Victron energy SmartSolar Control display Manuel utilisateur

SmartSolar Control display
manual
Rev 00 02/2021
ENGLISH

Table of Contents
1. Introduction ........................................................................................................................... 1
2. Installation ............................................................................................................................. 2
3. Operation .............................................................................................................................. 3
3.1. Status menu .................................................................................................................. 3
3.2. History menu ................................................................................................................. 5
3.3. Setup menu .................................................................................................................. 7
4. Troubleshooting and Support ................................................................................................... 12
4.1. The display does not power up .......................................................................................... 12
4.2. The display segments are faint or missing ............................................................................. 12
4.3. Display keeps scrolling through different menu items ................................................................. 12
4.4. Settings locked ............................................................................................................ 12
5. Warranty ............................................................................................................................. 13
6. Specifications ....................................................................................................................... 14
SmartSolar Control display manual

1. Introduction
The SmartSolar Control display is a dedicated display for the following MPPT solar charger ranges:
• SmartSolar MPPT 150/45 up to 250/100
• SmartSolar MPPT 150/70 up to 250/100 VE.Can
• BlueSolar MPPT 150/70 up to 250/100 VE.Can
These solar chargers can also be recognised by a small plastic cover on the front face with the text "display option".
Example of a solar charger without display and with display
The display plugs directly into the front face of the solar charger. It can act as both a permanent or a temporary display. Simply
remove the plastic cover that protects the display terminal on the front of the controller and then plug in the display.
The display can be used to monitor the solar charger and to view both live and historic data. The display can also be used to
configure solar charger settings.
Examples of live and historic monitoring:
• PV power, yield, voltage and current.
• Battery voltage, current and charge stage.
• Load output state and current (only available if the solar charger is equipped with a load output).
• 30-day historical values.
• Cumulative historic values over the live of the solar charger.
SmartSolar Control display manual
Page 1 Introduction

2. Installation
The display connects to the display terminal on the front of the solar charger. The display terminal is located behind the plastic
cover with the text: "display option".
To install the SmartSolar Control display do the following:
1. Remove the two screws of the plastic cover. Keep the screws, they are needed again when securing the display.
2. Remove the plastic cover. The display terminal is now exposed.
3. Remove the two plastic plugs on either side of the display plug.
4. Remove the paper backing of the double sided tape on the back of the display.
5. Insert the display into the plug and make sure it has been inserted all the way in.
6. Screw the display down by using the two screws that were used for the plastic cover.
How and where to connect the SmartSolar Control display
If the display is used as a temporary display, it is not necessary to use the tape and to screw down the display
into the solar charger.
The display is hot-swappable, this means that the display can be plugged in or removed while the solar
charger is operating.
SmartSolar Control display manual
Page 2 Installation

3. Operation
The LCD screen displays the following information:
• A number reading.
• The unit of the reading: V, A, W, kWh, h or °C/°F.
• The type of reading: battery, PV or temperature.
• State: charge and charge stage indication.
• Connection indicator and warning indicator.
Full LCD readout
The digits used to represent letters and numbers
The buttons on the front of the display are used to navigate through the solar charger readings and are used when making solar
controller and display settings.They have the following functions:
Button Action
Cancel
or
Back
Select
or
Conform
Go to next or previous item
or
Increase or decrease value
3.1. Status menu
This menu shows the live solar charger readings. The SmartSolar Control display always starts up in this menu.
SmartSolar Control display manual
Page 3 Operation

Press the - and + button to cycle through all menu items.
Press the - button to see the live data of the solar charger. Each time the - button is pressed, the next parameter will be displayed.
If the + and - button is pressed at the same time for 4 seconds, the auto scroll mode will be activated. The display will
continuously cycle through each menu item every 5 seconds. To stop the auto scroll mode, briefly press the "-" or the "+" button.
These menu items will be displayed in order of appearance as indicated in below table:
LCD display Menu item Description and notes
Battery voltage and
charge current when
no PV is present
Battery voltage and
charge current when
PV is present
The first number indicates the battery voltage (V), the
second number indicates the battery charge current (A).
Battery charge
current Charge stage: Bulk, Absorption, Float or off.
Battery voltage Charge stage: Bulk, Absorption, Float or off.
Battery charge
power Charge stage: Bulk, Absorption, Float or off.
Battery temperature
The temperature is shown
or
A special message is shown:
• "---" = No sensor information
• "Err" = Invalid sensor data
Solar charger
temperature
The temperature is shown
or
A special message is shown:
• "---" = No sensor information
• "Err" = Invalid sensor data
PV current Solar array output current
PV voltage Solar array output voltage
SmartSolar Control display manual
Page 4 Operation

