Vision Tech Shop TPD Series Manuel utilisateur

TPD Series Interface Scale Operation Manual
CONTENTS
1. INTRODUCTION----------------------------------------------------------------------------- - 1 -
2. INSTALLATION------------------------------------------------------------------------------- - 1 -
2.1 Installation------------------------------------------------------------------------------ - 1 -
2.2 Leveling--------------------------------------------------------------------------------- - 1 -
2.3 Power Connection--------------------------------------------------------------------- 1 -
2.4 Rechargeable battery operation-------------------------------------------------- - 1 -
2.4.1 Charging the battery---------------------------------------------------------- 2 -
2.4.2 Battery maintenance-------------------------------------------------------- - 2 -
3. KEYS DESCRIPTION------------------------------------------------------------------------ 2 -
4. DISPLAY SYMBOLS------------------------------------------------------------------------ - 2 -
5. OPERATION------------------------------------------------------------------------------------ 3 -
5.1 Switching on/off----------------------------------------------------------------------- - 3 -
5.2 Zeroing---------------------------------------------------------------------------------- - 3 -
5.3 Using Tare------------------------------------------------------------------------------- 3 -
5.4 Select Weighing Units--------------------------------------------------------------- - 3 -
5.5 Back light Setting--------------------------------------------------------------------- - 4 -
5.6 Power auto off------------------------------------------------------------------------- - 4 -
5.7 Bluetooth Operation (Optional)--------------------------------------------------- - 5 -
5.7.1 Bluetooth Testing Tool Installation-------------------------------------- - 5 -
5.7.2 CON1 Communication Protocol Testing------------------------------- - 5 -
5.7.3 CON2 Communication Protocol Testing------------------------------- - 7 -
5.7.4 ASK Command Testing---------------------------------------------------- - 9 -
5.8 POS/ECR protocol selection----------------------------------------------------- - 11 -
6 PARAMETER SETTING-------------------------------------------------------------------- 12 -
6.1 MENU BLOCK----------------------------------------------------------------------- - 13 -
7. DIAGRAM: Serial interface---------------------------------------------------------------- 14 -
8. SPECIFICATION----------------------------------------------------------------------------- 15 -
9. DIMMENSIONS(inch/mm)----------------------------------------------------------------- 16 -
10.ERROR MESSAGE----------------------------------------------------------------------- - 17 -

TPD Series Interface Scale Operation Manual
- 1 -
1
2
3
1. INTRODUCTION
The TPD series interface scale that amplifies signals from a load cell, converts it to
digital data and displays it as a mass value
It is suitable for general weighing applications
15 mm LCD with white LED back light display
Standard RS232 port can be connected to computer, ECR or POS
Capacity 6 kg to 30 kg (12 lb to 60 lb)
2. INSTALLATION
2.1 Installation
Remove transport lock from bottom of the scale
base
Place the scale on a level surface
Install the stainless steel pan on top of the
plastic pan
Insert the pole (1) to pole bracket (3)
Fixing the pole(1) with screw (2)
2.2 Leveling
The scale is equipped with a level indicator located back side of device.
Use the adjustable leveling feet located on the bottom of the scale until the bubble
appears in the center of the indicator.
2.3 Power Connection
Connect the adaptor pin into the indicator adaptor jack.
Adaptor jack is locating below the left side of the scale.
Adaptor connects into your AC power socket. Plugable equipment must be installed
near an easily accessible socket outlet with a protective ground/ earth contact.
2.4 Rechargeable battery operation
Note: Please charge the battery before using the scale for the first time.
The symbol BATT on the weight display indicates that the battery is getting low.
it’s time to charge the battery with the AC power. If scale goes on being used without
proper charging, <BAT-LO> words will flicker on the display.
Approximately 1 hours of instrument usage are left; afterwards it will shut off
automatically.
Level bubble

TPD Series Interface Scale Operation Manual
- 2 -
Please use the supplied battery charger for charging the battery immediately,or scale
cannot be used.
2.4.1 Charging the battery
Before the first use, the battery should be charged by connecting it to the mains
power supply for at least 10 hours.
When the scale is plugged into the mains power the internal battery will be recharged.
Verify that the AC power socket outlet is properly protected.
Right side of the weight display there is an charging LED to indicate the status of
battery charging
Charge status of rechargeable battery is indicated by the LED display.
Red: Charging storage battery
Green: Rechargeable battery is completely charged
2.4.2 Battery maintenance
Do not use any other type of power adaptor than the one supplied with the scale.
Recharge battery should be charged in every three months when not in use.
If the scale is not used for an extended period of time,remove the battery from the
battery compartment to avoid leakage.
Store the battery in a sealed bag or box in a dry, temperate environment.
3. KEYS DESCRIPTION
4. DISPLAY SYMBOLS
CHARG
E
Charging indicator,indicates scale has been connected with power
STABLE
Stable indicator. Indicates the scale weight is stable.
NET
Net indicator. Indicates scale is displaying the net weight.
ZERO
Zero indicator.Indicates the scale is at zero.
kg
Indicates the unit of measure in use (kilogram).
lb
Indicates the unit of measure in use (pounds).
oz
Indicates the unit of measure in use (ounces).
Bluetooth indicator,Indicates the scale is in Bluetooth mode
BATT
Battery low indicator,Indicates the battery need to be charged
Keys
Description
1)On/Off key,Used to switch on/off the scale.
2)Zero key,Used to clear and zero the display.
3) Enter key, Used to confirm selection in parameters option.
4)Left arrow key. Used to shift the location and move the digit to the left.
1)Tare key,Used to perform a tare function, Subtracts weights.
2)Value increment key. Used to change the selected digit value.
3)Set up key,Used to enter setup menu setting.
4)To change the menu option in menu setting.
1)Units key,Used to change weighing units(kg/lb/oz).

