turbionaire Practical 12 Manuel utilisateur

DEHUMIDIFIER
DEZUMIDIFICATOR
LUFTENTFEUCHTER
DESHUMIDIFICADOR
DÉSHUMIDIFICATEUR
DEUMIDIFICATORE
Instruction manual EN RO DE ES FR IT
12
Practical


1. FEATURES 4
2. SAFETY WARNINGS 4
3. WARNING FOR DISPOSAL 5
4. TECHNICAL DATA 7
5. PRODUCT DIAGRAM 7
6. OPERATING INSTRUCTIONS 8
7. INSTALLING CASTERS 9
8. DRAINING THE COLLECTED WATER 9
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Thank you for choosing our Dehumidifier to provide you and your family with your home
comfort needs. This owner’s manual will provide you with valuable information necessary for
the proper care and maintenance of your new dehumidifier. Please take a few moments to read
the instructions thoroughly and familiarize yourself with all the operational aspects of this
dehumidifier. This unit removes unwanted moisture from the air to create a more comfortable
environment in your home or office. It can be conveniently moved from room to room within
your home.
EN:
9.. CONTINUOUS WATER DRAINAGE 10
10. MAINTENANCE 11
11. DEHUMIDIFIER STORAGE 11
12. TROUBLESHOOTING 12
12. NOTE FOR MAINTENANCE WORK 13

4
1. FEATURES
Powerful Dehumidifying Capability
Taking advantage of refrigeration technology, the dehumidifier powerfully removes
moisture from the air to decrease the humidity level of the room and keep the indoor air
dry and comfortable.
Lightweight Portable Design
The dehumidifier is built to be compact and lightweight. The casters on the bottom of the
unit make it easy to move from room to room.
Low Temperature Operation with Automatic Defrost
When the unit is running in a room temp. between 5℃ and 12℃, it will be stop to defrost
for every 30 minutes
When the unit is running in a room temp between 12℃ and 20℃, it will be stop to
defrost for every 45 minutes
Adjustable Humidistat
Reglați nivelul de umiditate dorit.
Timer On / Off
Adjust the desired humidity level by the humidistat.
Quiet Operation
The dehumidifier operates with a low noise level.
Energy Efficient
The power consumption of the unit is low.
2. SAFETY WARNINGS
When using the unit, please observe the following safety precautions:
a. Unplug the power supply cord before cleaning or storage .
b. The appliances can be used indoor but not in laundry rooms.
c. Do not set the unit close to heat-generating devices or near flammable and dangerous
materials.
d. Never put your fingers or objects into the intake or discharge ducts.
e. Do not sit or stand on the unit.
f. Discard water that has collected in the tank as required
g. Do not operate the dehumidifier in a closed area such as inside a closet, as it may cause a
fire
h. Do not sue the unit near edible items ,objects of art, or scientific materials
i. Install drain piping at a downhill grade to make sure that condensed water can be drained
continuously.
j. If the power supply cord is damaged it must be replaced by the manufacture or a
similarly qualified person in order to avoid a hazard.
k. The appliance must be positioned so that the plug is accessible.
l. Please keep a distance 20 cm around unit and the wall or other objects to ensure air
circulation

5
WARNING
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources
(for example: open flames, an operating gas appliance or an operating electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Appliance shall be installed, operated and stored in a room with a floor area larger than 4
m2.
The appliance shall be compliance with national gas regulations.
Servicing shall be performed only as recommended by the manufacturer.
The appliance shall be stored so as to prevent mechanical damage from occurring.
Any person who is involved with working on or breaking into a refrigerant circuit should
hold a current valid certificate from an industry-accredited assessment authority, which
authorises their competence to handle refrigerants safely in accordance with an industry
recognised assessment specification.
Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be
carried out under the supervision of the person competent in the use of flammable
refrigerants.
Appliance is filled with flammable gas R290.
Any repairs you need, contact the nearest authorized Service Centre and strictly follow
manufacturer’s instruction only.
m. The appliance shall be installed in accordance with local national wire regulations.
n. The appliance can not be used in public transportation.
o. This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
supervision.
p. Children should be supervised to ensure that they do not play with the appliance.
r. Appliances that are obviously damaged must not be operated.
3.WARNING FOR DISPOSAL
It is prohibited to dispose of this appliance in domestic household waste.For
disposal there are several possibilities
a. Do not dispose this product as unsorted municipal waste. .Collection of such
waste separately for special treatment is necessary.

6
b. The municipality has established collection systems,where electronic waste can
be disposed of at least free of charge to the user.
c. The manufacturer will take back the old appliance for disposal at least free of
charge to the user.
d. As old products contain valuable resources. They can be sold to scrap metal
dealers.
Wild disposal of waste in forests and land scapes end angers your health when
hazardous substances leak into the ground-water and find their way into the food
chain.Meaning of crossed out wheeled dustbin.Do not dispose of electrical
appliances as unsorted municipal waste,use separate collection facilities.contact
you local government for information regarding the collection systems available.If
electrical appliances are disposed of in landfills of dumps. Hazardous substances
can leak into the groundwater and get into the foodchain,damaging your health and
well-being.
This marking indicates that this product should not be disposed with other household
wastes throughout the EU. To prevent possible harm to the environment or human health
from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse
of material resources. To return your used device, please use the return and collection
systems or contact the retailer where the product was purchased. They can take this
product for environmental safe recycling.

