LCD Module User Manual LMT056DIDFWD-ABB
Document Name: LMT056DIDFWD-ABB-Manual-Rev0.3
Page: 10 of 14
8.1.4 Command Table
0x00 nop No operation
0x01 soft_reset Software Reset
0x0A get_power_mode Get the current power mode
0x0B get_address_mode Get the frame buffer to the display panel read order
0x0C Reserved Reserved
0x0D get_display_mode The SSD1963 returns the Display Image Mode.
0x0E get_tear_effect_status Get the Tear Effect status
0x0F Reserved Reserved
0x10 enter_sleep_mode Turn off the panel. This command will pull low the GPIO0. If GPIO0 is
configured as normal GPIO or LCD miscellaneous signal with command
set_gpio_conf, this command will be ignored.
0x11 exit_sleep_mode Turn on the panel. This command will pull high the GPIO0. If GPIO0 is
configured as normal GPIO or LCD miscellaneous signal with command
set_gpio_conf, this command will be ignored.
0x12 enter_partial_mode Part of the display area is used for image display.
0x13 enter_normal_mode The whole display area is used for image display.
0x20 exit_invert_mode Displayed image colors are not inverted.
0x21 enter_invert_mode Displayed image colors are inverted.
0x26 set_gamma_curve Selects the gamma curve used by the display panel.
0x28 set_display_off Blanks the display panel
0x29 set_display_on Show the image on the display panel
0x2A set_column_address Set the column address
0x2B set_page_address Set the page address
0x2C write_memory_start Transfer image information from the host processor interface to the
SSD1963 starting at the location provided by set_column_address and
set_page_address
0x2E read_memory_start Transfer image data from the SSD1963 to the host processor interface
starting at the location provided by set_column_address and
set_page_address
0x30 set_partial_area Defines the partial display area on the display panel
0x33 set_scroll_area Defines the vertical scrolling and fixed area on display area
0x34 set_tear_off Synchronization information is not sent from the SSD1963 to the host
processor
0x35 set_tear_on Synchronization information is sent from the SSD1963 to the host
processor at the start of VFP
0x36 set_address_mode Set the read order from frame buffer to the display panel
0x37 set_scroll_start Defines the vertical scrolling starting point
0x38 exit_idle_mode Full color depth is used for the display panel
0x39 enter_idle_mode Reduce color depth is used on the display panel.
0x3A Reserved Reserved
0x3C write_memory_continue Transfer image information from the host processor interface to the
SSD1963 from the last written location
0x3E read_memory_continue Read image data from the SSD1963 continuing after the last
read_memory_continue or read_memory_start
Hex Code Command Description
0x44 set_tear_scanline Synchronization information is sent from the SSD1963 to the host
processor when the display panel refresh reaches the provided scanline
0x45 get_scanline Get the current scan line
0xA1 read_ddb Read the DDB from the provided location
0xA8 Reserved Reserved
ZZZWRSZD\GLVSOD\VHX