Maintenance
2023-11 2023-11
EN
Mounting the strainer basket
5. Replace the strainer basket Cin the inlet valve. Ensure that the filter
basket is entirely submerged and sits evenly with the valve body.
6. Make sure that the protective cap gasket is correctly located. Screw
the protective cap Bon the inlet valve with a spanner.
7. Turn the inlet and outlet valve handle A to the open position.
Disassembly of the inlet valve
3. Loosen the protective cap Bon the inlet valve with a spanner.
Let the gasket remain in the protective cover.
4. Remove the filter basket Cand clean it and the protective
cap with water.
Before starting cleaning of the inlet valve,
ensure that:
1. The inlet and outlet valve handle A is in the closed position.
2. The TTM NoXygen® is turned off or the the main power is isolated.
A
BC
Cleaning the filter basket of the inlet valve
Maintenance of TTM MAG 54
A
A
Inlopp Utlopp
!WARNING
If TTM NoXygen®is installed in a heating system then hot
pressurised system fluid may leak out when the protec-
tive cap B is unscrewed.
A
A
Inlet
Inlet
Outlet
Outlet
Cleaning the particle lter
1. Switch off both TTM NoXygen®and the main
power.
2. Close both inlet valves 1.
3. Install hose 6on the hose connector.
4. Empty the magnetite filter by opening the
drain valve 3. Leave the water to run until the
housing is empty of water.
5. Unscrew the bottom insert 4.
6. Unscrew the magnet insert 2 (see image 1).
7. Clean the particle filter 5and other parts
with lukewarm water.
8. Screw the magnet insert back in place 2.
9. Ensure the particle filter 5 and the O-ring
are correctly installed and screw the bottom
insert 4into the housing.
10. Close the drain valve 3.
11. Open both inlet valves 1.
12. Start TTM NoXygen®.
Cleaning the magnetite trap
1. Switch off both TTM NoXygen®and the
main power.
2. Close both inlet valves 1
(see image 2).
3. Install hose 6on the hose connector.
3. Unscrew the magnet insert 2.
4. Empty the particle trap by opening
the drain valve 3. Leave the water to run
until the housing is empty or until the fluid
is clear and without contaminants.
5. Close the drain valve 3and screw the
magnet insert back in place 2.
6. Open both inlet valves 1
(see image 2).
7. Start TTM NoXygen®.(Image 1)
TTM MAG 54 should be inspected and cleaned regularly, at least
twice per year. The intervals depend on the quantity of particles and
magnesite in the system fluid. If you know the system fluid is very dirty,
the filter should be inspected and cleaned more often. One sign that
TTM MAG 54 requires cleaning is, for example, that TTM NoXygen®
runs for long intervals exceeding 3 minutes “pump start to pump start”
(see Operating and maintenance instructions for TTM NoXygen®).
(Image 2)
24
5
1
6
1
3
6
3
Strong magnetic
field
Can affect
pacemaker/ICD Risk of pinching
Also be aware that the
magnet may interfere with
electronic equipment and
pacemakers.
TTM NoXygen® C650
Installation, operating and maintenance instructions
7
TTM Energiprodukter AB
Slöjdaregatan
1
|
393
66
Kalmar
|
Sweden
|
T
el.
+
46
480-41
77
40
|
[email protected] |
www
.ttmenergi.se
For latest updates visit www.ttmenergi.se.