Thermo Solar SGC16 Manuel utilisateur

SGC16
Differential controller
SGC16: 1 output, 2 inputs
ENG
SVK
Differenzregler
SGC16: 1 Ausgang, 2 Eingänge
Diferenčný regulátor
SGC16: 1 výstup, 2 vstupy
DEU
A1360
8/2013

A1360
8/2013

ENGDEUSVK
Differential controllers
SGC16
Differenzregler
SGC16
Diferenčný regulátor
SGC16
A1360
8/2013

4
ENG
INTRODUCTION
Differential controllers SGC16 are modern designed, microprocessor-driven devices made
with digital and SMT technology.
These devices are intended for regulating domestic hot water warming by means of solar
collectors or for regulating domestic hot water warming by means solid fuel boiler, electric
heater or other energy resources.
Differential controllers SGC16
For initial setup see Initial controller setup, page 7!
A1360
8/2013

ENG
5
CONTENTS
USER MANUAL
Appearance of controller SGC16................................................................................ 6
Initial controller setup.................................................................................................. 7
Graphic LCD display ................................................................................................. 9
Description of symbols shown on the display ......................................................... 10
Display for help, notices and warnings...................................................................... 12
Menu entry and navigation ...................................................................................... 13
Menu structure and description................................................................................ 14
Temperature settings............................................................................................... 17
User functions ......................................................................................................... 18
Operation mode selection........................................................................................ 19
Time program settings ............................................................................................ 20
Basic settings........................................................................................................... 23
Data overview ......................................................................................................... 25
SERVICE MANUAL
Controller parameters and auxiliary tools................................................................. 26
Basic parameters................................................................................................. 26
Service parameters ............................................................................................. 28
Heat metering parameters .................................................................................. 32
Heat metering ....................................................................................................... 33
Factory settings ...................................................................................................... 34
Controller data ........................................................................................................ 34
INSTALLATION MANUAL
Controller installation .............................................................................................. 35
Wall installation........................................................................................................ 35
Marking and description of temperature sensors .................................................... 36
Controller’s electric connection ................................................................................. 37
Flow meter installation ............................................................................................ 38
Connection of a high-efficiency pump with an external control signal....................... 38
Setting the flow in a solar system and testing the control function............................ 39
Temperature simulation mode .................................................................................. 39
Technical data .......................................................................................................... 40
Declaration of conformity .......................................................................................... 41
Disposal of old electrical and electronic equipment .................................................. 41
Guarantee................................................................................................................. 42
Hydraulic and electric schemes .............................................................................. 121
Installation record ................................................................................................... 125
A1360
8/2013

6
User and settings manual
ENG
USER MANUAL
APPERANCE OF CONTROLLER SGC16
Graphic display
Button
(Esc - return back)
Button (Help)
Button
(move to left, decreasing)
Screw for fastening the cover
Button
(menu entry, confirmation of selection)
2
1
3
5
4
6
7
8
Button
(move to right, increasing)
Cover for connection area
1
2
3
4
5
6
8
7
A1360
8/2013

7 User and settings manual
ENG
INITIAL CONTROLLER SETUP
SGC16 differential controllers are equipped with an innovative solution, which allows
initial setup of the controller in only two steps.
When you connect the controller to the power supply for the first time, the software ver-
sion is shown. Next, the first step appears on the screen.
Using buttons and you select the required language.
Press the button to confirm the selected language.
After selecting the language, the controller requires
confirmation of the selection by pressing the
button.
If you accidentally selected the wrong language, go
back to reset the language by pressing button .
If you cannot find the required language on the first screen, move to the fol-
lowing screens by pressing the button .
STEP 1
A1360
8/2013

8
User and settings manual
ENG
Selected hydraulic scheme can be later changed with service parameter S1.1.
Controller RESET!
Disconnect the controller from the power supply. Press and hold the button
and switch on power supply. The controller resets and goes to initial set-
up.
CAUTION!
By selecting ‘reset’ all previous controller settings are erased.
Next, you select a hydraulic scheme for the controller
function. Move between schemes by means of buttons
and .
Confirm the selected scheme by pressing the button.
STEP 2
After you selected the scheme, the controller requires
confirmation of the selection by pressing the button.
If you accidentally selected the wrong scheme, go back
to reset the scheme by pressing button .
A1360
8/2013

9 User and settings manual
ENG
Controller mode
Active time program
Active functions
Measured
temperatures,
state of output
and other data
Time
and
date
All important data of controller operation are shown on the graphic LCD display.
Advanced review of temperatures:
Measured temperature
Set point temperature
DESCRIPTION AND DESIGN OF THE MAIN DISPLAY:
For temperature and other data review we use buttons and .
Number of sensors and other data seen on the display depends on the selected hydraulic
scheme and controller settings.
2s
Which data are shown on the basic display depends on the selected scheme.
If we want to change the displayed information, press button or
to select the required data and confirm it by holding button for 2 se-
conds.
Warnings
State
of output
Diagram
of hydraulic
scheme
Measured
temperatures
Sensors, that aren’t required for the selected scheme and aren’t connected,
are indicated with symbol .
GRAPHIC LCD DISPLAY
A1360
8/2013

10
User and settings manual
ENG
All important data about controller operation are seen on the LCD display.
We browse through data by means of buttons and . .
OPERATION MODE SYMBOLS
Symbol Description
Controller operates in automatic mode
Controller operates automatically according to program timer ,
, or . ON and OFF indicates status of the timer.
Manual operation mode
Controller is in Stand-by.
One-time warming of domestic hot water function is activated
Holiday mode function is activated
Return cooling of storage tank is activated
Protection against overheating of the solar collectors is activated
Protection against freezing of the solar collectors is activated
Protection against legionella is activated
State of output ON
OFF
RPM stage indication for pump R2
Indication impulsive pump mode - tube collectors (Parameter S2.2)
Inverted operation of output
DESCRIPTION OF SYMBOLS SHOWN ON THE DISPLAY
A1360
8/2013
Table des matières
Langues :
Autres manuels Thermo Solar Contrôleurs