LCD display Menu item Description and notes
PV power Solar array output power
In addition to above menu items, the following menu items will appear when special conditions occur:
LCD display Menu item Description and notes
Warning message
"Inf" together with a number is displayed. This number
refers to an error code, see solar charger manual for the
meaning of this code.
Error message
"Err" together with a number is displayed. This number
refers to an error code, see solar charger manual for the
meaning of this code.
Remote operation "remote" is displayed.
BMS operation "bms" is displayed.
The charge stage and if PV is active is indicated by the bottom line of the display:
LCD display Description Notes
Bulk charge stage The first charge stage, the battery is between 0 and 80%
state of charge.
Absorption charge
stage
The middle charge stage, the battery is between 80% and
100% state of charge.
Float charge stage The last charge stage, the battery 100% state of charge.
3.2. History menu
The history menu shows both the daily and overall solar charger history data. It shows items such as solar yield, battery voltages,
time spend in each charge stage and past errors.
To enter and read out the historical menu:
• Press the SELECT button, while in the status menu.
• A scrolling text will be visible.
• Press the + or – button to navigate through the history items.
• When arriving at the desired history item, press the SELECT button to see the value of that item.
• If an item contains multiple values, Press + or – button to browse the various values within that item.
For the daily items it is possible to scroll back to 30 days ago (data becomes available over time), a brief popup shows the day
number.
• To go back to the main history menu, press the SETUP button.
• To go back to the status menu, press the SETUP button again.
All available history menu items are listed in below table, in the order they appear when scrolling through the items.
SmartSolar Control display manual
Page 5 Operation

Scrolling text LCD Description
YIELD TOTAL The cumulative PV yield since the last history reset.
LAST ERROR
The last 4 errors since the last history reset. Only available
if there actually were any error(s):
• E0 - Total error 0 (most recent)
• E1 - Total error 2 (shown when available)
• E2 - Total error 3 (shown when available)
• E3 - Total error 4 (shown when available)
PANEL VOLTAGE
MAXIMUM The maximum PV voltage since the last history reset.
BATTERY VOLTAGE
MAXIMUM
The maximum battery voltage since the last history reset.
YIELD The daily PV yield, available for each day for the past 30
days.
BATTERY VOLTAGE
MAXIMUM
The daily maximum battery voltage, available for each day
for the past 30 days.
BATTERY VOLTAGE
MINIMUM
The daily minimum battery voltage, available for each day
for the past 30 days.
LAST ERROR
The last 4 daily errors. Only available if there actually were
any error(s):
• E0 - Total error 0 (most recent)
• E1 - Total error 2 (shown when available)
• E2 - Total error 3 (shown when available)
• E3 - Total error 3 (shown when available)
TIME BULK Daily time spent in bulk charge stage or in ESS, in minutes,
available for each day for the past 30 days. *
TIME ABSORPTION Daily time spent in absorption charger stage, in minutes,
available for each day for the past 30 days. *
* When the charger is not active (night time) the bulk, absorption and float icons will be shown as in the table above. When
the charger is active only one icon will be shown: the icon corresponding to the actual charge state.
SmartSolar Control display manual
Page 6 Operation

