LED Status Description
PWR OFF Mains power supply not present
ON Mains power supply present
MRX 1 blink Saving a new remote control
2 blinks Saving a remote control already in memory
3 blinks Deleting a remote control
4 blinks Radio memory full
5 blinks Attempt to store a remote control with a dierent code from the one used to set the receiver
10 blinks Complete deletion of the radio memory
51 OFF Step-by-step input (term. 51) not engaged
ON Step-by-step input (term. 51) engaged
52 OFF Pedestrian input (term. 52) not engaged
ON Pedestrian input (term. 52) engaged
61 OFF Stop contact (term. 61) open (engaged)
ON Stop contact (term. 61) closed (not engaged)
62 OFF Photocell engaged when closing (term. 62 open)
ON
Photocell not engaged when closing (term. 62 closed)
63 OFF Photocell or safety edge engaged (term. 63 open)
ON Photocell or safety edge not engaged (term. 63 closed)
SW1 OFF Limit switch 1 (corresponding to the right limit switch bracket marked DX) not used
ON Limit switch 1 engaged
SW2 OFF Limit switch 2 (corresponding to the left limit switch bracket marked SX) not used
ON Limit switch 2 engaged
10 Remote control programming
Note: Remote control programming can only be done with the automatic gate system stationary
Step-by-step programming
No. Pressing push button Signal
MRX LED Description
1MRX O Press and hold down the MRX push button for no more than 7 s
2MRX + remote control - With the MRX push button still pressed, press the button of the remote control to be saved
3- 1 blink Button of the saved remote control (new remote control)
2 blinks Button of the saved remote control (remote control already in memory)
Programming the pedestrian
No. Pressing push button Signal
MRX LED Description
1MRX + PRG O Press and hold down the MRX and PRG push buttons for no more than 7 s
2MRX + PRG + remote control -With the MRX and PRG push buttons still pressed, press the button of the remote control to be
saved
3- 1 blink Button of the saved remote control (new remote control)
2 blinks Button of the saved remote control (remote control already in memory)
Deleting a remote control
No. Pressing push button Signal
MRX LED Description
1MRX On steady Press and hold down the MRX push button for at least 7 s until the MRX LED comes on steady
2MRX + remote control - With the MRX push button still pressed, press the button of the remote control to be deleted
3- 3 blinks Deletion successful
Complete deletion of the receiver
No. Pressing push button Signal
MRX LED Description
1MRX Flashing light Press and hold down the MRX push button for at least 14 s until the MRX LED starts ashing
2- 10 blinks Complete deletion of the receiver
Note:
After deleting all the remote controls, the rst saved remote control congures the control panel to accept only remote controls with a rolling