PT99 Personal Tracker User Manual
Page
Power off GSM module & GPS
module, long standby time. Only
track by clock settings
IMPORTANT: The tracker has no power switch, it is set in deep sleep mode
(111111PWR:3) in default. In the deep sleep mode, the tracker will not accept
any SMS/GPRS command.
Pressing the button shortly on the panel will wake up the device for 3
minutes, the tracker will response on the SMS command during the wake-up.
PWR:0 could be used for continuously tracking for vehicle/person, PWR:1&
PWR:2 is suggested for person tracking, PWR:3 is suggested for asset
protection with long standby time.
Settings in Deep Sleep Mode
In deep sleep mode, the device can only be woke up by the following ways:
(1). Shortly press the button, it will wake up for 3 minutes;
(2). Press the button & hold it for 3 seconds, it will trigger the SOS alarm;
(3). Only in arming status, the shock sensor can trigger the vibration alarm;
In deep sleep mode, it only reports to the platform according to the following
settings:
There might be time deviation of 2-3 minutes while tracking in this deep
mode, depending on the local network situation. When tracking by clock, please
set the clock 2-3 minutes in advance.
Track by clock:
SMS command: 111111CLK:X,C1,C2,C3,......C10, (with , at the
end).
X is the cycle time, value range: 1~10 (days)
C1,C2,C3,......C10 is the clock, maximum 10 clocks, they should be in
sequence.
E.g.: 111111CLK:1,00:15,01:38,05:20,08:10,12:30,14:55,
(Every day, it reports the location to platform according to above clocks)
111111CLK:3,18:00,
(Every 3 days, it reports the location to platform at 18:00)