VEVOR D-168 Manuel utilisateur

Technical Support and E-Warranty Certificate www.vevor.com/support
ELECTRIC BREAST PUMP
MODEL:D-168
We continue to be committed to provide you tools with competitive price.
"Save Half", "Half Price" or any other similar expressions used by us only
represents an estimate of savings you might benefit from buying certain tools
with us compared to the major top brands and does not necessarily mean to
cover all categories of tools offered by us. You are kindly reminded to verify
carefully when you are placing an order with us if you are actually saving half
in comparison with the top major brands.

MODEL: D-068
Have product questions? Need technical support? Please feel free to
contact us:
Technical Support and E-Warranty Certificate
www.vevor.com/support
NEED HELP? CONTACT US!
This is the original instruction, please read all manual instructions
carefully before operating. VEVOR reserves a clear interpretation of our
user manual. The appearance of the product shall be subject to the
product you received. Please forgive us that we won't inform you again if
there are any technology or software updates on our product.
ELECTRIC BREAST
PUMP

Warning-To reduce the risk of injury, user must read instructions
manual carefully.
Warning:
It means that due to a mistake,death or serious injury could result
Danger:
Indicates that due to misoperation, death and injury may occur
This product is subject to the provision of European Directive
2012/19/EC. The symbol
showing a wheelie bin crossed through indicates that the product
requires separate refuse
collection in the European Union. This applies to the product and all
accessories marked
with this symbol. Products marked as such may not be discarded
with normal domestic
waste, but must be taken to a collection point for recycling electrical
and electronic
devices
Comply with the European security certification
This product is of protection class II. That means it is equipped with
enhanced or double
insulation.
Dear customer
Thank you for using our company's products. The products you purchased
from our company
Precautions
1. Before use, remove all packaging from this product and check if the
components are complete by referring to the product manual (component
description).
2. This product is a personal product, please do not use it by more than one
person to avoid affecting your health.
3. When cleaning this product, please unplug the adapter from the power socket

and do not use bleach, chemical disinfectant solutions/tablets, steel wool,
abrasive cleaners, or corrosive liquids (such as gasoline, acetone, or
alcohol)To clean this product.
4. When disassembling or installing components such as tees, silicone horns,
bell mouths, silicone cylinders, duckbill valves, etc., caution should be
exercised and excessive force should not be used.
5. The cylinder head cannot be rinsed with water. If water enters during cleaning,
shake off the water droplets and let them dry before continuing to use.
6. During use, it is necessary to ensure that the hose is clean and free of water
droplets, otherwise it will affect the performance of the host.
7. It is recommended to use a dedicated steam sterilizer or boiling water to
disinfect the accessories that need to be disinfected. Disinfectants such as
cabinets, microwave ovens, and pressure cookers should not be used for
heating and disinfection. The main unit should not be immersed in water for
cleaning.
8. The packaging, all components, and the host are not toys, please keep them
out of reach of children.
9. Store in a cool and dry place, avoid direct sunlight, and keep away from
ignition and heat sources.
10. When breastfeeding is difficult, the body should be relaxed before
breastfeeding; When breast swelling is painful, hot compress and massage
should be done first; If you feel uncomfortable with breastfeeding or cannot
produce milk multiple times, you should consult a doctor.
11. If any parts are damaged, to avoid danger, please stop using them and send
them to our company's service center for maintenance. Do not use
accessories or components produced by other manufacturers or without our
company's permission to avoid danger.
Declaration of Conformity
This product meets the requirements of corresponding national food safety
standards. The compliance information of the "food contact materials" and their
execution standards is as follows:
Component name
material quality
Executive standards
Temperature

