Total Control DMS-OUT Manuel utilisateur

Universal Remote Control
DMS-OUT
Owner’s Manual
www.UniversalRemote.com

Universal Remote Control
DMS-OUT Owner’s Manual
Overview
The DMS-OUT allows 3rd party devices access to the streaming sources in
the DMS Audio Network. For example, this device is the perfect solution for
adding any new/existing 3rd party AVR, soundbar, or other audio device to
the DMS Audio Network.
Online Help:
www.urccontrolroom.com
For software downloads, training materials, and frequently asked questions.
Contact Support:
Total Control is a URC product sold through Authorized Dealers, for
questions or assistance contact you Custom Installer/Programmer (write in
the company name, email, and contact info):
or URC Technical Support at: [email protected]
Universal Remote Control, Inc.
500 Mamaroneck Ave
Harrison, New York 10528
Toll Free: (800) 901-0800
Main: (914) 835-4484
Table of Contents
Features and Benefits.........................................1
Parts & Pieces......................................................1
Requirements......................................................1
Rear Panel............................................................2
Top Panel & LED States......................................4
Bottom Panel.......................................................5
Wiring the DMS-OUT..........................................6

Page 1
Features and Benefits
The DMS-OUT is loaded with features to provide the perfect audio experience. Enjoy features such as:
●3rd Party Audio Device Integration
DMS-OUT grants 3rd party devices the ability to use sources that are available in the DMS Audio Stream.
●Audio Sensing Capability
The DMS-OUT, similar to the URC Audio Sensor (SEN-AUD), can detect an audio signal which can then trigger n activity (macro).
●Flexible Power Source
Use the supplied 5V DC power adapter or take advantage of the DMS-OUT’s PoE (Power Over Ethernet) capability using a CAT 5/6 wiring.
DMS-OUT Owner’s Manual
Parts & Pieces
Contained within the DMS-OUT box:
1. DMS-OUT Preamplifier Device
2. 5v DC Power Adapter
3. Wall Mount and 4x Screws
Requirements
As with all Total Control products, the DMS-OUT is not a
plug-and-play device. It requires programming by a
certified Total Control installer in order to work properly.
Be sure the system contains the following:
●MFS-8 or MFSPOE-8
●MRX-10 or MRX-8 Master System Controller
●URC User Interface (TRC-1080, TKP-7000, etc.)

Page 2
DMS-OUT Owner’s Manual
Rear Panel:
5V DC Input:
Provides power to the DMS-OUT. PoE may be used
as a substitute.
Analog Input:
Standard RCA (analog) connector.
Digital Input - Optical:
This input uses standard S/PDIF OPTICAL TOSLINK
connector.
Note: The DMS-OUT converts Dolby Digital 5.1/DTS 5.1
to a DMS Stream.

Page 3
LAN Port:
This 10/100 Ethernet port supports PoE and sends
the URC Audio stream through the local network,
this is also how the DMS-OUT receives commands
and sends audio.
Note: The DMS-OUT does not support Wi-Fi
Digital Input - Coax:
Standard RCA (analog) connector, this receives
bitstreams of audio data.
Note: The DMS-OUT converts Dolby Digital 5.1/DTS 5.1
to a DMS Stream.
DMS-OUT Owner’s Manual

Page 4
DMS-OUT Owner’s Manual
Top Panel & LED States:
There are three (3) LED lights at the top of the DMS-OUT which can provide users with basic troubleshooting information.
Status LED
●Off
Unit has not been programmed with a Total Control file.
●Yellow
Unit has been programmed with a Total Control file; however, is not creating
a DMS Audio Stream.
●Blue
Unit has been programmed with a Total Control file and is creating a DMS
Audio Stream through the network.
Power LED
●Off
Unit is not receiving power.
●Blue
Unit is receiving power via 5V DC adapter or PoE.

Page 5
DMS-OUT Owner’s Manual
Network LED
●Off
Unit is not connected to the local area network and cannot send/receive data.
●Blinking Green
Unit is connected to the local network, but has not received an IP address.
●Green
Unit is connected to the local network and has an IP address.
Bottom Panel
Located beneath the DMS-OUT is a Reset button. The Reset button is recessed so a
paperclip or something similar is required to press. This button allows for:
●Rebooting the DMS-OUT
A momentary press of the Reset button reboots the DMS-OUT, similar to
unplugging it from the power supply.
●Factory Default
Pressing and holding the Reset button for ten (10) seconds or longer, factory
resets the DMS-OUT to its factory state. The DMS-OUT requires re-programming
after this has been performed.

Page 6
DMS-OUT Owner’s Manual
Wiring the DMS-OUT
In order for the DMS-OUT to provide the best possible experience, it must be first wired correctly then programmed by a Total Control Certified
Installer. Follow these steps to prepare the DMS–IN for programming:
1. Power the DMS-OUT with the supplied 5V DC adapter OR PoE using the LAN port (see below)
2. Connect and Ethernet cable from the LAN 10/100 port to an MFS-8/MFSPOE-8
●The 5V DC adapter is not required when using PoE
3. Connect the DMS-OUT to a 3rd party device via Analog or Digital that is to be a part of the DMS Audio Stream
Additional set up is required via the URC Accelerator software. Contact a Certified Total Control Installer to properly configure the DMS-OUT to a
new or existing system.
OR
Only one source can be used at a time, further audio
adjustments can be made from within Accelerator.

Specifications
Microprocessor: Cortex-A5 600MHz
Memory: 128MB NAND, 128MB RAM
Network: One 10/100 Ethernet port (PoE)
Weight: 5.8oz
Size: 4.6” x 4.6” x 1.2”
Power: Standard PoE Injector or PoE Switch (purchased separately), DC 5V/1A
Page 7
DMS-OUT Owner’s Manual

Page 8
Limited Warranty Statement
1. Limited Warranty and Disclaimers
Universal Remote Control, Inc. (“URC”) warrants that the URC equipment shall be
free from defects in material and workmanship under normal usage for one (1)
year from purchase when such is purchased from URC. This limited warranty is
valid only in the United States of America. URC warrants that the software will
substantially conform in any material respect to its functional specifications at the
time of delivery. URC SHALL NOT BE LIABLE FOR OPERATIONAL, TECHNICAL OR
EDITORIAL ERRORS AND/OR OMISSIONS MADE IN THE URC DOCUMENTATION.
URC DOES NOT WARRANT THAT THE URC SOFTWARE IS BUG-FREE OR ERROR
FREE OR THAT THERE ARE NO ERRORS/BUGS IN THE URC SOFTWARE.
URC warrants that at the time of purchase the URC equipment and the URC
software complied with all applicable regulations and policies of the Federal
Communications Commissions (“FCC”) regarding electromagnetic interference
caused by electronic/computing devices and to the extent that the URC
equipment and/or the URC software fails to so comply, URC shall, at its own
expense, take all reasonable measures to promptly cause such to comply.
URC equipment purchases from other than an authorized URC dealer or
distributor are without warranty.
THIS LIMITED WARRANTY DOES NOT COVER TECHNICAL ASSISTANCE FOR
HARDWARE OR SOFTWARE USAGE EXCEPT AS EXPRESSLY PROVIDED FOR
HEREIN, THE EQUIPMENT, SOFTWARE AND DOCUMENTATION OF URC ARE
SUPPLIED “AS IS” WITHOUT ANY WARRANTY, EXPRESS, STATUTORY OR IMPLIED,
OF ANY KIND. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, URC
EXPRESSLY DISCLAIMS ALL WARRANTIES, EXPRESS, STATUTORY OR IMPLIED,
INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY AND
DMS-OUT Owner’s Manual
Table des matières