
Camera Link Vi deo
Splitter
CLV-401
CAMERA MASTER FRAME GRABBER
V
ivid
E
ngineering
Camera Link Vide o
Splitter
CLV-401
CAMERA MASTER FRAME GRABBER
Camera Link
TM
Camera
(Medium Config)
Master
Camera Link
TM
Frame Grabber
CLV-401 Camera Link
TM
Video Splitters (2)
Slave
Camera Link
TM
Frame Grabber
Figure 1-3: CLV-401 “Medium” Application

7
1.4.3. Cascaded Application
Multiple CLV-401s may be cascaded to support four or eight frame grabbers. An
application in which three CLV-401s are cascaded to interface four frame grabbers to
a Camera LinkTM base configuration camera is shown in Figure 1-4. Seven standard
Camera LinkTM cables are used to interconnect the equipment. Note that one frame
grabber is the master, and all remaining frame grabbers are slaves.
V
ivid
E
ngineering
Camera Link Video
Splitter
CLV-401
CAMERA MASTER FRAME GRAB BER
V
ivid
E
ngineering
Camera Link Video
Splitter
CLV-401
CAMERA MASTER FRAME GRABBER
V
ivid
E
ngineering
Camera L ink Vide o
Splitter
CLV-401
CAMERA MASTER FRAME GRABBER
Camera Link
TM
Camera
Master
Camera Link
TM
Frame Grabber
CLV-401 Camera Link
TM
Video Splitters (3)
Slave
Camera Link
TM
Frame Grabber
Slave
Camera Link
TM
Frame Grabber
Slave
Camera Link
TM
Frame Grabber
Figure 1-4: CLV-401 Cascaded Application

8
1.5. Specifications
Table 1-1: CLV-401 Specifications
Feature
Specification
Video Interfaces Camera Link Spec “base” configuration
Video Connectors 26-pin MDR type
Frequency Range 20 - 66 MHz
Chipset National Semi. DS90CR285 / DS90CR286A
Power Supply Optional US/Europe Transformer w/ Outlet Plug Set
Power Jack 2.1 x 5.5 mm, center-positive
Power Requirements 5-7 VDC, 350 mA (typical)
Cabinet Dimensions 5.28” (L) x 1.18” (H) 6.12” (D)
Weight 13 oz
Operating Temperature Range 0 to 50° C
Storage Temperature Range -25 to 75° C
Relative Humidity 0 to 90%, non-condensing