Scrolling text LCD Description
TIME FLOAT Daily time spent in float charge stage, in minutes, available
for each day for the past 30 days. *
MAXIMUM POWER The daily maximum PV power, available for each day for
the past 30 days.
BATTERY
CURRENT
MAXIMUM
The daily maximum battery current, available for each day
for the past 30 days.
PANEL VOLTAGE
MAXIMUM
The daily maximum PV current, available for each day for
the past 30 days.
* When the charger is not active (night time) the bulk, absorption and float icons will be shown as in the table above. When
the charger is active only one icon will be shown: the icon corresponding to the actual charge state.
3.3. Setup menu
In the settings menu the solar charger and SmartSolar Control settings can be viewed and/or changed.
Do not change settings unless you know what they are and what the effect of changing these setting can be.
Incorrect settings may cause system problems including damage to batteries. When in doubt, seek advice
from and experienced Victron Energy installer, dealer or distributor.
To navigate the settings menu:
• Press the SETUP button for 3 seconds to enter the setup menu.
• The display will show the text “Menu” and the first menu item is shown via a scrolling text.
• Navigate to the desired setting by pressing the - or + button.
• Once arrived at the desired setting press the SELECT button to view the value the setting has been set to.
• To modify this setting press the SELECT button again, the value will now blink.
• Press the - or + button to choose the desired value.
• Press SELECT to confirm the change, the value will stop blinking, and the change is made final.
• Navigate to the next menu item, or press SETUP to return to the setup menu.
• To leave the setup menu, press the SETUP button.
Any settings change via the display or the VictronConnect App will override the rotary switch setting. Turning
the rotary switch will override settings made with the display or via the VictronConnect App.
All available settings are indicated in below table, in the order they appear when scrolling through the menu, together with a basic
description and notes for each setting. For the full description of the solar charger settings refer to the solar charger manual.
Nu
mb
er
Scrolling text LCD Desription and notes
01 POWER ON OFF This setting turns the charger in the solar charger ON or OFF.
02
MAXIMUM
CHARGER
CURRENT
Sets the maximum charge current (A).
SmartSolar Control display manual
Page 7 Operation

Nu
mb
er
Scrolling text LCD Desription and notes
03 BATTERY
VOLTAGE Sets the system voltage 12, 24, 36 or 48V.
04 CHARGE
ALGORITHM
Sets the charge algorithm.
A preset charge algorithm has been selected via the rotary switch.
This setting toggles between the preset algorithm or a USER
defined algorithm.
Only when the USER algorithm has been selected, the charge
settings in the remainder of the setup menu can be changed.
05 ABSORPTION
VOLTAGE
Sets the absorption voltage (V).
This setting can only be changed when the charge algorithm has
been set to USER in setting 4.
06 FLOAT VOLTAGE
Sets the float voltage (V).
This setting can only be changed when the charge algorithm has
been set to USER in setting 4.
08 EQUALIZATION
VOLTAGE
Sets the equalization voltage (V).
This setting can only be changed when the charge algorithm has
been set to USER in setting 4.
09 AUTOMATIC
EQUALIZATION
Sets if an automatic equalization should take place and how often
this should be. Set to OFF 0 (default) or a number between 1
(every day) and 250 (once every 250 days).
Do not equalize charge Gel, AGM, VRLA or
lithium batteries. Equalization can cause
damage to the battery if the battery is not
suitable for an equalization charge. Always
check with the battery manufacturer prior to
enabling equalization.
10 MANUAL
EQUALIZATION
Initiates a manual equalization (START, STOP).
Only perform a manual equalisation during absorption or float
charge stage, and when there is sufficient sunlight.
Press SELECT: the text START will blink, press SELECT again to
start equalisation.
The manual equalise duration is 1 hour.
To terminate the equalisation mode prematurely, enter the setup
menu and navigate to setup item 10, press SELECT: the text
STOP will blink, press SELECT again to stop equalisation.
Do not equalize charge Gel, AGM, VRLA or
lithium batteries. Equalization can cause
damage to the battery if the battery is not
suitable for an equalization charge. Always
check with the battery manufacturer prior to
enabling equalization.
11 RELAY MODE
Sets the relay function:
•0 - Relay always off.
•1 - High PV voltage, see setup items 16 and 17.
•2 - High internal temperature solar charger, above 85°C.
•3 - Battery voltage too low, see setup items 12 and 13.
•4 - Equalization active.
•5 - Error condition present.
•6 - Low internal temperature solar charger, below - 20°C.
•7 - High battery voltage, see setup items 14 and 15.
•8 - Solar charger in float or storage charge stage.
•9 - Daylight detection, solar array irradiation.
•10 - Load control. The relay switches according to load control
mode, see setting 35.
SmartSolar Control display manual
Page 8 Operation
Table des matières
Autres manuels Victron energy Moniteur

Victron energy
Victron energy BMV-700 Manuel utilisateur

Victron energy
Victron energy Blue Power BMV-602 Manuel utilisateur

Victron energy
Victron energy Blue Power BMV-602 Manuel utilisateur

Victron energy
Victron energy BMV 712 Smart Manuel utilisateur

Victron energy
Victron energy SmartSolar SCC900650010 Manuel utilisateur

Victron energy
Victron energy BMV-700H Manuel utilisateur

Victron energy
Victron energy MPPT Control Manuel utilisateur