Verkada AC42 Manuel utilisateur

Document
Document Details
Installation Guide V1.0 (20230111)
(V1.0 first published 20230111)
Firmware
Firmware version can be verified on
Verkada Command command.verkada.com.
2
Levels of Access Control
●Attack Level/Grade: Level 1
●Endurance Level/Grade: Level 1
●Line Security Level/Grade: Level 1
●Standby Power Level/Grade: Level 1
UL294 Performance Levels
●Attack Level: Level I
●Endurance Level: Level I
●Line Security Level: Level I
●Standby Power Level: Level I
CAN/ULC-60839-11-1
●Grade assignment: Grade I
Installation and/or maintenance of this
product shall be performed by trained
professionals only.
Caution
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.

Appendix
AC42 Compliance
FCC
Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate this equipment.
IC
Statement
This device complies with ISED’s licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d’ ISED applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes :
(1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout
brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable.
Note This equipment is for use in an indoor and a restricted access area.
3Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.

Introduction
What’s in the box
4
What you’ll need
●A working internet connection
●A smartphone or laptop
●A #2 Phillips head and power drill
●A level
Connect
Connect the AC42 to your network using the
Ethernet port located at the bottom of the
controller. Connect the AC42 power supply
into your power outlet.
Supports 100- 240VAC (50/60Hz).
After connecting the AC42 to network and
power, visit: verkada.com/start
For detailed installation instructions, visit:
verkada.com/support
●AC42 Door Controller
●Wall Mount
●Mounting Template
●AC Cable
●4x Plywood Screws
●Screwdriver
●2x Keys
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.

Introduction
5
Lock
Status LED
Status LED Behavior
Solid Orange
Controller is on and booting up
Flashing Orange
Controller is updating firmware
Flashing Blue
Controller is managing doors,
but cannot reach the server
Solid Blue
Controller is managing doors
and connected to the server
Flashing Pink
Identify
Power supply
Other LED Behavior
Door: On
Door unlocked
AUX Out: On
Relay in triggered state
REX / DPI / AUX In: On
Circuit closed
FAI: On
FAI in triggered state
AC inlet
Overview 1/2
Serial Number QR
code
AC Power LED
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.

Introduction
Overview 2/2
6
Controller highlights
1 Ports for: AUX.
2 Ports for: Doors 1 to 4. All door ports function the same.
3 Ports for: Fire Alarm Interface(FAI).
4 Ports for: Ethernet, USB, UPS, Door Tamper.
1
2
3
Status LED
Trigger lock
and current
select Door ports
AUX Ports
1
2
4
4
Ethernet USB UPS Signal Door Tamper
FAI ports
3
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.

Introduction
Recommended Testing
7
To ensure ongoing functionality of AC42, it is recommended to check the following
interfaces every 6 months:
●Short each input to its adjacent GND port and verify that LED illuminates.
●Use multimeter to confirm expected impedance across relay outputs.
○Closed across NC and COM
○Open across NO and COM
●Use multimeter to verify correct voltage is supplied at 12V AUX output, Relay Contact
outputs, and reader power outputs.
●Check the shielding cables of the readers and other AUX wiring, if any, for proper
connection to the grounding screw/s on the chassis.
●If a back-up battery is in use, follow installation, maintenance, and other safety
guidelines and recommendations from the battery manufacturer
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.

8
Introduction
AC42 Technical Specifications
Power
Consumption 60W maximum
AC Power Input 100-240VAC
50/60Hz
1.5A maximum
Inputs 2x REX dry inputs per door
1x DPI dry input per door
2x auxiliary dry inputs
Readers
1x reader port (Verkada/RS-485 or Wiegand) per door
Reader current consumption must be < 250mA per reader
Note: max of 4 readers can be powered simultaneously
Relay Outputs
1x wet or dry relay per door
Wet relay switch-selectable power:
●12V operation 700mA max
●24V operation 350mA max
Dry relay max pass-through power:
●24VDC @ 2A (resistive load)
2x auxiliary dry relays
AUX Power 1x 12V @ 250mA
Dimensions 417 x 321 x 116.25mm
Weight 6.35kg
Operating
Temperature 0°C - 50°C 5 - 90%
Humidity
Compliance FCC Part 15 Class A, ICES-3 Class A, CE, UKCA, RCM, VCCI, UL
294, CAN/ULC 60839-11-1, UL 62368-1, CSA C22.2 No. 62368-1,
IEC 62368-1, NDAA
Connectivity Ethernet: 10/100Mbps RJ-45 for network connection
USB 2.0
Included
Accessories Lock key and flat head screwdriver
Mounting Options Mounting plate and 4 wood screws
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.

Installation
Mounting 1/4
9
Use the paper mounting template from the hardware
box to get a sense of the wall space AC42 will occupy.
Use the mounting template to drill pilot holes for the
mount plate.
Use the supplied screws to install the mount plate
onto the wall.
Once attached, the enclosure will extend down
roughly 16” (~40cm), from the top of the mount plate.
The size of the enclosure is:
16.5” x 12,5” (42 x 32 cm)
Please Note Leave at
minimum 2” clearance on the
left side of the enclosure in
order for the door to open
and close without hindrance.
Please Note The supplied screws are
intended for plywood installations.
For other wall materials, ensure proper
load-bearing fasteners are used.
Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.

Installation
Mounting 2/4
Unlock and open the
enclosure door with the
supplied key. Remove
the protective
cardboard from the
inside of the door.
Remove the door by
sliding it upwards.
10 Verkada Inc. 406 E 3rd Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © 2023 Verkada Inc. All rights reserved.
Table des matières
Autres manuels Verkada Contrôleurs