Page 11 KKCIE01-A/2-20140318
5. Meter’s Reference Address
No. Register ADD Register Name Data Type Measuring Range Nature Note
0 0x0001 Value PV long ----- R Reserve 3 decimal point
1 0x0002 Batch Value BV Unsigned long ----- R
2 0x0003 Alarm Status Unsigned long -----
R
3 0x0004 OUT1 Alarm (PS1) Unsigned long 1~999999000 R/W
Reserve 3 decimal point
4 0x0005 OUT2Alarm (PS2) Unsigned long 1~999999000 R/W Reserve 3 decimal point
5 0x0006 BA.Oalarm (BA.S) Unsigned long 1~999999 R/W
6 0x0007 Scale Factor SCL Unsigned long 0.00001-9999.99 R/W
Reserve 5 decimal point
7 0x0008 Initial Value W long -99999-999999 R/W Reserve 3 decimal point
8 0x0009 Meter’s Status 1 Unsigned long ----- R/W
9 0x000A Meter’s Status 2 Unsigned long ----- R/W
10 0x000B Meter’s Status 3 Unsigned long ----- R/W
11 0x000C Meter’s Status 4 Unsigned long ----- R/W
* PV, PS1, PS2 will acquiesce in 3 decimal point. Actual data=return data or write in data/1000. If Read PV
register return data=1, the the actual PV value=0.001. At the same time, when write 10000000 into PS2 register,
then the actual OUT2setting value (PS2)=1000.0000.
6. Alarm Status (Add:0x0003)
Bit31 Bit30 Bit29 Bit28 Bit27 Bit26 Bit25 Bit24 Bit23 Bit22 Bit21 Bit20 Bit19 Bit18 Bit17 Bit16
lobmyStuptuOmralAO.ABevreseR
Bit15 Bit14 Bit13 Bit12 Bit11 Bit10 Bit9 Bit8 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
OUT2 Alarm Output Symbol OUT1 Alarm Output Symbol
6-1、Bit0-Bit7 OUT1 Alarm Output Symbol:0x00:OUT1 Alarm No Output,0x01:OUT1 Alarm and Output。
6-2、Bit8-Bit15 OUT2 Alarm Output Symbol:0x00:OUT2 Alarm No Output,0x01:OUT2 Alarm and Output。
6-3、Bit16-Bit23 BA.O Alarm Output Symbol:0x00:BA.O Alarm No Output,0x01:BA.O Alarm and Output。
7. Register of Meter Status (Add: 0x0009)
Bit31 Bit30 Bit29 Bit28 Bit27 Bit26 Bit25 Bit24 Bit23 Bit22 Bit21 Bit20 Bit19 Bit18 Bit17 Bit16
OUT2 Output delay time setting menu OUT1 Output delay time setting menu
Bit15 Bit14 Bit13 Bit12 Bit11 Bit10 Bit9 Bit8 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
OUT Output type setting value SIG Input terminal SSR choosing
7-1、Bit0-Bit7:SIG Input terminal SSR choosing(choosing range: 0x00-0x01)。
Bit0-Bit7=0x00:NPN Input mode,Meter’s signal input terminal will connect with 12V auxiliary power supply through
inner 7.4K resistance.
Bit0-Bit7=0x01:PNPinput mode, Meter’s signal input terminal will connect with public earth wire through inner5.4K resistance.
7-2、Bit8-Bit15:OUT Meter’s output mode choosing(Choosing range according to current status)。
Bit8—Bit15 Output mode
Bit8—Bit15 Output mode Bit8—Bit15 Output mode Bit8—Bit15 Output mode Bit8—Bit15 Output mode
0x00 F 0x01 N 0x02 C 0x03 R
0x04 K 0x05 P 0x06 Q 0x07 A
0x08 S 0x09 T 0x0a D
Note:Before you are changing the output mode to D , please sure that the count frequency CP≤1KHZ, otherwise it will return the error code!
7-3、Bit16—Bit31:OUT1、OUT2 Alarm Output delay time choosing menu (Choosing range 0x00-0x08).