7
MODEL PRACTICAL 12
Dehumidification capacity
Power supply
Power consumed
Noise level
Water tank capacity
Maximum refrigerant capacity
Net weight
Minimum room size
Size
12L/day (30°C, 80%)
AC220-240V/50Hz
210W/1A
46 dB
2 liters
R290/45g
9.5 Kg
4 m2 (area)
270x205x405 mm
4.TECHNICAL DATA
The dehumidification capacity is rated at a room temperature of 30℃ with a relative
humidity of 80%. If specifications are improved after this pointing, the product
nameplate will reflect the new specifications. The operational temperature is in the
range of 7℃ to 35℃ and max relative humidity of 80%. If the room temperature is
outside of this range, the unit will not operate normally. GWP value of R290 refrigerant
is 3.
5.PRODUCT DIAGRAM
1. Top panel
2. Supply cord
3. Filter box
4. Water Tank
5. Caster
6. Base
7. Back Shell
8. Front Shell

8
The indicator features 3 functions:
1. when the unit is plugged in, it will indicate the room humidity level.
2. when you set the humidity, it will indicate the humidity that you have selected
3. when you program the time for the unit to turn on and off, it will show the hours.
4. When the environment humidity is lower than 35%, it will show 35
5. When the environment humidity is higher than 95%, it will show 95
6.OPERATING INSTRUCTIONS
1. POWER
2. SETĂRI
3. DISPLAY
4. TIMER
5. VITEZĂ
OPERATING INSTRUCTIONS
1. The buzzer will buzzing when power on, and the machine will be standby, the POWER
indicator will be green. The POWER light can be used as the indicator light for WIFI
distribution when the machine is powered off.
2. Press button once to start operation. Press it again to stop operation.
3. Press bottom to adjust fan speed between high and low, and corresponding indicator
light will on at the same time.
4. Press to change the set value of humidity as follows:
By pressing to change the humidity setting value, the humidity setting range is 40% ~
80% and the interval is 5%.HUM indicator light will turn on when humidity is set, and HUM
light will turn off when humidity is set for 5 seconds.
Displays ambient humidity. After a period of working,when environment humidity is lower
than the selected humidity by 2%, compressor will stop and fan stops working 3 mintues
later;When environment humidity is equel to or higher than the selected humidity by 2%,
compressor will restart ,which means 3-minute compressor protection time`s over.
5. Press button can be timer setting:
when pressed again, and the time LED light will be on, continuously pressing the
key, will show from 01-02... to 24 - 00 as a cycle. The timer setting in power off status
is for the that unit to turn on, and the timer setting in power on status is for the unit to turn
off. The timer function/setting will be cancel everytime when artificially switch the unit
or when water fulled.

9
a. Take out the casters
Pull out the tank, find 4 casters from the
water tank, then take out the casters and
close the water tank.
b. Remove the rubber feets
Incline Turbionaire Practical 12, and
remove the 4 rubber feets from the
base.
c. Installing the casters
The castor is inserted into the mounting hole of the chassis castor, and then pressed by
hand to push the castor in the vertical direction of the chassis until the castor is in place.
8.DRAINING THE COLLECTED WATER
When the drainage tank is full, the tank full indicator light will turn on, the operation
will stop automatically and the buzzer will beep 15 times to alert the user, that the
water need to be emptied from the drainage tank.
7.INSTALLING CASTERS
Emptying the Drainage Tank
a. Lightly press on the sides of the tank
with both hands and pull the tank out
gently..
b. Discard the collected water

10
NOTE
a. Do not remove the float from the water
tank. The water full sensor will no
longer be able to detect the water level
correctly without the float and water
may leak from the water tank.
b. If the drainage tank is dirty, wash it with
cold or lukewarm water. Do not use
detergent, scouring pads, chemically
treated dust cloths, gasoline, benzene,
thinner, or other solvents, as these can
scratch and damage the tank and cause
water leakage
c. When replacing the drainage tank, press
the tank firmly into place with both hands.
If the tank is not positioned properly, the
“TANK FULL” sensor will be activated, and
the dehumidifier will not operate.
9.CONTINUOUS WATER DRAINAGE
The unit features a continuous drainage port .Using a plastic pipe (with an inner diameter
of 10mm) inserts into drain hole (on intermediate plate), reach out from side of water
tank, install it in place, and arrange the drain pipe.
The water in the drainage tank can be continuously drained out from the continuous port
on the unit.
Table des matières
Langues :
Autres manuels turbionaire Déshumidificateur

turbionaire
turbionaire SENSO 12 Manuel utilisateur

turbionaire
turbionaire SMART 16 eco Manuel utilisateur

turbionaire
turbionaire SMART 8eco Manuel utilisateur

turbionaire
turbionaire PRO 50 Manuel utilisateur

turbionaire
turbionaire PRO 50N Manuel utilisateur

turbionaire
turbionaire PRO 90N Manuel utilisateur

turbionaire
turbionaire EPI 12 Manuel utilisateur

turbionaire
turbionaire Smart 10 Eco Manuel utilisateur