VenMill Industries HYBRID 2.0 Manuel utilisateur

2.0
User’s Manual
Covers setup, getting to know your
machine, alerts & warning, repairing an
optical disc, safety & cleaning, and FAQs
Rev 1.1

2
This unit is intended to clean/repair the
following discs: Blu-Ray, CD-ROMs, Music CDs,
Data CDs, DVDs, HD-DVDs, Computer Discs,
Game Discs, Books on disc, all recordable CDs
and DVDs, and double-sided discs.
THANK YOU
For purchasing the HYBRIDTM
2.0
© 2014 VenMill Industries, Inc. All rights reserved. Under the copyright laws, this manual may not be copied, in
whole or in part, without the written consent of VenMill.
Every eort has been made to ensure that the information in this manual is accurate. VenMill is not responsible
for printing or clerical errors.
Names and designs are trademarks of VenMill Industries, Inc. Artwork and Design © 2014 VenMill Industries, Inc.
All Rights Reserved.
The maximum amount of repairs per bottle may vary based on cleaning cycle usage. See www.venmill.com for
more information.
CAUTION: Units and consumables are designed for use in specic regions. Your warranty will be voided if you
purchase the equipment and/or consumables outside of your designated region. Purchase only through Authorized
Distributors found on our website at www.venmill.com. If uncertain, please contact [email protected].
VenMill Industries, Inc
36 Town Forest Road
Oxford, MA 01540 USA
USA 800-928-0090
No. Am. 866-864-0210
www.venmill.com
SAVE ALL PACKING MATERIALS. FAILURE TO
USE PACKAGING DESIGNED FOR THIS UNIT
MAY CAUSE DAMAGE TO THE UNIT AND WILL
VOID WARRANTY. FOR MORE INFO CONTACT
SUPPORT@REFACE.COM.AU

3
READ BEFORE OPERATING EQUIPMENT
SECTION 1
Unpacking ..........................................................................................................................4
SECTION 2
Getting to Know Your Unit............................................................................................5
SECTION 3
Initial Setup ........................................................................................................................7
SECTION 4
Quick Start ....................................................................................................................... 11
SECTION 5
Modes of Operation ..................................................................................................... 12
SECTION 6
Notications.................................................................................................................... 14
SECTION 7
Standard Maintenance................................................................................................ 16
How to Replace the Bung Pads.................................................................... 16
How to Replace the Center Hub...................................................................... 17
How to Rell the Water Bottle.......................................................................... 17
How to Replace the Bung Solution Bottle .............................................. 18
When to Empty the Catch Tray ........................................................................ 19
How to Clean the Catch Tray............................................................................. 19
How to Replace the Jet Nozzle Extender ..................................................... 20
How to Unclog the Jet Nozzle Extender....................................................... 20
How to Replace the Consumable Counter Chip (C-H Chip) .................. 21
SECTION 8
Repacking ........................................................................................................................ 23
SECTION 9
Hybrid 2.0 FAQs.............................................................................................................. 25
SECTION 10
Specications.................................................................................................................. 27

4
SECTION 1: Unpacking
SAVE ALL PACKING MATERIALS. FAILURE TO USE PACKAGING DESIGNED FOR
THIS UNIT WILL CAUSE DAMAGE TO THE UNIT AND WILL VOID WARRANTY.
Parts that need to be saved are as follows:
VMI Hybrid Shipping Box | Top Cardboard Insert | Left & Right Side Packing
Foams | Protective Plastic Bag
Replacement packing materials are available for purchase from VenMill
Industries if they are discarded.
1. Open the Shipping Box.
2. Remove the Top Cardboard Insert -
which contains the machine’s starter
supplies, accessories, and support
documents.
3. Remove the Hybrid from the shipping
box.
4. Remove the Left and the Right side
packing foams.
5. Take the Hybrid out of the protective
plastic bag.

5
SECTION 2: Getting to Know Your Unit
Bung Pads
Jet Nozzle Extender
Catch Tray
Platen Assembly
Center Hub
Keypad
Pumps
Bung Solution
C-H Chip
Back Panel Door
On/O
Switch
Power
Inlet
Water

6
Operation minutes per set of supplies:
Bung Pads: 84 minutes of operation
Center Hub: 84 minutes of operation
Jet Nozzle Extenders: 500 minutes of operation
Water Bottle: 100 minutes of operation
Bung Solution: 250 minutes of operation
C-H Chip: 500 minutes of operation
Supplies for the Hybrid come in a combo pack good for 500 minutes of use. The
components of the combo pack have to be replaced at the following intervals:

