Basic technical parametres:
Power supply 9 to 15V ss, 500mA
GSM network 900/1800MHz
dimension: 145 x 75 x 30 mm
Features :
oPower supply from distribution net 12V or alternative from
main power supply (12V adapter). Also can be used
backup battery 12V with charging adapter.
o2 inputs for switching contacts (alarm output, sensors etc.)
(5V)
owhen is short circuit at input preprogrammed SMS is sent
to preprogrammed number (for each input own text SMS
as same as number)
owhen is short circuit at input progressive ringing up 8
preprogrammed numbers (ALARM1 to ALARM8)
o2 galvanically separated (switching contacts 230V/ 5A)
o2 switching contacts control by ringing only from authorised
numbers (contact closed for preprogrammed fix time )
oThe size of authorised numbers is limited by SIM card
capacity (250). The numbers can be saved under different
names
oBoth outputs control by SMS from numbers authorised in
II. level (ALARM). It is possible remotely control closing,
disconnection, closing for 1-99 minutes
oSetting of all parametres (authorised numbers, unit time,
competence etc.) a s same as complete control of the unit
(for example: remote dialling different number from
preprogrammed) by SMS from authorised numbers in level
III. (ADMIN)
oCkecking of credit level. Sending of SMS coming from
operator to preprogrammed number.
oSetting of all parametres via PC through RS 232 port. All
parametres can be programmed directly on SIM by mobile
phone or remotely by SMS
oSystém interface for optional devices

2
Installation
The unit may be installed on DIN ribbon, screw on the wall or
put to the shelf. The unit is not designed for installation in high
humidity environment. If you want install it in external
environment you have to fix it into waterproof box.
SIM card setting
Insert SIM card to various mobile phone
Where you can programm neccessary parametres.
Much more comfortable way is insert it into unit and
parametres programm via PC through attached programming
cable. For PC setting use configuration software on CD which
is attached to the unit.
CAUTION! On the SIM card must be saved at least 1 phone
number when you want control relay by ringing. Further
more at least 1 ADMIN phone number, when you want
remote control of the unit. At least ALARM1 phone
number, when you want receive call after input activation.
THE NUMBERS MUST BE IN INTERNATIONAL FORMAT!
Inserting of SIM card into unit
Pull out SIM card holder by pressing of yellow button on right
side of the unit. The SIM card put to holder and replace it.

3
Schematics of feeding with delivered power supply
Schematics of feeding with charging
power supply and backup 12V ACU

4
Schematics of feeding from 12V distribution
Schematics of Inputs/Outputs
12V distr, consumption
max
500mA
Input 1
(against GND)
Input 2
(against GND)
Output A Output B
GND

5
Inputs connection examples:
Connection with relay
contacts, switches,
magnetic contact switchers
etc.
Connection of galvanically
isolated switch with
optotransistor
Outputs connection examples:
High power relay (clamper)
connection , lightbulb
connection (heating, engine
etc.).
Selftest Input 1 (due relay A) –
possibility activate Alarm
remotely, Blocking Input 2 (due
relay B) – Remote control of
alarm circuit = Guarding for
limited time

6
Indication LED
Blue LED
Lighting – feeding from power supply
Flashing – feeding from Backup ACU
Yellow LED
Short flashing – GSM network search
Slow flashing – GSM network ready
Fast flashing – SIM card error
Red LED
Lighting during input
activation
Green LED
Flashing – output permanently closed
Lighting – output closed for mm minutes

7
Names and numbers to save on SIM card
Name functionality
various By ringing activate output A (closing time set in RTIME)
ALARM1
to
ALARM8
- By ringing activate output A (closing time set in RTIME)
- By SMS activate output A and B
- By SMS control (status, version, IMEI, credit)
- During failure on input 1(2) is send SMS from position 2(3)
and progressively ring to line of ALARMx numbers (until line
interruption)
- when power supply is disconnected for 30 sec. and more
the SMS in format 'ACCU,credit’ is sent to ALARM8 number
- when power supply is working again longer than 30 sec. the
SMS in format 'POWER ON,credit' is sent to ALARM8
number
ADMIN1
to
ADMIN8
- By ringing activate output A (closing time set in RTIME)
- By SMS activate output A and B
- By SMS control (status, version, IMEI, credit)
- By SMS edit numbers and names saved on SIM card
- By SMS control further functions (AT commands)
ARMSMS1
to
ARMSMS8
Extendig of phone numbers where are send SMS messages
from Input 1 and 2. When ARMSMS is used and SMS are
not preprogrammed, the sends SMS „INPUT1 (2)“.
ARMSMSs phone numbers „MUS NOT“ be the same as
ALARMs or ADMINs numbers !!!
CRED - code to assure credit level
(*101# ... for T-MOBILE, *104*# ... for O2)
OPER - GSM operator number where from coming inform SMS
(expiration time etc..). The SMS is resent to ALARM8
RTIME - Time of closing output A after ringing (1-99sec), default
3sec
The name and numbers may be saved to SIM card phone
book by mobile phone or by PC via configuration sw. The
names ALARMx, ADMINx, ARMSMSx, CRED, OPER and
RTIME must be written by BIG characters. Between name
ALARM (ADMIN, ARMSMS) and number ( ALARM1,2…)
must not be a space. The ALARM numbers must have
voice mail switch OFF! When ALARM number is busy or
unreachable the call is picked up by voice mail and further
numbers are not ringed!

