tell PAGER7 Manuel utilisateur

FOR MODULE VERSION V1.0 AND NEWER

1
Dear customer!
Thank you for choosing our product. This manual contains important information about installing
and remote controlling the Pager 7 module.
Please read this document carefully before using the product!
The latest version of Pager 7’s remoter software and user manual are
downloadable from the manufacturer’s website:
http://tell.hu/en/products/gprs-communicators/pager-7
Main features:
●3G communication
●6/4 configurable NO/NC zone inputs
●1/2 NO relay output: remote controllable by event
●Configurable event-action pairs
●Configurable active dashboard with active tiles at will
●Configurable Contact IDs for every input and custom event
●E-mail sending, SMS sending and voice call functionality
●Multiplatform application (Windows, Linux, MacOS)
●Cameras can be assigned with zones to display and record their images in case of an
alarm
●Independent alarm function
●Support of TELLMon / SIA IP protocol
Application area:
●Mini alarm system
●Provide surveillance functions with security cameras
●Connection alarm systems with monitoring stations
●Using in building engineering (control based on sensor information)
●Agricultural use (control based on sensor information)

2
Table of contents
1. System operation and technical details 4
1.1 The module’s short description 4
1.2 Automatic power disconnection function 4
1.3 Data traffic 4
1.4 Processing of personal data 5
1.5 Technical specification 6
1.6 Contents of the package 6
2. Mounting the module and putting into operation 7
2.1 Module version 7
2.2 Inputs and outputs 7
2.2.1 Connecting inputs 7
2.2.2 Connecting temperature sensor 7
2.2.3 Connecting outputs 7
2.3 Powering the module 8
2.4 Wiring 8
2.4.1 Wiring of Pager 7 Z4 8
2.4.2 Wiring of Pager 7 Z6 9
2.5 SIM card related information 9
2.5.1 Selecting services 9
2.5.2 SIM card holder 10
2.6 Connecting the antenna 10
2.7 Installation environment 10
2.8 Putting into operation 11
2.9 LED signals 11
3. The Pager 7 programming software 11
3.1 User levels 11
3.2 Logging into the programming software through USB connection 12
3.3 Logging into the programming software through internet connection 12
4. Programming the Pager 7 module 13
4.1 The module 13
4.1.1 Module settings 14
4.1.2 Module status 16

3
4.2 Zone settings 17
4.3 Cameras 20
4.3.1 Camera settings 20
4.3.1.1 ONVIF camera link extraction 21
4.3.2 View cameras 21
4.3.3 Playing records menu point 22
4.4 Configuring active dashboard 22
4.4.1 Adding widgets 22
4.5 Notification settings 24
4.5.1 Phone numbers menu point 24
4.5.2 Text templates menu point 25
4.5.3 Emails menu point 25
4.5.4 Sounds menu point 25
4.5.5 Push notifications 26
4.6 Alarm settings menu point 26
4.7 Signalling to monitoring station 26
4.7.1 Surveillance settings menu point 27
4.7.2 Surveillance schemas 28
4.8 Event settings 29
4.8.1 Events 30
4.8.2 Actions 33
4.8.3 Presets 35
4.9 Log, configuration and debug 36
4.9.1 Log menu point 36
4.9.2 Configuration menu point 37
4.9.3 Debug information 37
5. Alternative programming options 38
5.1 DTMF commands 38
5.2 SMS commands 39

4
1. System operation and technical details
1.1 The module’s short description
The Pager 7 is a versatile 3G-based communicator module, that can be used to perform small
automation tasks, surveillance tasks (with camera management) and it can also be used as a
stand-alone security system. The product’s speciality is the multiplatform application for
programming the Pager 7 device remotely through the internet or via USB.
1.2 Automatic power disconnection function
The Pager 7 is provided with built-in automatic power disconnection function. If the supply
voltage drops below 8.3V, the module turns off automatically and it turns back on when the
supply voltage is at least 11.6V.
Attention! The minimum supply voltage level required to turn the module on is 11.6V!
After turned on with supply voltage higher than 11.6V, the module can operate stably
even at lower supply voltage, but not lower than 8.3V.
If the module is powered from a power supply provided with a backup battery and there is no
other electrical load on the battery when charging fails (e.g. in case of a power cut), while the
battery discharges, the module turns off automatically at 8.3V voltage level.
Thereafter, if the battery is in good condition, it can regenerate and can reach the terminal
voltage of 11.6V where the module turns back on, then the battery may discharge again below
8.3V. This may result a continuous switching on and off cycle that lasts until the battery can no
longer regenerate to the 11.6V voltage level. If this phenomenon occurs, the battery is flat and it
should be replaced.
1.3 Data traffic
The estimated traffic on the SIM card inserted into the Pager 7 module is expected to be
approximate ~20 MB per month by minimum usage. The data traffic rate depends on the
frequency of use, the stability of the cellular network and the services used.
Data traffic generating services:
●Remote programming/controlling
●Reporting to a monitoring station
●Downloading event log and configuration remotely
●Firmware upgrade
●Notification sending (e-mail, voice call, SMS)
●Report sending

5
The rate of data traffic depends on the usage frequency and duration of the services listed
above.
Attention! The actual data traffic can be the multiple of the minimum usage depending on
the used services!
1.4 Processing of personal data
For using some of the features the users need to specify certain personal information, just like
their notification email address and phone number, SIM card’s PIN code and the location details
of the device. This personal data is only required if you want to use features like e-mail
notification sending.
Users’ consent to processing their personal data shall be deemed to be given on the basis of
their clear and explicit consent by providing voluntarily the personal data in a direct or indirect
way. The purpose of personal data processing is to ensure access to the system and thus to
provide permission of use for users who wish to use the system. The system stores the
personal data in the device’s memory.
The personal data are not accessible for third party, only for the system operator/installer and
the assigned system administrators. The assigned system administrators are obliged to treat the
personal data confidentially, in line with the legislative provisions, and shall not disclose the data
to third party.
The Manufacturer takes any kind of responsibility for and in connection with the functionality and
use of the system –including proper use of hardware and software –according to the relevant
provisions of law.

