PREPARE THE MACHINE
PREPARE THE MACHINE
1. Power off the machine and the PathPilot controller.
a. Push in the machine's red Emergency Stop button, which removes power to motion control.
b. From the PathPilot interface, select Exit.
c. Turn the Main Disconnect switch to OFF on the side of the electrical cabinet.
2. Close the enclosure doors.
NOTICE! This procedure requires you to drill four holes into the enclosure. If the enclosure's right door is
open, there's a risk that you'll drill into it.
Remove the Right Side Window
To make it easier to install the mount arm, we recommend removing the right side window from the
enclosure. Loosen the screws on the vertical window retainers, and slide the window out of the right side
panel. Set the window aside.
Remove the Operator Box
1. Remove the Emergency Stop cable from the operator box.
2. Remove the four screws that secure the operator box to the machine stand using a 3 mm hex wrench.
Discard the operator box.
3. Put the four screws from the operator box back on to the machine stand.
INSTALL THE MOUNT ARM
1. Print the drill template provided in this document. To verify that the template printed at the correct size, use
a ruler to measure the 1 in. scale on the template. If the template is incorrectly sized, adjust your printer
settings and try again.
2. Cut out the drill template along its edges.
3. Find the operator console's mount arm.
4. Put the drill template on the mount arm's top bracket. Then, verify that the holes on the bracket align with
the holes on the drill template. If they don't, trace the correct hole pattern on to the drill template.
Page 4
©Tormach® 2022
Specifications subject to change without notice.
tormach.com
TD10715: Installation Guide: PathPilot Operator Console for 770 (0822A)