8
Command SMS – SMS with other content are refused
Command ( SMS) Function response
ADMINx,+420cc...c Save or rewrite ADMINx
number 'OK,credit'
ADMINx, Erase ADMINx number 'OK,credit'
ALARMx,+420cc...c
Save or rewrite ALARMx
number 'OK,credit'
ALARMx, Erase ALARMx number 'OK,credit'
ARMSMSx,+420c.c Save or rewrite ARMSMSx
number 'OK,credit'
ARMSMSx, Erase ARMSMSx number 'OK,credit'
CRED,x..xx Save or rewrite CRED number 'OK,credit'
CRED, Erase CRED number 'OK,credit'
OPER,x..xx Save or rewrite OPER number 'OK,credit'
OPER, Erase OPER number 'OK,credit'
RTIME,ss Time closing of output A during
ringing (ss=01..99 sec) 'OK,credit'
SMSx,x..x,text Save SMS on position x (1-6) 'OK,credit'
SMSx, Erase SMS on position x 'OK,credit'
NAME,+420cc....c Save phone number for NAME 'OK,credit'
NAME, Erase all numbers with NAME 'OK,credit'
NAME,+420cc....c-
DEL Erase exact number with NAME
(may exist more times !) 'OK,credit'
CAL,AT+CSQ Valuation of GSM signal
strenght '+CSQ,17,99,
credit'(max 32)
SMS is possible send from ADMIN numbers only!
CAL,AT+CPBR=x Detection of number saved on
position x '+CPBR:1,”+42
1012345678”,
145,”ADMIN1”
STAT Status inquiry 'status,verze,i
mei,credit' )*
REL1,ON Activate relay 1 (Output A) 'OK(REL1,ON)
,credit'
REL1,OF Deactivate relay 2 (Output A) 'OK(REL1,OF),
credit'
REL1,ON,mm Activate relay 1 (Output A) for
time mm, where mm=01..99
min
'OK(REL1,ON,
mm),credit'
REL2,ON Activate relay 2 (Output B) 'OK(REL1,ON)
,credit'
Valid for ALARM numbers
REL2,OF Deactivate relay 2 (Output B) 'OK(REL1,OF),
credit'

9
REL2,ON,mm Activate relay 2 (Output B) for
time mm (mm=01..99 min) 'OK(REL1,ON,
mm),credit'
Note:
credit The level of remaining credit on prepaid cards.
x..xx telephone number
text text of SMS message
SMS1 SMS message sent when unit is switch ON
SMS2 SMS message sent during activation input 1
SMS3 SMS message sent during activation input 2
SMS4-6 back up for OEM messages
)* status – Inputs as same as outputs status in order
INPUT1, INPUT2, RELAY1, RELAY2.
INPUTx = 1 – stand by
0 – alarm status
RELAYx = 0 – switch off
1 – switch on permanently
2 – switch on for time 'mm'
verze – firmware version
imei – IMEI of integrated GSM modul
CAL, after command CAL you can put various AT command
of used GSM modul (for example: modul reset , time
setting etc...) . The commands should be used by
authorised person only! It may cause demage of
all unit!
Closing contacts by ringing
The relay outputs might be closed on 2 sec (or time RTIME) by
ringing from various number saved on SIM card (Even ALARM
and ADMIN). The output A is closed by direct ringing, Output B
by „diverted ringing“. To create „diverted ringing“ we have to
get next telephone number (called „X“) , on which we activate
permanent divert to number used in GSM Key. To close output
B we do not call number in GSM Key but number „X“ – follow
is managed by GSM Key and GSM operator.
Manuels Télécommande populaires d'autres marques

Panasonic
Panasonic EUR7622KB0 Manuel utilisateur

Bang & Olufsen
Bang & Olufsen Beo4 Manuel utilisateur

Sunwave Tech.
Sunwave Tech. RemoteComm SRC-7000 Manuel utilisateur

Multiplex
Multiplex PROFI TX 9 Manuel utilisateur

One Remote
One Remote RMB4 Manuel utilisateur

FUTABA
FUTABA 9ZAP - PART2 Manuel utilisateur