Telemark 851 Manuel utilisateur

MODEL 851 THICKNESS MONITOR
INSTRUCTION MANUAL
Software Version 2.0
Copyright © TELEMARK, 1990-2019 –All rights reserved
May 2019
telemark.com
Brand and product names are trademarks or
registered trademarks of their respective companies.
Current version of this manual can be found at
https://telemark.com/quartz-crystal-control/851-thickness-monitor/

Telemark Model 851 Thickness Monitor Instruction Manual
2 SPECIFICATIONS
SAFETY WARNING
HIGH (POTENTIALLY LETHAL) VOLTAGES ARE PRESENT WITHIN EVAPORATION SYSTEMS. GREAT
CARE MUST BE EXERCISED WHEN PERFORMING MAINTENANCE. HUMAN CONTACT WITH THE
VOLTAGES CAN BE FATAL.
WARRANTY
The 851 is guaranteed against faulty materials, function, and workmanship for a period of 12 months after
delivery from Telemark.
This warranty is valid only for normal use where regular maintenance is performed as instructed. This
warranty shall not apply if repair has been performed or an alteration make by anyone other than an
authorized Telemark representative or if a malfunction occurs through abuse, misuse, negligence, or
accident. No charge will be made for repairs made under warranty at Telemark’s facilities. Defective parts will
be repaired or replaced at Telemark’s option. Customer will be responsible for freight charges to Telemark’s
facility.
USER RESPONSIBILITY
The user is responsible for proper operation and ordinary maintenance of the equipment, following
procedures described in this manual, including reference documents. Proper operation includes timely
replacement of parts that are missing, broken, or plainly worn. If the user has a reasonable doubt about
understanding the use or installation of a component, Telemark or your local representative should be called.
It is vitally important that the user properly install the equipment as described in Chapter 3
(Installation) of this manual, with particular attention to the correct grounding methods described.
The Warranty will be void if the equipment is improperly installed and/or not adequately grounded.
SOFTWARE
Parts of the 851 software are made with open source software.
Linux is licensed under GNU General Public License (GPL), version 2.
All Xenomai code running in kernel space is licensed under the terms of the Linux kernel license, GNU
General Public License (GPL), version 2.
Xenomai libraries linked to application are licensed under the terms of the GNU Lesser General Public
License (LGPL), version 2.1.
Qt is licensed under GNU Lesser General Public License (LGPL) version 2.1.
The original “open source”source code is available from Telemark for a nominal fee.

Telemark Model 851 Thickness Monitor Instruction Manual
3 SPECIFICATIONS
TABLE OF CONTENTS
1 SPECIFICATIONS 5
PURPOSE 5
PACK LIST 5
SPECIFICATIONS 6
2 INSTALLATION 9
MOUNTING 9
PROPER GROUNDING 9
REAR PANEL CONNECTIONS 9
SENSOR HEAD INSTALLATION 13
SENSOR OSCILLATOR 14
INSTRUMENTATION FEEDTHROUGH 14
SENSOR CRYSTAL REPLACEMENT 15
3 PROGRAMING CONTROLS 16
PROGRAM BUTTONS 16
RESULTS 17
USB 17
RIGHT SIDE BAR BUTTONS 19
ENTERING ALPHA CHARACTERS 20
COPYING, DELETING AND MOVING 21
4 PROGRAMING 23
GETTING STARTED 23
SETUP 23
5 OPERATION DISPLAYS AND CONTROLS 32
INITIAL POWER UP 32

Telemark Model 851 Thickness Monitor Instruction Manual
4 SPECIFICATIONS
DISPLAYS 33
OPERATING CONTROLS 34
SIDE BAR CONTROLS 35
6 OPERATION 37
SIMULATE OPERATION 37
SELECTING A MATERIAL 37
STARTING A MATERIAL 38
STATUS DISPLAYS 38
MODES 39
SIMULATE 40
ERROR, WARNING, AND INFORMATION MESSAGES 40
7 TUNING 41
EMPIRICAL CALIBRATION 41
8 COMPUTER INTERFACE 43
GENERAL 43
RS-232 SERIAL INTERFACE 43
PROTOCOL 43
DATA TYPES 44
MESSAGE RECEIVED STATUS 44
DEBUG COMPUTER INTERFACE 45
INSTRUCTION SUMMARY 45
INSTRUCTION DESCRIPTIONS 46
9 TROUBLE SHOOTING 50

