UMD PSU-22 10 V4.0
6.0 The Internal Power Supplies
These are Mean Well SP-300 Series units. In the event of a failure the faulty item should be returned
to TSL for replacement.
The user should not attempt any repairs as this voids the PSU manufacturer’s warranty.
Manufacturer’s Specification Model SP- 300-24
DC Output Voltage 24V
Output Voltage Tolerance 1%
Output Rated Current 12.5A
Output Current Range 0 – 12.5A
Ripple and Noise 150mV pk-pk
Line Regulation 0.2%
Load Regulation 0.5%
DC Output Power 300W
Efficiency 86%
DC Voltage Adjustment 20 ~ 26.4V
Input Voltage Range 88264VAC 4763Hz; 124~370VDC
AC Current 4A/115V, 2A/230V
Power Factor 0.9/100240VAC
Inrush Current 18A/115V 36A/230V
Leakage Current 1mA/240VAC
Overload Protection 105135% Type: Pulsing Hiccup Shutdown Reset:
Auto Recovery
Over Voltage Protection 27.6-32.4V
Fan Control Over Temp Protect. RTH1 or RTH250C Fan On, 45C Fan Off
70C Output Shutdown
Temp. Coefficient 0.03%/C (050C)
Setup, Rise, Hold up Time 1.5s, 50ms, 20ms
Vibration 10500Hz, 2G 10min./1cycle, Period for 60min each
axis
Withstand Voltage I/P-O/P:3KVAC I/P-FG: 1.5KVAC
O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:500VDC / 100Mohms
Working Temp. Humidity -10C-+50C (Refer to O/P de-rating Curve), 20%-90%
RH
Storage Temp. Humidity -20C+85C, 10%95% RH
Dimensions 215*115*50mm Case 912
Module weight 1.2Kgs
Safety Standards UL1950, TUV EN90950 Approved
EMC Standards CISPR22 (EN55022), IEC1000-4-2,3,4,5,6,8,11
IEC1000-3-2 Verification
Notes:
1. All parameters are specified at 230V I/P, rated load, 25C, 70% RH ambient
2. Ripple and noise are measured at 20MHz using a 12” twisted pair terminated with a 0.1uF and 47uF
capacitor.
3. Line regulation is measured from low line to high line at rated load.
4. Load regulation is measured for 0% to 100% rated load.