VIP INTIPRDSG (GEN 3) Manuel utilisateur

Residential & Apartment
Intercom Systems
Installation Manual
Supports models from:
INT-Q1-22

VIP Vision Intercom Installation Manual - Version: INT-Q1-22
2
1. Pre-Installation
1.1 Please Read Before Installation 4
1.2 Device Models & General Use 5
2. Wiring & Connections
2.1 Connection Diagrams - Door Stations 7
2.2 Connection Diagrams - Indoor Monitors 11
2.3 Door Strike Wiring 12
2.4 Intercom Wiring 13
3. Intercom Setup
3.1 One Key Conguration 16
3.2 Manual Conguration of a Residential Intercom System 19
3.3 Manual Conguration of an Apartment Intercom System 26
3.4 Re-conguring an Existing Intercom for Use on the Network 32
4. Additional Conguration
4.1 Adding IP Cameras to an Indoor Monitor 33
4.2 Adding Your Door Station to a VIP Vision NVR 34
4.3 Issuing Cards (For Door Stations with a Built-In Card Reader) 35
4.4 Adding Entry Codes (For Door Stations with a Built-In Keypad) 36
4.5 Setting Time & Date 37
4.6 Changing Door Station Video & Audio Settings 37
4.7 Door Station Latch Timing 38
4.8 Adjusting Monitor Audio Settings 38
4.9 Changing the IP Address of a Windows Computer 39
4.10 Finding Available IP Addresses 41
4.11 Using Cong Tool to Find & Initialise Devices on a Windows Computer 42
4.12 Initialising Devices With Cong Tool 42
4.13 Modify Device IP Addresses with VDP Cong Tool 43
Table of Contents

3
Visit help.c5k.info for more information and support
Table of Contents
5. Mobile App
5.1 Remote Access for Residential Systems 44
5.2 Push Notications 45
5.3 Apartment Intercom Remote Access 45
6. Using the Intercom System
6.1 Making and Answering Calls 46
6.2 Taking Videos / Snapshots from the Indoor Monitor 46
6.3 Viewing Your Videos/Snapshots from the Indoor Monitor 46
6.4 Calling Between Indoor Monitors 47
6.5 Create Favourites 47
7. Troubleshooting
Factory Reset Intercom Devices 48

VIP Vision Intercom Installation Manual - Version: INT-Q1-22
4
1. Pre-Installation
Thank you for purchasing this Intercom System. This install guide
covers basic setup, installation and use of your intercom system.
For detailed technical support and software downloads, visit our
Help Centre at: help.c5k.info
help.c5k.info
• Settings password is user congured upon initial setup, it can be
entered after holding the Settings button for 6 seconds.
• Door Station’s default IP address is 192.168.1.108
• The Door Station’s username is “admin” and the password is
user congured upon initial setup. Please note that only the Door
Station has a web interface - the Indoor Monitor does not.
• If this is your rst time purchasing a VIP Residential IP Intercom,
we recommend setting it up on the bench before installation, to familiarize yourself with the
product. Upon installation, we recommend bringing a laptop to site to make any settings
changes that may be required. An understanding of basic computer networking is required.
• The IP intercom requires a CAT5e/CAT6 cable to be run between the Indoor Monitor and
Door Station. The cable must be terminated to TIA-568A or TIA568B standards. If you wish to
connect to the system remotely, your Indoor Monitor and Door Station must be connected to
your modem or network switch (sold separately) via a CAT5e/CAT6 cable.
• Power must be provided to each Door Station and Indoor Monitor - this can be done via Power
other Ethernet with a PoE switch, or via a separate DC power supply. Alternatively, 2-Wire
cabling can be used (available on select models only).
IMPORTANT:
• Door Stations are designed to mounted in a sheltered location, not exposed directly to weather.
• When installing the Door Station, apply outdoor silicone sealant between the Door Station and
the wall, and seal the hole that has been created for the cable to prevent water ingress. If using
a mounting box, ensure the box is also sealed, and the included waterproof rubber seals are
used when installing the screws.
1.1 Please Read Before Installation

5
Visit help.c5k.info for more information and support
Single Call-button IP Door Stations
Image
Model INTIPRDSG (GEN 3) INTIPRDSG-P INTIPRDSJ INTIPRDSD
Features 2-Wire & IP
12V Out for Relay/INTIPDM
IP Only
12V Out for Relay/INTIPDM
IP Only
Card Reader
IP Only
Card Reader
Keypad for Unlock
12V Out for Relay/INTIPDM
Max Additional
Door Station 20 20 20 20
Max Monitors 10 10 10 10
Power DC 48V
1A, POE
DC 12V-24V
1A, POE
DC 12V
1A, POE
DC 12V
1A, POE
Remote Access Yes Ye s Yes Ye s
Multiple Call-button & Apartment IP Door Stations
Image
Model INTIPDDS2 INTIPDDS4 INTIPADSD
Features
IP Only
2 Call-buttons
Card Reader
IP Only
4 Call-buttons
Card Reader
IP Only
Card Reader
Keypad for Calling/Unlock
12V Out for Relay/INTIPDM
Max Additional
Door Station 20 20 10
Max Monitors 10 10 200
Power DC 12V 1A, POE DC 12V 1A, POE DC 12V 2A, POE
Remote Access Yes (One QR code per Main Monitor) Yes (One QR code per Main Monitor) N/A
1.2 Device Models & General Use

