Uponor Smatrix Heat Pump Integration to NIBE
products
EN Quick Guide
LEK
LEK
LEK
CD0000017

Table of contents
1 Prepare installation............................................................... 3
1.1 Uponor Smatrix Wave/Wave PLUS/Base PRO...................... 3
1.2 NIBE heat pump/indoor module.............................................. 3
2 Install heat pump integration............................................... 4
2.1 Connect heat pump/indoor module to controller..................... 4
2.2 Activate heat pump integration............................................... 4
2 | Uponor Smatrix Heat Pump Integration to NIBE products | Quick Guide

1 Prepare installation
1.1 Uponor Smatrix Wave/Wave
PLUS/Base PRO
CD0000021
Make sure the system contains one of the following product setups.
• Uponor Smatrix Wave X-165 (controller) and Uponor Smatrix
Wave I-167 (interface)
• Uponor Smatrix Wave PLUS X-165 (controller) and Uponor
Smatrix Wave PLUS I-167 (interface)
• Uponor Smatrix Base PRO X-147 (controller) and Uponor
Smatrix Base PRO I-147 (interface)
1.2 NIBE heat pump/indoor
module
input version
display version
CD0000020
Illustrations of NIBE products and and their components are subject to ©NIBE.
Make sure the NIBE heat pump/indoor module has the correct
hardware and software versions. Go to menu 3.1 in the NIBE product
and find input version (last section).
•input version must be 34 or higher.
Contact NIBE support to replace the input card if needed.
•display version must be 5539 or higher.
Update the display software using NIBE Uplink if needed.
Uponor Smatrix Heat Pump Integration to NIBE products | Quick Guide | 3

2 Install heat pump integration
2.1 Connect heat pump/indoor
module to controller
GPI
OUT
IN
CD0000018
CD0000019
-AA3-AA3 -AA3
GPI
IN OUT
5
-X7
-X6
AUX1
AUX2
AUX3
AUX4
AUX5
-X4
6
C NO
9
10
11
12
13
14
15
16
17
18
WD0000018
-AA3
Illustrations of NIBE products and and their components are subject to ©NIBE.
Warning!
Risk of electrical shock! Electrical installation and service
behind secured 230 V AC covers must be carried out
under the supervision of a qualified electrician.
To connect a compatible NIBE heat pump/indoor module to the
controller:
1. Ensure that the power is disconnected from both the controller
and the heat pump/indoor module.
2. Remove the screw and open the cover for the optional
connections compartment.
3. Route the cable via appropriate cable entries on the controller
and heat pump/indoor module.
See heat pump/indoor module manual for information about
which cable entries to use.
4. Connect controller connection terminal IN to terminal block AA3-
X4:5-6 on the heat pump/indoor module input card.
5. Connect controller connection terminal OUT to terminal block
AA3-X6:AUX (use a free AUX input) on the heat pump/indoor
module input card.
See heat pump/indoor module manual for information about
AUX inputs.
6. Optional connection heating/cooling (if available) switch
connection
Heating/cooling can be switched by either:
• The heat pump/indoor module decides when to switch
between heating and cooling (heat pump/indoor module is
master and Uponor controller is slave).
Connect controller connection terminal GPI to terminal
block AA3-X7:C-NO on the heat pump/indoor module
input card.
In the Uponor Smatrix Interface (I-147 or I-167), set
Integration > General Purpose Input (GPI) to Heating/
Cooling switch (default), and Heating/Cooling >
Operating mode to H/C Slave (default).
• An external switch is used to switch between heating and
cooling (both the heat pump/indoor module and Uponor
controller are slaves)
Connect the switch to controller connection terminal GPI,
and to the heat pump/indoor module input card.
In the Uponor Smatrix Interface (I-147 or I-167), set
Integration > General Purpose Input (GPI) to Heating/
Cooling switch (default), and Heating/Cooling >
Operating mode to H/C Slave (default). See heat pump/
indoor module manual for information about how to switch
between heating and cooling.
• Use the Uponor Smatrix Interface (I-147 or I-167) to switch
manually between heating and cooling.
7. Secure the cable properly with a cable clamp in the controller
enclosure.
8. Close and secure the lid to the optional connections
compartment in the controller.
2.2 Activate heat pump
integration
When the function is activated, the system will provide the heat pump
with temperature sensor data from Uponor system thermostats to
adjust the supply temperature. Device integration specific settings
also appear.
4 | Uponor Smatrix Heat Pump Integration to NIBE products | Quick Guide

Caution!
If Heat pump integration is deactivated make sure that
it also is deactivated in the heat pump. Otherwise it may
affect the operation of the heat pump.
Uponor Smatrix Wave/Wave PLUS/Base PRO
1
SI0000170
Integration
GPI: Heating/Cooling switch
Integration
GPI: Heating/Cooling switch
HP integration: Inactive
2
SI0000171
~10 sec
Integration
GPI: Heating/Cooling switch
HP integration: Inactive
HP integration: Inactive
ActiveInactive
HP integration
3
SI0000172
HP integration: Active
ActiveInactive
HP integration
HP integration: Inactive
ActiveInactive
HP integration
HP integration: Active
ActiveInactive
HP integration
Dynamic heatcurve: Inactive
Response: Slow
Pulse input: Inactive
HP integration
4
SI0000173
The Heat pump integration menu is normally hidden on the Uponor
Smatrix Interface (I-147 or I-167).
To activate heat pump integration :
1. Go to menu Integration.
2. Press and hold on the menu title Integration until HP
integration: inactive appears in the list.
3. Go to submenu HP integration.
4. Press Active. The function is activated in the Uponor system,
and new settings are available.
See installation and operation manual for the controller for more
information.
NIBE heat pump/indoor module
Illustrations of NIBE products and and their components are subject to ©NIBE.
To activate + Adjust (heat pump integration) in the NIBE heat pump/
indoor module:
See heat pump/indoor module manual for more information.
1. Go to menu 5.4 ― soft in/outputs located in the service menu
(hold the back button for about 7 seconds while in the main
menu).
2. Select the same AUX input as the wires are connected to.
3. Press the OK button.
4. Change the setting to + Adjust .
5. Press the OK button to confirm the change.
The new menu 1.9.11 ― + Adjust is now available. In this menu
the degree of effect on the supply temperature calculations can
be set between 0.0 and 1.0 (default 0.5) and which NIBE climate
systems will be affected. Preferably the climate system where
the underfloor heating is connected.
6. If the heat pump is heating/cooling master (decides when to
switch between heating and cooling) set AA3-X7 to indication
cooling mode.
Uponor Smatrix Heat Pump Integration to NIBE products | Quick Guide | 5

6 | Uponor Smatrix Heat Pump Integration to NIBE products | Quick Guide

Uponor Smatrix Heat Pump Integration to NIBE products | Quick Guide | 7

Uponor GmbH
Industriestraße 56,
D-97437 Hassfurt, Germany
1094087 08_2018_EN
Production: Uponor/MRY
Uponor reserves the right to make changes, without prior notification,
to the specification of incorporated components in line with its policy of
continuous improvement and development. www.uponor.com
Autres manuels pour Smatrix Wave
3
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Uponor Pompe à chaleur
Manuels Pompe à chaleur populaires d'autres marques

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Manuel utilisateur

Dimplex
Dimplex LI 16I-TUR Guide de l'utilisateur

Carrier
Carrier WSHP Open v3 Guide de configuration rapide

TGM
TGM CTV14CN018A Manuel utilisateur

Carrier
Carrier 38MGQ Series Manuel utilisateur

Kokido
Kokido K2O K880BX/EU Guide de dépannage