Venen Engel Premium 12 Manuel utilisateur

OPERATING INSTRUCTIONS
ENGLISH

PRELIMINARY REMARK
Congratulations on the purchase of this device! You will enjoy your Venen Engel very much! If you are satisfied with your
Venen Engel, we would be very pleased if you submitted a review.
This guide includes details that should be taken into account by the user, to avoid risks, and to enable the safe use of the
device.
Should you have any questions about its application, its accessories, or if you have suggestions, please do not hesitate to
contact us! We are also happy to help you with any complications that develop during or after using the product.
Telephone: +49 (0) 666 17 48 91 05
Whatsapp: +49 (0) 157 359 900 46
Mail: [email protected]
Web: www.venenengel.de
HelpDesk: help.venenengel.de
BEFORE YOU GET STARTED
●Please read the operating instructions carefully before using the device.
●Keep this user manual so you can consult it, if necessary.
●Venen Engel may not be used if you suffer from certain health conditions. Please read the list of
contraindications carefully on last page.
14

STEP 1: BEFORE USE
CONNECT THE HOSE SET
AND CUFFS
Connect the tubes to the connectors on
the cuffs. Make sure the longest tube
goes to the foot air chamber.
Note: We recommend that you do not
detach the connectors after setup.
CONNECT THE TUBE SET AND THE
CONTROL UNIT
There are two clips on the side of the
multi-plug. Depress the clips then insert
the multi-plug into the control unit.
Note: Please insert the small fittings of
the multi-plug into the openings found
above the air outlets.
CONNECT THE POWER SUPPLY TO
THE CONTROL UNIT
Connect the power supply to both the
control unit and an outlet to ensure
power.
Note: To keep the device clean, we recommend wearing thin jogging pants or leggings. Keep pockets empty. Zip the cuffs
completely closed to avoid sudden opening. Be careful not to kink the tubing during use.
15

STEP 2: OPERATION
Turn the device on.
Select the run time.
Select the pressure level.
Select the program.
Customize the
program using
additional functions
(see next page).
Start the program.
16
Enable/disable the key lock.

STEP 2: OPERATION - ADDITIONAL FUNCTIONS
DEACTIVATE AIR CHAMBERS
●To deactivate individual chambers, press the number button below the chamber.
●The air chamber is deactivated once the number button beneath the chamber is no longer
illuminated.
INDIVIDUAL CHAMBER PRESSURE SETTING (INDIVIDUAL PRESSURE)
●Adjusts the desired pressure for each selected chamber.
●Activate this function by holding the button until all number buttons below the chambers start
blinking.
●Then select the desired chamber and enter the preferred pressure.
●Repeat these steps for each chamber as desired.
●Long press the button to save your settings.
●The flashing icon confirms that you successfully activated the function.
INTERVAL TIMER SETTINGS (INTERVAL)
●Set the pause duration between two message intervals.
●The interval timer starts after the hold timer of the last chamber(s) message interval of any
program has ended.
●The duration can be set from 0-50s in 10-second increments by button press.
HOLD TIMER SETTINGS (HOLD)
●Maintain the desired pressure for a specified duration in an active chamber
●The hold timer starts when the chamber target pressure is reached.
●The duration can be adjusted from 0-5s in 1-second increments by button press.
-
17

INSERT BATTERY
●Remove the battery protection insert prior to using the remote for
the first time.
●Insert a type CR2032 battery (please note that we are not allowed to include
batteries due to shipping regulations).
OPERATING THE REMOTE CONTROL
●The remote control is used in a similar way to the display unit
described on the previous pages.
STEP 2: OPERATION - REMOTE CONTROL
18

STEP 3: ENJOY THE MESSAGE
MESSAGE PROGRAMS A-H:
The air chambers in the leg cuffs are filled based on the
selected program. This creates an optimal and relaxing
gliding pressure message on both legs. Duration and
pressure, in addition to optional additional functions can
also be adjusted during the message.
19

STEP 4: STOPPING AND DISASSEMBLY
After the set time has elapsed or after pressing the off switch, remove the multi-plug from the device. If you don't feel well
during the message, you can switch the system off at any time.
Once turned off, you can open the cuffs. To quickly deflate the air chambers after use, press on the air chambers with both
hands.
The gray tube cuff connectors can be left permanently connected.
For storage, place the cuffs (incl. tubes) on top of each other. Then roll them loosely together.
The cuffs can be cleaned using a damp cloth and mild detergent. Allow the cuffs to dry thoroughly.
TROUBLESHOOTING
AIR IS ESCAPING (AUDIBLY)
1. Check the tubes and connectors for damage or kinks that could cause air to be trapped.
2. Make sure the multi-plug is seated correctly in the control unit.
20

TROUBLESHOOTING
THE DEVICE DOES NOT TURN ON
1. Make sure the power supply is seated correctly in the unit and plugged into an outlet.
2. If the device still won't turn on, remove the power supply from the device. Turn the device over and remove the fuse
holder labeled "FUSE" on the bottom of the device using a screwdriver. Check whether the fuse inside is intact.
3. If the fuse is intact, screw it fully back into the device and contact our customer service team. If the fuse is damaged,
replace it with a commercially available thin wire fuse (slow blow (TR); 3.15A; 5x20mm).
THE CUFFS INFLATE IN THE WRONG ORDER
1. Make sure the multi-plug is inserted in the control unit using the correct orientation. The multi-plug is seated correctly
if the small fittings of the multi-plug are in the openings found above the air outlets.
THE CONTROL UNIT IS UNUSUALLY LOUD
1. Unusually loud means that you're unable to carry on a conversation or relax during use or that the device's volume level
exceeds 75dB.
2. This can also happen if the security screw included during transportation has not been removed. We normally remove
the transportation security screw prior to delivery, however if your device still has one you can easily remove it yourself.
3. To do this, open the cover on the bottom then remove and dispose of the transportation screw.
21

Number of programmes 8
Number of air chaimbers 12
Weight [in kg] 5
Power output [in W] 78
Mains frequency [in Hz] 50 / 60
Voltage [in V] AC220-240
Timer setting [in min] 5-99
Pump output [in l/min] 20-25
Pressure [in mmHg] 30-240
Dimensions [in cm] 30 x 25 x 16
Protection class II/
Temperature range [in °C]
(use and storage)
10-40
Humidity [in %]
(use and storage)
30-85
Fuse T 0,315 A H
CONTENT & TECHNICAL DETAILS
Device Power plug
Multi-Plug air hose set
Cuffs
22
Remote control