VIP Vision Intercom Installation Manual - Version: INT-Q1-22
6
1.2 Device Models & General Use
Indoor Monitors & Accessories
Image
Model INTIPMONGW
INTIPMONGB INTIPMONGBL INTIPMONDWH2
INTIPMONDBH2 INTIPMON INTIPDM
Features 7’’ IP Monitors 10’’ IP Monitors 7’’ IP Handset Monitors 7” IP Monitor Door Expansion Module
Power 12VDC / PoE 12VDC / PoE 12VDC / PoE 12VDC / POE (Requires
INTIPMONPOE) 12VDC
GEN.3 2-Wire
INTIPRDSG(GEN.3) INTIPMON2W2 INTIPPOE2W2
2-Wire & IP
12V Out for Relay/INTIPDM 7” 2-Wire Monitor 2-Wire Network
Controller
Power via INTIPPOE2W Power via INTIPPOE2W 48VDC

7
Visit help.c5k.info for more information and support
2.1 Connection Diagrams - Door Stations
2. Wiring & Connections
2.1.1 INTIPRDSG, INTIPRDSG-P & INTIPRDSG (GEN.3) - G Series Residential Door Station
INTIPRDSG(GEN.3)INTIPRDSG-P
Name Description
Ethernet Port Power over Ethernet & network connectivity
Reset Button Reset conguration back to factory default settings
Tamper Switch The Door Station will generate an alarm sound if it is being removed from the wall
8-Pin
Connector
EOC1 (GND) (INTIPRDSG Only) 12V DC negative input/2-Wire connection port
2-wire-(GND) (INTIPRDSG GEN.3 Only) 48V DC negative input/2-Wire connection port
GND (INTIPRDSG-P Only) 24V DC negative input
EOC1 (+12) (INTIPRDSG Only) 12V DC positive input/2-Wire connection port)
2-wire-(48V) (INTIPRDSG GEN.3 Only) 48V DC positive input/2-Wire connection port
+24V (INTIPRDSG-P Only) 24V DC positive input
ALARM_COM Alarm common comtact
ALARM_NO Alarm normally open contact
RS485A For use with the INTIPDM
RS485B For use with the INTIPDM
12V_OUT 12V DC positive output, 100ma max current. For use with the INTIPDM
GND Ground connection for 12V_OUT
6-Pin
Connector
DOOR_NO Door relay normally open contact
DOOR_COM Door relay common contact
DOOR_NC Door relay normaly closed contact
GND Ground connection for DOOR_FB or DOOR_BUTTON
DOOR_FB Door latch feedback input, for use with monitored door latch
DOOR_BUTTON Exit button dry contact input, triggers door relay when shorted to GND

VIP Vision Intercom Installation Manual - Version: INT-Q1-22
8
2.1 Connection Diagrams - Door Stations (cont.)
2.1.2 INTIPDDS2 & INTIPDDS4 - Residential Door Stations
Name Description
Ethernet Port Power over Ethernet & network connectivity
12-Pin
Connector
12V 12V DC positive input
GND 12V DC negative input / Ground connection for FEEDBACK or Unlock
NO Door relay normally open contact
COM Door relay common contact
NC Door relay normally closed contact
FEEDBACK Door latch feedback input, for use with monitored door latch
UNLOCK Exit button dry contact input, triggers door relay when shorted to GND
RS485A For use with the INTIPDM
RS485B For use with the INTIPDM
ALM_IN Alarm input contact
ALM_NO Alarm normally open contact
ALM_COM Alarm common contact

9
Visit help.c5k.info for more information and support
2.1 Connection Diagrams - Door Stations (cont.)
2.1.3 INTIPRDSJ - J Series Residential Door Station
Name Description
Ethernet Port Power over Ethernet & network connectivity
Reset Button Reset conguration back to factory default settings
Tamper Switch The Door Station will generate an alarm sound if it is being removed from the wall
12-Pin
Connector
12V 12V DC positive input
GND 12V DC negative input
NO Door relay normally open contact
COM Door relay common contact
NC Door relay normally closed contact
FEEDBACK Door latch feedback input, for use with monitored door latch
UNLOCK Exit button dry contact input, triggers door relay when shorted to GND
GND Ground connection for FEEDBACK or UNLOCK
RS485A For use with the INTIPDM
RS485B For use with the INTIPDM
N/A Not used

VIP Vision Intercom Installation Manual - Version: INT-Q1-22
10
Name Description
Ethernet Port Power over Ethernet & network connectivity
Reset Button Reset conguration back to factory default settings
Tamper Switch The Door Station will generate an alarm sound if it is being removed from the wall
12-Pin
Connector
DC_IN 12V DC positive input
GND 12V DC negative input
ALM_OUT_NO Alarm output normally open contact
ALM_OUT_COM Alarm output common contact
GND Ground contact to be used with ALM_IN
ALM_IN Alarm input contact
NO Door relay normally open contact
COM Door relay common contact
NC Door relay normally closed contact
GND Ground connection for SR or PUSH
PUSH Exit button dry contact input, triggers door relay when shorted to GND
SR Door latch feedback input, for use with monitored door latch
8-Pin
Connector
12V_OUT 12V DC positive output, 100ma max current (for use with the INTIPDM)
GND Weigand card reader ground connection
WG_D1 Weigand card reader D1 connection
WG_D0 Weigand card reader D0 connection
WG_LED Weigand card reader LED connection
GND Ground connection for 12V_OUT
RS485B For use with the INTIPDM
RS485A For use with the INTIPDM
2.1 Connection Diagrams - Door Stations (cont.)
2.1.4 INTIPADSD - Apartment Series Door Station
Ce manuel convient aux modèles suivants
9
Table des matières
Autres manuels VIP Système d'interphone


