6
1.5 Technical specification
Supply voltage:
9-30 V DC
Nominal current consumption:
120mA
Maximum current consumption:
500mA @12V DC; 250mA @24V DC
Maximum relay output load:
1A @ 24V AC/DC
GSM phone type:
QUECTEL UG95
GSM band:
900/1800MHz
UMTS band:
900/2100MHz
Dimensions:
84x72x32 mm
Weight:
200 g
Operation temperature:
-20°C; +70°C
1.6 Contents of the package
●Pager 7 + terminal connector
●GSM 900/1800MHz antenna
●User manual
●Warranty card

7
2. Mounting the module and putting into operation
2.1 Module version
The Pager 7 has two module version. The first has 4 contact inputs (IN1...IN4) and 2 relay
outputs (OUT1, OUT2) –Pager 7 Z4, while the second one has 6 inputs (IN1...IN6) and 1 output
(OUT1) –Pager 7 Z6.
For connecting the module correctly, wiring diagrams of the corresponding version must be
used!
2.2 Inputs and outputs
Attention! Do NOT connect the module’s terminals directly or indirectly to the protective
ground, because this may damage the module!
2.2.1 Connecting inputs
Both the inputs of Pager 7 and the event-actions for their activation can be customized, so the
NO or NC wiring can be also used in accordance with the selected usage.
The normally closed and normally open contacts are considered between the selected input
(eg.: IN1) and the negative „V”-terminal of the supply voltage and need to be connected
accordingly.
For the proper operation of inputs, it is essential to specify the type of inputs (NO or NC) and
enable them in the programming software. These settings are explained in detail in section 4.2
of this manual.
2.2.2 Connecting temperature sensor
Each input of Pager 7 is capable of handling temperature sensor (easyTemp). Connect the
signal output of the temperature sensor to the selected input of the module and set the input
type to temperature sensor in the programming software. This setting is explained in detail in
section 4.2 of this manual.
2.2.3 Connecting outputs
The outputs of Pager 7 are normally opened (NO) so wire them accordingly to process the given
task. The normally open (N.O.) output provides open contact by default and closed contact upon
control. The maximum relay output load is 1A at 24V AC/DC voltage.

8
2.3 Powering the module
For powering Pager 7 module 9-30V DC is required. The module’s nominal current consumption
is 120mA, however, it may occasionally increase to several times (up to 500mA at 12V DC).
The incorrect power supply may cause the module to malfunction!
If the proper power supply cannot be assured otherwise, auxiliary power supply (230V AC/12V
DC; 1A) can be ordered from the manufacturer.
2.4 Wiring
2.4.1 Wiring of Pager 7 Z4
System terminal inputs and outputs:
V+: Supply voltage 9-30V DC (min. 500 mA)
V-: Supply voltage negative polarity
IN1: 1. contact input
IN2: 2. contact input
IN3: 3. contact input
IN4: 4. contact input
OUT1: 1. normally open relay contact
OUT2: 2. normally open relay contact
In our example IN1 and IN2 inputs are normally
open (NO), while IN3 and IN4 are normally closed
(NC) inputs.

9
2.4.2 Wiring of Pager 7 Z6
System terminal inputs and outputs:
V+: Supply voltage 9-30V DC (min. 500 mA)
V-: Supply voltage negative polarity
IN1: 1. contact input
IN2: 2. contact input
IN3: 3. contact input
IN4: 4. contact input
IN5: 5. contact input
IN6: 6. contact input
OUT1: 1. normally open relay contact
In our example IN1, IN2 and IN3 inputs are normally open
(NO), IN4 and IN5 inputs are normally closed (NC), while
IN6 input is a temperature sensor (easyTemp).
2.5 SIM card related information
2.5.1 Selecting services
To select which services to activate on the SIM card, you need to know what features of Pager
7 you’d like to use in practice.
Several features of Pager 7 require having a mobile internet connection. A few of these features
are remote programming, remote firmware update, reporting to a monitoring station and certain
notification options like e-mail sending. In case the SIM card has no mobile internet service the
module can be programmed only through USB connection and it can send only SMS or call
notification.
To use the internet service, you need to enter the SIM card’s Access Point Name (APN) in the
programming software. You can obtain the SIM card’s public APN from your GSM provider.
APN settings are explained in detail in section 4.1.1 of this manual.
The functions that use SMS sending need SMS service and the ones that use calls require
GSM voice call service.
Table des matières
Autres manuels tell Système de sécurité
Manuels Système de sécurité populaires d'autres marques

EDM
EDM Solution 6+6 Wireless-AE Manuel utilisateur

Highway Safety Group
Highway Safety Group EA401 Manuel utilisateur

Siren
Siren LED GSM Manuel utilisateur

Detection Systems
Detection Systems 7090i Instructions de montage

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuel utilisateur

Siemens
Siemens FDM273 Manuel utilisateur