Vision techconnect control 3 Manuel utilisateur

1
TC2-CTL3_manual_en
TECHCONNECT CONTROL3
OWNERS MANUAL
www.visionaudiovisual.com/techconnect/tc2-ctl3

2
TC2-CTL3_manual_en
DECLARATION OF CONFORMITY
Where applicable Vision products are certified and comply with all known local regulations to a
‘CB Certification’ standard. Vision commits to ensure all products are fully compliant with all
applicable certification standards for sale in the EU and other participating countries.
The product described in this owner manual is in compliance with RoHS (EU directive
2002/95/EC), and WEEE (EU directive 2002/96/EC) standards. This product should be returned
to the place of purchase at the end of its useful life for recycling.
WARNINGS
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR
BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the
user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be
of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle, is intended to alert the user to the presence of
important operating and maintenance (servicing) instructions in the literature accompanying the
appliance.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.
All products are designed and imported into the EU by ‘Vision’ who is wholly owned by ‘Azlan
Logistics Ltd.’, Registered in England Nr. 04625566 at Lion House, 4 Pioneer Business Park,
Clifton Moor, York, YO30 4GH. WEEE Registration: GD0046SY
DECLARATION OF ORIGIN
All Vision products are made in the People’s Republic of China (PRC).

3
TC2-CTL3_manual_en
USE ONLY DOMESTIC AC OUTLETS
Connecting the unit to an outlet supplying a higher voltage may create a fire hazard.
HANDLE THE POWER CORD WITH CARE
Do not disconnect the plug from the AC outlet by pulling the cord; always pull the plug itself.
Pulling the cord may damage it. If you do not intend to use your unit for any considerable
length of time, unplug the unit. Do not place furniture or other heavy objects on the cord, and
try to avoid dropping heavy objects on it. Do not tie a knot in the power cord. Not only could
the cord be damaged, but a short circuit could also be caused with a consequent fire hazard.
PLACE OF INSTALLATION
Avoid installing this product under the following conditions:
• Moist or humid places
• Places exposed to direct sunlight or close to heating equipment
• Extremely cold locations
• Places subject to excessive vibration or dust
• Poorly ventilated places
Do not expose this product to dripping or splashing. DO NOT PLACE OBJECTS FILLED WITH
LIQUIDS ON OR NEAR THIS PRODUCT!
MOVING THE UNIT
Before moving the unit, be sure to pull out the power cord from the AC outlet and disconnect
the interconnection cords with other units.
WARNING SIGNS
If you detect an abnormal smell or smoke, turn this product off immediately and unplug the
power cord. Contact your reseller or Vision.
PACKAGING
Save all packing material. It is essential for shipping in the event the unit ever needs repair.
IF ORIGINAL PACKAGING IS NOT USED TO RETURN THE UNIT TO THE SERVICE CENTRE,
DAMAGE IN TRANSIT WILL NOT BE COVERED BY WARRANTY.

4
TC2-CTL3_manual_en
FRONT AND REAR PANELS
1. Learn Confirmation LED (green)
2. Learn Mode LED (red)
3. IR Receiver
4. Internal IR Blaster / Emitter
5. Function Buttons
6. RS-232
7. PWR in (12V 0.5A)
8. 12V Trigger out
9. RS-485
10. IR out
BUTTONS
1
2
5
3
4
6
7
8
9
10
1
2
3
4
5
6

5
TC2-CTL3_manual_en
CONTROL OPTIONS
IR
Techconnect Control learns and replicates codes sent from a device’s infrared remote control.
An IR emitter integrated into the front panel is adequate for small rooms.
For larger rooms three external wired IR emitters are included –one with a 10m cable, and two
without cables. Techconnect Minijack cables are suitable to extend these.
NOTE: There is no theoretical cable length limit on IR cables.
NOTE: Remote controls which come with projection screens are often RF –not IR. To control
these screens use the 12v trigger.
RS-232
Professional control format used to control a variety of devices including projectors. More
reliable than IR and uses two-way communication with the control device to confirm commands
has been received.
Requires 3-core cable.
NOTE: If using RS-232 the TC2-CTL3 needs to be mains-powered.
12v Trigger
Simple trigger voltage commonly used to activate projection screens. Requires 2-core
unshielded cable.
NOTE: If using 12v Trigger the TC2-CTL3 needs to be mains-powered.
RS-485
Using the same codes as RS-232, this protocol offers longer cable distances of around 100m,
and only requires 2-core cable. Few AV devices can decode RS-485.
If using an additional Control module to extend the keypad this terminal is used to connect the
slave module to the master.
NOTE: If using RS-485 the TC2-CTL3 needs to be mains-powered.

