TIS TIS258 Manuel utilisateur

Instruction Manual Version 2.00
0
TIS258
Digital Multimeter

1
CONTENTS:
1.0 Introduction ------------------------------------------------------------------------------------------------------------ 2
2.0 Accessories -------------------------------------------------------------------------------------------------------------3
3.0 Safety Instructions ----------------------------------------------------------------------------------------------------3
3.1 Safety Symbols----------------------------------------------------------------------------------------------------4
3.2 Warranty-------------------------------------------------------------------------------------------------------------5
4.0 Instrument Layout, display information & symbols-------------------------------------------------------------6
5.0 Description of Measurement Operation --------------------------------------------------------------------------7
5.1 AC/ DC Voltage Measurement -------------------------------------------------------------------------------------7
5.2 AC/DC Current Measurement --------------------------------------------------------------------------------------8
5.3 Diode Measurement --------------------------------------------------------------------------------------------------8
5.4 Continuity Indication / Buzzer Test --------------------------------------------------------------------------------8
5.5 Resistance Measurement --------------------------------------------------------------------------------------------9
5.6 Temperature Measurement ------------------------------------------------------------------------------------------9
6.0 Technical Specifications ----------------------------------------------------------------------------------------------10-15
7.0 Installation / Replacement of Battery & Fuse Protection -----------------------------------------------------16

2
1.0-Introduction
Thank you for purchasing the TIS258
The TISS258 Digital Multimeter, is a 31/2-digit multimeter with the following capabilities / functionality:
Function
Range
Function
Max. Display
2000 counts
Diode
Yes
Basic Accuracy
0.5%
Continuity
Yes
DC Voltage
200mV-500V
Data Hold
Yes
AC Voltage
200mV-500V
Back Light
Yes
DC Current
200µA-10A
Auto Power off
Yes
AC Current
200µA-10A
Manual Range
Yes
Resistance
200-20M
Battery
9V x 1
Temperature
-20℃-750℃
Diode
Yes
-4℉-1382℉
Continuity
Yes

3
2.0 –Accessories
Test lead(s) (Red + Black) ----------------------------------------------------------------------------2
9V PP3 alkaline battery---------------------------------------------------------------------------- 1
User Manual ------------------------------------------------------------------------------------------ 1
3.0- SAFETY INSTRUCTIONS
Warning –Please read and follow the following:
Before using the instrument, test leads and / or the adaptors please ensure there are no signs of damage
as this could result in electrical shock and / or inaccurate results.
Once the battery indicator appears, please replace the battery. As low battery level can produce
inaccurate results.
Do not use / store the instrument in high temperature, humid, flammable, or electromagnetic
environments as this could result in injury, damage to the instrument and / or inaccurate results.
If the instrument / equipment is use in a manner not specified by the manufacturer, the protection
provided by the instrument may be impaired.
Do not connect test leads to live systems or hazardous voltages unless stated within the manual.

4
3.1 Safety Symbols
Warning & caution safety label
Double insulation
DC (Direct Current)
AC (Alternating Current)
Low battery
Dangerous high voltage!
Buzzing on-off
Earthing
Comply with EC standard
Applicable to test and measuring circuits connected at the
source of the building's low-voltage MAINS installation.
CAT IV

5
3.2 - Warranty
NEW INSTRUMENTS HAVE A WARRANTY PERIOD OF: 1 YEAR FROM THE DATE OF PURCHASE
BY THE USER.
(A copy of the original purchase invoice may be requested to validate the purchase date).
This warranty period includes parts and labor only.
Any unauthorized repair / adjustment will void the warranty.
For service / calibration / repair requirements, please contact:
TEST INSTRUMENT SOLUTIONS LIMITED
UNIT 12/14, LUDDITE WAY BUSINESS PARK
RAWFOLDS WAY
CLECKHEATON
BD19 5DQ
Tel: 01274 752407
Email: SALES@TIS-TIC.CO.UK

6
4.0 Instrument Layout, display information & symbols
1. LCD display
2. Select Button (Switch the measurements of AC,
DC current; Temperature, Diode & Continuity check)
3. MAX Hold button
4. Rotary/ Function Selector Switch
5. 10A, Input Terminal
6. LED Indicator
7. Backlight Button
8. Data Hold Button
9. COM, Input Terminal
10. V,Ω,mA, Input Terminal

7
5.0 - Description of Measurement Operation
AC / DC Voltage Measurement
1) Set the rotary switch to the voltage position. (V / V~)
2) If required press the select button to change the voltage sine wave from DC V to AC (V~)
3) Insert the black test lead banana plug into the negative COM input terminal & insert the red
test lead banana plug into the positive V/ΩmA input terminal.
4) Connect test leads to the conductors to be tested.
5) Read the voltage in the LCD display.
PLEASE NOTE: That the polarity of red test lead must be connected to the positive conductor
to indicate the positive voltage measurement when conducting DC voltage measurements.

8
AC/DC Current Measurement
1) Select the rotary switch to the appropriate current measurement function & range.
2) Insert black test lead banana plug into the negative COM input terminal.
3) To perform current measurements less than 200mA insert the red test lead banana plug into
the mA Input terminal or for current measurement between 200mA to 10A insert the red test
lead banana plug into 10A input terminal
4) Disconnect the circuit under test then connect the test leads in series with the circuit.
5) Turn the power on and read the measurement value displayed.
If OL (Over Limit) is displayed, increase the measurement range / function.
Diode Test
1. Set the rotary switch to the “ ” position.
2. Connect the black test lead to the "COM" terminal and the red test lead to the "VΩ:" input terminal.
3. Pres the “SEL” button to select the diode function (If required)
4. Connect the test leads to the diode, test both the “Forward Bias & Reverse Bias” of the diode under test.
Open circuit measurements will be indicated as OL on the display,
Continuity Indication / Buzzer Test
1. Set the rotary switch to the “ ” position.
2. Connect the black test lead to the "COM" terminal and the red test lead to the "VΩ:" input terminal.
3. Pres the “SEL” button to select the continuity function (If required)
4. Connect test leads to the circuit under test.
5. Measurement will be displayed and the audible indicator will sound, when measurements are under 70Ω.

9
Resistance Measurement
1. Set the rotary switch to the required resistance range.
2. Insert the black test lead banana plug into the negative COM input terminal & insert the red
test lead banana plug into the positive V/ΩmA input terminal.
3. Connect test leads / probes to the measuring points
4. Read resistance measurement displayed on the LCD.
If OL (Over Limit) is displayed, increase the measurement range / function.
Temperature Measurement
1. Set rotary switch to the “°C°F” function.
2. Select the measurement type by press the “SEL” button.
3. Connect the thermocouple by inserting the black lead in to the COM input terminal & insert
the red lead in to the V/ΩmA input terminal.
4. Place the thermocouple either on or in the vicinity of the object / room under test.
5. Wait while measurement stabilizes.
6. Read temperature measurement displayed on the LCD.
Table des matières
Autres manuels TIS Multimètre
Manuels Multimètre populaires d'autres marques

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 Manuel utilisateur

PeakTech
PeakTech 4000 Manuel d'utilisation et d'entretien

YOKOGAWA
YOKOGAWA 90050B Manuel utilisateur

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 Manuel utilisateur

Fluke
Fluke 8846A Manuel d'utilisation et d'entretien

Tempo Communications
Tempo Communications MM200 Manuel utilisateur