TPD Series Interface Scale Operation Manual
- 3 -
5. OPERATION
5.1 Switching on/off
Switch on the scale by pressing key,Display will be show the scale version
and then come to normal weighing mode.
To switched off the scale, press key again.
5.2 Zeroing
Environmental conditions can lead to the balance exactly zero in spite of the platform not
taking any strain. However, you can set the display of your balance to zero any time by
pressing key and therefore ensure that the weighing starts at zero.
5.3 Using Tare
To enable Tare function, it’s required to enter parameters to select f4 tare >ON,
Before access to the parameter,it need to press the calibration switch that is locating
below the scale.
The weight of any container can be tared by pressing button so that with
subsequent weighing the net weight of the object being weighed is always displayed.
Taring a container
Load weight on the platform.
Press key. Zero is displayed, and tare is subtracted. The [] indicator above
Net indicator appears.
Remove weight on the platform. Tared weight is displayed. It can set only one tare
value. It will be shown with a minus value.
Clearing tare
To clear the tare value, remove the load from the platform
Press key. Zero is displayed, The [] indicator above Net indicator
disappears ,tare weight is cleared.
5.4 Select Weighing Units
By pressing key in turn in normal weighing mode,it can convert the weighing units
(kg/lb/oz),the relative symbol will turn on in the display.

TPD Series Interface Scale Operation Manual
- 4 -
5.5 Back light Setting
It allows choosing the back light operation.
1 Press key during that start up ,display will be show “F0 BL”
2 Press key to enter.
3 Press key to change the settings back light display mode
to Auto/Off/On.
4 Press key to confirm.
Display
Description
AUTO
Backlight will be turned on, when start to use or
when weight is not in zero.
oFf
Backlight function will be turned off
on
Backlight will be always turned on
Note:If battery is getting low, the backlight function will not available
5.6 Power auto off
1 Press key during that start up ,display will be show “F0 BL”.
2 Press key to select the menu until display show “F1 OFF”.
3 Press key to confirm.
4 Press key to select the options.
F1 OFF
off
To set auto off function turn off, for scale always on
3
Set to turn off 3 minutes later
10
Set to turn off 10 minutes later
30
Set to turn off 30 minutes later

TPD Series Interface Scale Operation Manual
- 5 -
5.7 Bluetooth Operation (Optional)
5.7.1 Bluetooth Testing Tool Installation
Note: The following steps used for testing communication (only BLE Utility available for
testing )
▪ Turn on the BLE Utility software in your phone, it can be download from
AppGallery
▪ Scale should be in the allowed limits of the distance to connect Bluetooth.
5.7.2 CON1 Communication Protocol Testing
1 Turn on the scale.
2 Press key during that start up ,display will be show “F0 BL”.
3 Press key until display show “F2 COM”.
4 Press key to confirm,display will be show “BT”
5 Press key to enter,display will be show “CON1”
6 Press key to confirm,display show “F2 COM”.
7 Press key to select “BACK” option.
8 Press key to confirm and back to normal weighing mode.
Testing steps in the mobile phone
1 Tab the connect button in your mobile phone to connect the Bluetooth module
2 Select the Unknown Service the last but one
3 Tab it and turn on the icon,Once set it successfully ,The [] indicator above[ ]
Bluetooth indicator in the scale appears.
4 Tab logs ,the weighing data will be show

TPD Series Interface Scale Operation Manual
- 6 -
①
②
③
④

TPD Series Interface Scale Operation Manual
- 7 -
5.7.3 CON2 Communication Protocol Testing
1 Turn on the scale.
2 Press key during that start up ,display will be show “F0 BL”
3 Press key until display show “F2 COM”
4 Press key to confirm,display will be show “BT”
5 Press key to enter,display will be show “CON1”
6 Press key to select “CON 2 ”
7 Press key to confirm,display show “STA ”
8 Press key to confirm
9 Press key to select “BACK” option
10 Press key to confirm and back to normal weighing mode.
Testing steps in the mobile phone
1 Tab the connect button in your phone to connect the Bluetooth module.
2 Select the Unknown Service the last but one .
3 Tab it and turn on the icon,Once set it successfully ,The [] indicator above[ ]
Bluetooth indicator in the scale appears .
4 Tab logs ,the weighing data will be show.

TPD Series Interface Scale Operation Manual
- 8 -
①
②
③
④
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels Vision Tech Shop Échelle

Vision Tech Shop
Vision Tech Shop TVC Series Manuel utilisateur

Vision Tech Shop
Vision Tech Shop TVD Series Manuel utilisateur

Vision Tech Shop
Vision Tech Shop TVD Series Manuel utilisateur

Vision Tech Shop
Vision Tech Shop DLP-300 Manuel

Vision Tech Shop
Vision Tech Shop VK-2D Manuel utilisateur

Vision Tech Shop
Vision Tech Shop VK-10S Manuel utilisateur

Vision Tech Shop
Vision Tech Shop DSW-100 Manuel utilisateur

Vision Tech Shop
Vision Tech Shop TVP Series Manuel utilisateur

Vision Tech Shop
Vision Tech Shop VK-4C Manuel utilisateur

Vision Tech Shop
Vision Tech Shop TVC Series Manuel utilisateur