6
TC2-CTL3_manual_en
Note: Tx is normally wired to Rx. Extron requires you to wire Tx to Tx.

7
TC2-CTL3_manual_en
INSTALLATION
1. FIT LABELS Use flat-head screwdriver to unclip clear button covers, then apply labels as
shown:
2. SELECT POWER SOURCE The control module is set to be powered by mains power by
default. If you choose to power with 2 x AAA batteries (not included) move switch inside
the battery compartment to BATT.
NOTE 1: If powered by batteries buttons will only light when pressed.
NOTE 2: If powered by mains ensure batteries are not left in device.
3. CONNECT CABLES Connect appropriate cables and fit the module into the surround. In
very simple installations it may not be necessary to connect any cables.

8
TC2-CTL3_manual_en
SIMPLE MODE PROGRAMMING
Appropriate for controlling one IR device only, e.g. projector.
1. PUT DEVICE INTO LEARN MODE Press and hold buttons 3 and 4 (middle buttons). The
learn LED on the front panel will turn red and stay on.
2. PRESS BUTTON TO ASSIGN CODE TO Press function button on the front panel which the
incoming code will be assigned to. One code can be assigned to each button.
3. TEACH CODE Point remote control at the front panel of Control module. Press and hold the
button on the remote until the green confirmation LED flashes.
If red LED flashes it has failed to learn the code. Try again.
NOTE: Remote control should be 100mm from IR receiver and not held at an angle. Shield
from ambient light.
4. REPEAT The device will revert back to normal mode once it has learnt a code. Repeat steps
above to program other buttons.
BUTTON 2
Automatically sends code twice. Suitable for projector off. This can be disabled with the
computer software.
BUTTON 5/6
Sends codes repeatedly when held down. Suitable for volume control. This can be disabled
with the computer software.

9
TC2-CTL3_manual_en
ADVANCED MODE PROGRAMMING
NOTE: Device must use mains-power for these advanced functions.
Use when you need to
Program multiple codes to each button
Use RS-232 or 12v trigger
Add an extension keypad
Program scheduled actions
Duplicate to multiple devices
1. LOAD SOFTWARE ONTO PC Download from Vision’s website:
www.visionaudiovisual.com/techconnect/tc2-ctl3
2. CONNECT CONTROL MODULE VIA USB In the battery compartment there is a standard
USB-B mini connector. (USB cable not included)
The software can be used without a control module connected, but if learning IR codes you
will need to connect a control module.
3. LAUNCH SOFTWARE You can create a new program, edit program saved on PC, or edit
program saved on device.
If an extension keypad is used all code will be saved on
the master device. The slave device is connected to the
master via the RS485 terminal.
To find firmware version of your device click “Read CTL3
Time”

10
TC2-CTL3_manual_en
4. START BY ASSIGNING CODES click a button on the image. This window allows you to set
the codes for that button 1.
5. SELECT EXISTING CODES If codes are already in the library then select the device and
function in the drop-down menus. The code will appear.
NOTE: The software contains a pre-set library of RS-232 codes. When you add new codes
and sync and software, those new codes become available to all users when they sync
Repeat: when you hold the button down the codes are
repeatedly sent
Sequential: 1st press sends command 1, 2nd press sends
command 2, etc.
Simultaneous: All commands are send at the same time
Select
RS-232 / IR / 12V
Note: it is not possible to set
a delay for 12v triggers
Table des matières
Autres manuels Vision Télécommande
Manuels Télécommande populaires d'autres marques

Panasonic
Panasonic EUR7622KB0 Manuel utilisateur

Bang & Olufsen
Bang & Olufsen Beo4 Manuel utilisateur

Sunwave Tech.
Sunwave Tech. RemoteComm SRC-7000 Manuel utilisateur

Multiplex
Multiplex PROFI TX 9 Manuel utilisateur

One Remote
One Remote RMB4 Manuel utilisateur

FUTABA
FUTABA 9ZAP - PART2 Manuel utilisateur