2. Connect a ½” NPT brass pipe or tubing to the steam outlet on the generator run the pipe to
the 2.5” hole in wall to connect with the steam head housing, use figure 5 as a guide. It is
very important that the pipe is firmly secured to the wall, so that when the steam head
is installed it doesn’t push the housing back into the wall. The steam line can run up,
down, or horizontal; but cannot run down and then up. If it does, a steam trap may be
produced at the low point blocking the flow of steam. Install a ½” drop elbow on the end of the
½” pipe or tubing for the steam head housing. For all the connections, use Teflon tape/solder
and do not over tighten fittings. DO NOT USE PVC CEMENT.
3. Final Installation (steam head): When installing the steam head in to the housing be sure that
the aromatherapy fill channels are facing upwards see figure 6. To ensure that no moisture
gets behind the steam head and into the wall, place a generous bead of waterproof silicone
around the steam head, use the machined grove as a guide. Be sure that within the housing
there isn’t any debris, and the two O-rings are in place on the steam head. Slide the steam
head into the housing until the steam head is tight against the finished wall. You may need to
wipe away any excess silicone. Use figure 6 as a reference to these steps.
DOC NO. 81060 10 OF 18 RevA 06/01/03
`
WARNING: Avoid contact with steam head! It will burn you! Avoid direct contact with
the steam coming out of the steam head! It is extreamly hot and will burn you! Never put
Aroma oil in the steam head when the unit is in the on position, or when steam is emitting
from the steam head.
This edge must be flush
with finished wall (+/- 1/8”)
Place silicone
around this
groove
Aromatherapy
Fill Channels
Figure 6
O-Rings