4
AUTOMATIC CODE LEARNING (opon #1)
Note: Code all the sensors to the display BEFORE screwing
them onto the re valve stem unless otherwise noted.
1. Push and hold the “SET” buon unl it beeps. You are
now in the programming mode. The “HI PRESSURE SET”
parameter will blink at the boom of the screen. Push
the (+) buon and scroll through the parameters unl
“LEARN ID” appears.
2. Quickly press and release the “SET” buon. The rst re
on the display will blink. If you want to program a dierent
re, press the (+) buon to move to the correct re. Push
the “SET” buon again and “FFF FFF” will ash. Put the
sensor for that re posion next to the display and press
the “GO” buon. The display will capture the sensor
code and show it on the screen. Again, push and release
the “SET” buon to save the code to that posion. When
coded correctly, a single beep will be heard and a six (6)
digit code will be shown.
3. Use the (+) buon to move to the next re posion you
want to program. Again, press the “SET” buon and
“FFF FFF” will blink. Put the sensor for that re posion
next to the display and press the “GO” buon to capture
the sensor code. Press “SET” again to save.
4. When you are nished programming all of your sensors,
press the “BACK” buon to return to the parameter
at the boom of the screen. Use the (+) or (-) buons
to scroll to another parameter, if necessary. If nished
programming, press the “BACK” buon again to go to
the Main Screen. (Your sensors will begin reading “0”
pressure and will alarm. Press the (+) buon to silence
the alarm while you connue your set-up).
TST-Doc-507 WSD-M Manual-(C)