Tee, cylinder head, dust
cover, 180ml wide mouth
milk bottle, bottle cap
PP
GB 4806.7-2016
-10~100°C
Silicone horn, silicone
cylinder, pacifier, duckbill
valve
silica gel
GB 4806.11-2016
-10~180°C
Product Introduction
product name
electric breast pump
Model
D -1 6 8
Main materials
A B S, silicone, P P
Executive standards
QB/T 5136
Charging input voltage
5 V
Lithium battery
3 . 7 V — 4 0 0 0 m A h
Rated power
10W
Noise limit
≤ 5 0 d B ( A )
protection against electric shock
Class I
Conditions of Use
5℃~40℃,10%~90%RH
Functional characteristics
Product Features
1. Biomimetic automatic: Controlled by a microcomputer chip program, it simulates
the intermittent sucking of breast milk by infants.
2. In the "bionic" mode, the intensity is adjustable at 9 levels, while in the
"massage" mode, the intensity is adjustable at 9 levels, effectively massaging the
breasts;In the "breast suction" mode, the intensity is adjustable at 15 levels, while
in the lactation mode, the intensity is adjustable at 15 levels, imitating the speed of
the baby's sucking rhythm and the size of the baby's sucking volume.
Product features
1. The cylinder design with gas-liquid separation structure ensures no milk return
during suction.
2. Detachable liquid silicone horn, imitating ergonomic principles, has the function
of sucking, massaging, squeezing breasts, and stimulating lactation during breast
suction.

3. The control panel is designed with a touch screen, displaying the interface and
making the operation process clear at a glance.
4. The host is equipped with a built-in battery, making it easy to use during power
outages or when going out from home.
Component Description
Serial
Numb
er
Compo
nent
Name
number
material
quality
Serial
Number
Compo
nent
Name
number
material
quality
1
Dust
cover
2
PP
8
Silicone
horn
2
Silicone
2
horn
2
PP
9
Silicone
cylinder
2
Silicone
3
Tee
2
PP
10
Cylinde
r head
2
PP
4
Straight
connect
or
2
PP/TP
R
11
hose
2
Silicone
5
Connec
ting line
1
/
12
Duckbill
valve
2
Silicone
6
main
engine
1
/
13
Pacifier
kit
2
Silicone
+PP
7
180ml
wide
mouthe
d milk
bottle
2
PP

1 8 2 9 3 10 4 5
13 7 12 6 11
Attention: Please check if the components are complete before use.
Installation instructions
Reminder: Before each use, components that come into direct contact with breast
milk should be disinfected in advance: milk bottles, silicone horns, three-way
silicone cylinders, duckbill valves, and bottle caps.
Installation steps:

1. Insert the silicone horn and horn mouth in sequence before inserting the dust
cover.
2. Insert the silicone horn and horn mouth components into the tee to ensure they
are in place.
(Note: When disassembling, hold the tee with one hand and swing the trumpet
assembly up and down slightly with the other hand, and gently pull it out.)
3. Place the cylinder and cylinder head into the tee and tighten the air tight.
4. Insert the duckbill valve into the bottom milk outlet of the tee to ensure that it is
installed in place without air leakage.

5. Screw the tee assembly into the bottle.
6. Insert the straight connectors of the hoses into the cylinder head and the
relative hole positions of the host machine to ensure that they are installed in place
without air leakage and can be used.
(Note: Before inserting the straight connector into the air duct hole of the host, the
dust plug must be removed first. Do not start the host before removing the dust
plug, otherwise it will affect the service life of the host.)
Instructions for use
Preparation before use
Before use, please check and ensure that all disinfected components (parts that
come into direct contact with breast milk) are clean and free of water droplets. The
suction device is firmly connected to the host.
Before breast suction, please use a damp and hot towel to clean, compress, and
massage the breasts and areola to relax the body and relieve the pain of bloating.
Panel operation instructions

Power on/mode switching
·Tap the " " button for 2 seconds to turn on the device and enter biomimetic
mode by default.
·After turning on, the breast suction/biomimetic /massage/lactation mode can be
switched.
Night operation switching
·Press the power button to turn off the screen light; Press the power button again
and the screen light will light up.
·When the working mode is "biomimetic", "≈" lights up. When the working mode
is "massage", ". C" lights up. When the working mode is "lactation", "◆" lights up.
When the working mode is "breast suction", "(" lights up and does not display
when turned off.
·In the "bionic" mode, the intensity is adjustable in 9 levels, and the screen
displays the corresponding gear number.
·When in the "massage" mode, the intensity is adjustable in 9 levels, and the
screen displays the corresponding gear number.
·When in the "lactation" mode, the intensity is adjustable in 15 gears, and the
screen displays the corresponding gear number.
·When in the "breast suction" mode, the intensity is adjustable in 15 gears, and
the screen displays the corresponding gear number.
Ce manuel convient aux modèles suivants
1
Table des matières