7
SECTION 3: Initial Setup
1. Install Counter Chip:
Locate the RS232 port on the front left hand side
of the machine.
Take the C-H Chip, which has been provided with
your machine, and install it into this port.
The VMI Hybrid unit will recognize this chip, once
the machine is powered on.
2. Fill the Water Bottle:
Locate the Back Panel Door, on the backside
of the machine, and pull down on this door to
access the Bung Solution and Water Bottle
compartment.
Find the Water bottle, located inside this
compartment.
Remove the Water bottle from the machine and
ll as shown in the corresponding picture. Note:
This bottle can be lled with any potable water.
Also included inside of this compartment, on
the back wall are markings branded into the
back wall indicating which tube is for the Bung
Solution and which tubing is for the Water. Locate
the Water tube.
Feed the designated tube through the Water
bottle cap. Note: Make sure the tube reaches the
bottom of the bottle and make sure not to pinch
the tube.

8
3. Install Bung Solution Bottle:
Two bottles of Bung Solution have been
provided with your machine. Find the bottle of
Bung Solution which has an opening for tubing
in its cap. Note: Only one of the two Bottles of
Bung Solution contains a cap with an opening
for tubing. This cap must be saved for reuse.
Before installation, it is essential to shake this
bottle well!
Once you have shaken the bottle, unscrew the cap, and remove the internal
Safety Seal. Note: Please keep this Safety Seal! Reinstall the cap.
Also located inside of the bottle compartment, on the back side of the
machine, are markings indicating which tube is for the Bung Solution.
Locate this tube.
Feed the designated tube through the Bung Solution bottle cap. Note: Make
sure the tube reaches the bottom of the bottle and make sure not to pinch
the tube.
Close the back panel door.
Reminder: Please keep the Shipping Cap (this does not have an opening for
tubing) and the Safety Seal. Should the machine need to be sent in for servicing,
the Bung Solution bottle must be removed. To ensure that the solution will not
cure, you will need to make sure that the bottle is sealed and capped.
4. Install Power Cord:
Insert the power cord into the power inlet on the
back of the machine.
Take the other end of the power cord and plug it
into a wall outlet.
On the back side of the machine, turn the ON/
OFF switch to the ON position.(After a couple of
seconds, the Top Cover will automatically open.)
Leave the Top Cover in the open position.

9
5. Prep Bung Solution and Water Lines:
Warning: Failure to prep the Bung Solution &
Water lines will cause damage to both the disc
and the Bung Pads!
The top cover must be in the open position to
perform these steps. Have a paper towel or small
container ready, in order to catch the Bung
Solution and the Water, which will come from the
tube nozzles.
Locate the two smaller buttons, labeled“C”& “W”, on the front User Keypad.
“C” = Bung Solution & “W”= Water.
To activate the prepping process, press either the “C” or the “W” button. Note:
Both lines can be prepped at the same time.
Once the prepping process has been activated, tilt the Top Cover down
toward you, at about a 45 degree angle. (Note: Make sure that the Platen
Assembly is installed, so that solution and water does not pour directly onto
the shaft of the main motor!) This will ensure that the solution and the water
drips out of the nozzles and onto the paper towel.
Once the Bung Solution and the Water comes out of the designated tube
nozzles and there is no more air left in the lines, press the“C” and the “W” button
to stop the prepping process. Leave the Top Cover in the Open position.
6. Install the Center Hub:
Locate and remove the Lid Stopper. Let the Top
Cover gently open to its farthest position. Locate
the Hex shaped post between the two Bung
Pad holders.
Take a Center Hub and line up the hex shaped
opening on the hub with the hex shaped
post. Push the Center Hub into place. Spin the
Center Hub by hand to make sure that the hub
is installed properly. The Center Hub should
not wobble when it spins. If needed, make an
adjustment. Leave the Top Cover in the Open
position.

10
7. Install the Bung Pads:
Locate the two Bung Pad Holders.
Take one set of new Bung Pads.
Each Bung Pad has been marked on the back
side with an “L”or an “R”, to indicate which Bung
Pad should go on which Bung Pad Holder.
Note: Orientation of the machine is from the
prospective of the Operator facing the front of
the unit. The “R” (RIGHT) Bung Pad is larger in
size than the“L” (LEFT) Bung Pad.
Install each Bung Pad onto the Bung Pad
Holders. Make sure that each Buer Pad is
centered and fully seated on the Bung Pad
Holder.
Reinstall the Lid Stopper.
Caution: It is essential to keep the Top Cover in
the Open position when the machine is in the
“Stand By”mode and when the machine is not
in use! This will ensure that the Bung Pads will
not become at, which would aect the repair
process, and would cause an error message to
display. If you would like to keep the Top Cover
closed, when the machine is not in use, make
sure to remove the Platen Assembly.
Your VMI Hybrid unit is now ready to be used!
Table des matières
Autres manuels VenMill Industries Accessoires informatiques