INS20190711-02
Read carefully these instructions before installation, operation
of the heater. Failure to adhere to the instructions could result in
re, electric shock, serious personal injury, and death or property
damage. Review frequently for continuing safe operation and
instruction of future users, if necessary.
IMPORTANT
INSTRUCTIONS
1- Read all instructions before installing or using this heater.
2- This heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces. Keep combustible materials, like
furniture, pillows, bedding, papers, electrical cords, clothes,
and curtains at least 36 in. (915 mm) from the front of the
heater and away from the sides.
3- Extreme caution is necessary when any heater is used by
or near children or invalids and whenever the heater is left
operating and unattended.
4- Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a reputable
electrician before reusing.
5- Do not use outdoors.
6- To disconnect heater, turn o the circuit breaker that is
connected to the heater, then disconnect it from the thermostat/
control at the wall.
7- Do not insert any foreign objects in the heater as this may cause
an electric shock or re, or damage the heater.
8- Certain components may produce arcing or sparking. Do not
use it in areas where gasoline, paint, or ammable vapors or
liquids are used or stored.
WARNING
When using electrical appliances, basic precautions should
always be taken to reduce the risk of re, electrical shock and
injury, including the following.
9- Use this heater only as described in this manual. Any other use
not recommended by the manufacturer may cause re, electric
shock, or injury to persons.
10- The thermostat should not be considered an infallible device in
cases where maintaining a temperature is considered critical.
Examples: Hazardous material storage, computer server
room, etc. In these particular cases, it is imperative to add a
monitoring system to avoid the consequences of a thermostat
failure.
11- Never paint the front panel of the heater.
12- Heater should not be blocked in any manner.
13- For ceiling installation only.
14- Check voltage rating of heater to make sure it is same as
supply voltage.
15- Do not install the heater directly over a shower cubicle,
nor in places where it will be exposed for a long period
to high humidity or moisture.
16- This heater is hot when in use. To avoid burns, do not install
this heater in an accessible place. Allow 8 ft. (2.4 m)
minimum clearance from the oor.
17- A badly installed heater can be permanently damaged and
present a risk of re or electric shock. The heater must be
rmly xed to the ceiling structure.
SAVE THESE
INSTRUCTIONS
MAINTENANCE
INSTRUCTIONS
1- Cleaning should be done while the heater is disconnected
from the main service panel. Wait until the housing
and heating element cool before performing maintenance.
2- To clean the painted surface, use a cloth moistened with a
mixture of water and vinegar in equal proportions.
3- A detergent can be used to remove residue due to its
environment (warehouse, industrial premises, etc.), but it is
strongly recommended to test a small section in area that
is not visible.
4- Do not use abrasives or corrosive chemicals as this may damage
the paint and the appearance of the product.
5- The front panel of the panel can not be repainted.
6- The back of the panel can be repainted with latex paint.
7- Any other servicing should be performed by a qualied
technician.
WARRANTY
Please refer to the product sheet at www.ouellet.com.
OPERATING
INSTRUCTIONS
1- The heater must be properly installed before it is used.
2- Turn the power on at the circuit breaker panel.
3- The use of the heater may vary depending on the type of
control used. Please refer to the operation manual of the
thermostat, timer or switch.
670 Wilsey Road, Unit 6
Fredericton, New Brunswick, Canada, E3B 7K4
Tel.: 1 866 457-4600
www.thermaray.com
INSTRUCTIONS
Architectural Radiant Panel
AS Models
Conforms to UL STD 2021
Certied to CSA STD C22.2 No.46