Bit16—Bit23Corresponding OUT1output delay time Bit24—Bit31Corresponding OUT2output delay time
Bit16—Bit23 Delay time Bit16—Bit23 Delay time Bit24—Bit31 Delay time Bit24—Bit31 Delaytime
0x00 10mS 0x01 50mS 0x00 10mS 0x01 50mS
0x02 100mS 0x03 Sm00120x0Sm002 0x03 200mS
0x04 500mS 0x05 1000mS 0x04 500mS 0x05 1000mS
0x06 2000mS 0x07 Sm000260x0Sm0005 0x07 5000mS
0x08 HOLD
Note::Bit16—Bit23 choosing range(0-8)
Note :Bit24—Bit31Choosing range(0-7)
Page 12 KKCIE01-A/2-20140318
8. Register 2 of Meter Status (Add:0x000A)
Bit31 Bit30 Bit29 Bit28 Bit27 Bit26 Bit25 Bit24 Bit23 Bit22 Bit21 Bit20 Bit19 Bit18 Bit17 Bit16
oPATADesoohCedoMtupninI wer OFF data preserve choose
Bit15 Bit14 Bit13 Bit12 Bit11 Bit10 Bit9 Bit8 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
DPDecimal point display choose RSTInput control signal valid length of pulse choose
8-1、Bit0-Bit7:RST Input control signal valid length of pulse choose(Range 0x00-0x01)。
Bit0-Bit7=0x00:Input control signal valid length of pulse is 20mS。
Bit0-Bit7=0x01:Input control signal valid length of pulse is 1mS。
8-2、Bit8-Bi15:DPDecimal point display choose(Range 0x00-0x03)。
Bit8—Bit15 Decimal Point Bit8—Bit15 Decimal Point Bit8—Bit15 Decimal Point Bit8—Bit15 Decimal Point
0x00
No Decimal
Point 0x01
One Decimal
Point 0x02
Two Decimal
Point 0x03
Three Decimal
Point
8-3、Bit16-Bit23:DATA Power OFF data preserve choose(Range 0x00-0x01)
Bit16-Bit23=0x00:Count comes to Zero when Power OFF.
Bit16-Bit23=0x01:Count value will be preserved when power off and will recount from this value from next time power on!
8-4、Bit24-Bit31:INInput mode choose(Range 0x00-0x04)。
Bit24—Bit31 Input Mode Bit24—Bit31 Input Mode Bit24—Bit31 Input Mode Bit24—Bit31 Input Mode
0x00 U 0x01 D 0x02 UD-A 0x03 UD-B
0x04 UD-C
9. Register 3 of Meter Status (Add:0x000B)
Bit31 Bit30 Bit29 Bit28 Bit27 Bit26 Bit25 Bit24 Bit23 Bit22 Bit21 Bit20 Bit19 Bit18 Bit17 Bit16
CPS Count Frequency UPPer limit Choose Menu ADD Meter Communication ADD Setting Menu
Bit15 Bit14 Bit13 Bit12 Bit11 Bit10 Bit9 Bit8 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
BAUD Communication Baud Rate Setting Menu LOCK Button Level Setting Menu
9-1、Bit0-Bit7:LOCK Button Level Setting Menu(Range0x00-0x03)。
Bit8—Bit15 Level Bit8—Bit15 Level Bit8—Bit15 Level Bit8—Bit15 Level
0x00 L.OFF 0x01 LOC.1 0x02 LOC.2 0x03 LOC.3
9-2、Bit8-Bit15:BAUD Communication Baud Rate Setting Menu(Range 0x00-0x01)。
Bit8-Bit15=0x00:Baud Rate=9600Bit/S(9600)。
Bit8-Bit15=0x01:Baud Rate=4800Bit/S(4800)。
9-3、Bit16-Bit23:ADD Meter Communication ADD Setting Menu(Range 0x01-0xf7)。
9-4、Bit24-Bit31:CPS Count Frequency UPPer limit Choose Menu(range decide by output mode)。
Bit24—Bit31
Frequency
Uppper
Limit
Bit24—Bit31
Frequency
Uppper
Limit
Bit24—Bit31
Frequency
Uppper
Limit
Bit24—Bit31
Frequency
Uppper
Limit
0x00 1HZ 0x01 30HZ 0x02 1KHZ 0x03 5KHZ
0x04 10KHZ
Note: Output mode is D mode. Bit24-Bit31, choosing range (0x00—0x02), otherwise choosing range is (0x00—0x04)
10. Data Error Code
10-1. Data error code, under the condition of order format, meter address, function code and CRC check code are all correct,
when the host computer write error data into the follow computer, follow computer will return back the error code which is in
corresponding to the host computer, detail as follows:
Error Code Definition Error Code Definition
0x14 OUT1 Alarm Value(PS1)Error 0x15 OUT2 Alarm Value(PS2)Error
0x16 BA.O Alarm Value (BA.S) Error 0x17 SCL Coefficient Error
0x18 rorrEesoohCcigoLtupnIGIS91x0rorrEeulaVlaitinIW
0x1A OUT Output Mode Choose Error 0x1B OUT1 Output Delay Time Choose Error
0x1C OUT2 Output Delay Time Choose Error 0x1D RST Min Reset time Choose Error
0x1E DP Decimal Point Choose Error 0x1F DATA Reserve Count Value Choose Error
0x20 IN Input Mode Choose Error 0x21 LOCK Button Choose Error
0x22 BAUD Communication Baud Rate Choose
Error 0x23 ADD Meter Communication Address Setting
Error
0x24 CPS Max. Count Speed Choose Error 0x25
0x26 0x27
Announcement:
When write the data into the meter through communication port, the write-in time of each storage element is
limited, CI series counter meter
than the provide, it can cause the damage on meter’s storage element!
can accept at least 100 thousand times write-in. If write-in time exceed