TST TM-507 Manuel utilisateur

Wireless Tire Pressure and Temperature
Monitoring System Instrucon Manual
Model #: TM-507 Wide Screen Display
507 Flow-through and Cap Sensors
Thank you for purchasing the TST Tire Pressure Monitoring
System. With minimal care, your new TPMS will
provide reliable service for many years. Please read and
understand the informaon contained within this manual.
Keep this manual for future reference.
Telephone: 770.889.9102
Website: www.tsruck.com
TST-Doc-507 WSD Manual-(A)

INDEX
Page 1 - Sensor Features
Page 1 - Display Features
Page 2 - System Components in Kit
Page 3 - Display Controls
Pages 4 - 7 - Programming Sensor Codes Into the Display
- Automac Code Learning (Opon #1)
- Pressure Coding (Opon #2)
- Manual Coding (Opon #3)
Page 8 - Sensor Installaon - Flow-through
Page 9 - Sensor Installaon - Cap
Page 9 - Display Installaon
Page 10 - Display Buons
Pages 10 - 11 - Parameter Sengs (Pressure & Temperature)
Page 12 - High Temperature and High Pressure Sengs
Page 13 - Low Pressure Alarm Sengs
Page 14 - Restore Display Factory Parameters
Page 14 - Display Alerts - Out of Parameter/Fast Leaks
Page 15 - Display Alerts - Sensor Low Baery Alert
Pages 15 - 16 - Other Funcons
Pages 17 - 18 - Replacing the Flow-through Sensor Baery
Page 19 - Replacing the Cap Sensor Baery
Page 20 - Troubleshoong Tips
Pages 21 - 24 Common Quesons
Page 25 - Repeater
Page 26 - Sensor Specicaons
Page 27 - Display Specicaons
TST-Doc-507 WSD Manual-(A)

1
SENSOR FEATURES
1. The sensors easily install on the valve stem.
2. Sensors are water resistant.
3. Pressure and temperature data is read every two (2) minutes.
4. Removal of a sensor (0 lbs. pressure) will shut o the sensor
baery.
5. The sensor baeries last approximately one (1) year and are
user replaceable.
6. Tire leaks and high temperatures are detected quickly.
7. Tires can be inated without removing the sensor.
8. Each sensor has a unique, six (6) digit code for programming.
9. Sensors feature an an-the design using the included hex
screws.
DISPLAY FEATURES
1) Large, wide screen LCD display of pressure and temperature.
2) Opons for Color or Monochrome screen.
3) Sucon cup mount included.
4) Integrated lithium baery that is rechargeable with provided
cord.
5) Wake-up acvaon of monitor when in moon.
6) Automac monitor illuminaon in dark condions.
7) Programmable high and low pressure alarm thresholds.
8) Programmable high temperature alarm.
TST-Doc-507 WSD Manual-(A)

2
9) Visual and audible warning alarms when temperature or
pressure exceeds thresholds.
10) Mulple pressure units: PSI, BAR.
11) Selectable temperature unit: °C or °F.
12) Program up to 110 res.
13) Tire pressure and temperature is displayed simultaneously
for quick viewing of each re.
14) The trailer res can be electronically removed from the
screen when not towing.
15) The towing vehicle res can be electronically removed from
the screen when parked.
16) Push buon programming.
17) A fully charged display will connuously operate 5-7 days on
baery power.
18) Temperature and pressure sengs are congured “per axle.”
SYSTEM COMPONENTS IN KIT
Suction Cup Mount
Extra “O” rings
Power AdapterColor Display
Repeater
TST-Doc-507 WSD Manual-(A)

3
Pressure Unit: BAR or PSI, user-selectable temperature unit:
C° or F°, user-selectable.
Cap WrenchesFT Hex Wrenches
Flow-through Sensors Cap Sensors
DISPLAY CONTROLS
or
Display Holder
GO
SET
BACK
TST-Doc-507 WSD Manual-(A)

4
PROGRAMMING SENSOR CODES INTO THE DISPLAY
Note: Your sensors will begin reading as soon as they
are coded into the display. Once you go back to the
main screen by pushing the “BACK” buon twice,
you may hear an alarm and see a pressure reading
of “0”. Simply press the (+) buon quickly to silence
the alarm.
Note: It is recommended to label each sensor
rst with the provided numbering code sckers,
similar to the following paern, before you code
the sensors. This allows you to know which sensor
is programmed to which re posion. You can also
write in your sensor number paern.
Or use your own numbering paern:
TST-Doc-507 WSD Manual-(A)

5
AUTOMATIC CODE LEARNING (opon #1)
Note: Code all the sensors to the display BEFORE screwing
them onto the re valve stem unless otherwise noted.
1. Push and hold the “SET” buon unl it beeps. You are
now in the programming mode. The “HI PRESSURE SET”
parameter will blink at the boom of the screen. Push
the (+) buon and scroll through the parameters unl
“LEARN ID” appears.
2. Quickly press and release the “SET” buon. The rst
re on the display will blink. If you want to program a
dierent re, press the (+) buon to move to the correct
re. Push the “SET” buon again and “FFF FFF” will ash.
Put the sensor for that re posion next to the display
and press the “GO” buon. The display will capture
the sensor code and show it on the screen. Again, push
and release the “SET” buon to save the code to that
posion. If a double beep is heard, try pressing the “GO”
buon again. When coded correctly, a single beep will be
heard and a six (6) digit code will be shown.
3. Use the (+) buon to move to the next re posion you
want to program. Again, press the “SET” buon and
“FFF FFF” will blink. Put the sensor for that re posion
next to the display and press the “GO” buon to capture
the sensor code. Press “SET” again to save.
4. When you are nished programming all of your sensors,
press the “BACK” buon to return to the parameter
at the boom of the screen. Use the (+) or (-) buons
to scroll to another parameter, if necessary. If nished
programming, press the “BACK” buon again to go to
the Main Screen. (Your sensors will begin reading “0”
pressure and will alarm. Press the (+) buon to silence
the alarm while you connue your set-up).
TST-Doc-507 WSD Manual-(A)

6
Note: To delete a single sensor code:
Press the “SET” buon unl it beeps (approx. 3 seconds). Push
the (+) buon and scroll through the parameters unl “LEARN
ID” appears. Press and release the “SET” buon. Use the (+) or (-)
buons to scroll to the re you wish to remove. Press the “Set”
buon to select that re. It will start ashing. Press the “Back”
buon for 3 seconds. You will hear 3 beeps. The code will change
to “FFF FFF” which will be ashing. Press “SET” once. The ashing
will stop and the ID code will be deleted.
Note: To delete all of the re codes:
Press the “BACK” buon for 6 seconds. You will hear 6 beeps.
“DEL ALL” will appear on the screen. Press “SET” once. You will
hear one beep. “FFF FFF” will appear. All ID codes are deleted.
Note: When in the coding mode, the display will me-out within
approximately one (1) minute if no buons are pushed. At that
point, you will have to start the coding process again.
Note: Be sure the sensor being coded is at least two feet away
from the other sensors.
PRESSURE CODING (opon #2)
1. Be sure your sensors are numbered. Screw the sensors
partly onto each valve stem in the order you numbered
them. Do NOT screw them down far enough to hear air
hissing out.
2. Push the “SET” buon unl it beeps. You are now in the
programming mode. The “HI PRESSURE SET” parameter
will blink at the boom of the screen. Push the (+) buon
and scroll through the parameters unl “LEARN ID”
appears.
3. Quickly press and release the “SET” buon. The rst
re on the display will blink. If you want to program a
TST-Doc-507 WSD Manual-(A)

7
dierent re, press the (+) buon to move to the correct
re. Push the “SET” buon again and “FFF FFF” will ash.
4. Tighten the sensor down on the corresponding re valve
stem. The ID code will display and ash.
5. To save the ID code seng. Press “SET” once. It will beep
and sensor code is saved.
6. To remove the ID code seng, Press “BACK” once.
“FFF FFF” will re-appear. The seng will not be saved.
7. Press “BACK” twice to return to the main screen.
MANUAL CODING (opon #3)
Note: This method is mainly used to program sensor codes from
an old monitor to a new monitor if you do not have the sensors
available.
1. Push the “SET” buon unl it beeps. You are now in the
programming mode. The “HI PRESSURE SET” parameter
will blink at the boom of the screen. Push the (+) buon
and scroll through the parameters unl “SET ID” appears.
2. Quickly press and release the “SET” buon. The rst re
on the display will blink. If you want to program a dierent
re, press the (+) buon to move to the correct re. Push
the “SET” buon again and the rst digit of “FFF FFF” will
ash. Press the (+) buon to select the correct number
or leer. Press “GO” to move to the next posion. Press
the (+) buon to change to the correct number or leer.
Connue this procedure unl all six digits are changed.
3. Press “SET” once to save the new codes. You will hear a
beep and the code will stop ashing.
TST-Doc-507 WSD Manual-(A)

8
4. To stop the coding for any posion, Press “BACK” once.
“FFF FFF” will reappear. No sengs will be saved.
5. Press “BACK” twice to return to the main screen.
SENSOR INSTALLATION - Flow-through Sensor
1. Be sure the an-the allen set screw at the sensor base is
not screwed in as to impede screwing the sensor onto the
valve stem.
2. Screw the correctly marked sensor onto the valve stem
for that re posion. Tighten the sensor unl the air stops
leaking and the sensor booms-out on the valve stem.
Then give it a slight twist to seat it. Do Not Overghten!
3. Using the provided small allen wrench, ghten the set
screw onto the valve stem. This will prevent the sensor
from being removed. If necessary, you can put the screw
into the second screw hole to allow access by the allen
wrench if your rim is in the way. Keep the wrench in a safe
place for future use.
4. You can now inate or deate the re through the 507FT
sensor without removing it.
TST-Doc-507 WSD Manual-(A)
Autres manuels pour TM-507
2
Ce manuel convient aux modèles suivants
1
Table des matières