Telemark Model 851 Thickness Monitor Instruction Manual
5 SPECIFICATIONS
1
SPECIFICATIONS
PURPOSE
The 851 thickness monitor allows improved manual control of the vacuum film deposition process by
providing a direct display of film thickness and deposition rate during deposition.
Semiautomatic control of film thickness can be accomplished by utilization of the shutter control relay in the
851. The shutter control relay allows for direct operator control of the systems shutter and will also
automatically close the shutter when the deposition thickness equals a preprogrammed value.
PACK LIST
STANDARD ITEMS
The standard items included with the 851 monitor are:
Part No.
Quantity
Description
122-0851-1
1
Cable, Shielded Twisted Pair, 25 FT.
124-0909-8
1
Connector Kit, 9 Pin, D-Sub Male
124-0925-8
1
Connector Kit, D-Sub, 25pin, Male
200-0002-1
1
Telemark Product Manuals USB Drive
376-9010-1
1
Power Cord
851-0004-1
2
Chassis Ear, 851
851-0005-1
2
Chassis Leg, 851
861-0502-1*
1
Adapter, BNC Male/Male
861-0500-1
1
Oscillator Assembly
851-0600-4
1
Assembly, Chassis 851
* A BNC male/male adaptor is supplied for installations that have a 6 inch female BNC cable coming from the
vacuum system feedthrough.

Telemark Model 851 Thickness Monitor Instruction Manual
6 SPECIFICATIONS
ADDITIONAL ITEMS
Additional items that may be ordered and shipped with an 851.
1. Additional Oscillator and shielded RJ45 cable for sensor 2.
Part No.
Description
861-0505-1
Oscillator Kit
2. Each sensor needs a 6 inch coax cable to go between the oscillator and the feedthrough. The type
needed depends on the feedthrough connection.
Part No.
Description
880-2420-8
Cable, 6” BNC Male/Microdot
880-2421-1
Cable, 6" BNC Male/Male
3. Each sensor needs a 30 inch coax in-vacuum cable to go between the feedthrough and the sensor
inside the vacuum chamber.
Part No.
Description
880-2320-4
30 inch coax in-vacuum cable, Microdot
4. Telemark has a wide selection of O-Ring and CF flange feedthroughs available to pass the cooling
water and coaxial signal in to the chamber.
5. Crystals
Part No.
Description
880-0201-3
6MHz gold coated sensing crystals (Disc of 10)
880-0202-3
6MHz aluminum alloy sensing crystals (Disc of 10)
880-0203-3
5MHz gold coated sensing crystals (Disc of 10)
Please refer to the Telemark Price List for feedthroughs, more accessories and other products.
SPECIFICATIONS
INPUT POWER
Input Power Requirements
90-264 VAC, 47-63 Hz
PHYSICAL
Operating Temperature Range
0 to 50C
Physical Weight
4.3 LB
Physical Size
1/2 19” rackmount case
3 1/2” high x 8 1/2”deep
MEASUREMENT
Frequency Resolution
0.03 Hz @6.0 MHz
Mass Resolution
0.375 ng/cm2
Thickness Accuracy
0.5% + 1 count
Measurement Update Rate
Dynamically adjusted, 0.5 to 10 Hz
Display Update Rate
1 Hz
Sensor Crystal Frequency
5 or 6 MHz

Telemark Model 851 Thickness Monitor Instruction Manual
7 SPECIFICATIONS
DISPLAY
Thickness Display
Autoranging: 0.000 to 999.9 KÅ
Rate Display
Autoranging: 0.0 to 999 Å/sec
Time To Go
0 to 9:59:59 H:MM:SS
Crystal Health %
0 to 99%
Graphics Display
480x800 Color LCD touch screen with backlighting
COMMUNICATION
RS-232
Ethernet (TCP/IP)
MATERIAL STORAGE CAPACITY
Material
99, user definable
MATERIAL PARAMETERS
Material Name
12 character string
Sensor #
1 or 2
Material Density
0.80 to 99.9 gm/cm3
Acoustic Impedance
0.50 to 59.9 gm/cm2 sec
Tooling Factor
10.0 to 499.9%
Target Thickness
0.000 to 999.9 KÅ
Crystal Marginal %
0 to 99%
Crystal Fail
Switch, Stop
Backup Sensor #
1 or 2
Backup Tooling Factor
0 to 499.9%
The 851 also has a built in material library that contains many common material names along with their
density and acoustic impedance values.
INPUT/OUTPUT CAPABILITY
Discrete Input/Output
4 pre-programmed inputs
Input 1 = Start/Zero
Input 2 = Stop
Input 3 = Source shutter
Input 4 = Sensor shutter
Passive/Active is software selectable:
Passive TTL level inputs activated by a short across input pins.
Active inputs activated by 12 to 24 volts DC across the input pins.
4 pre-programmed outputs
SPST relay, 50VDC max, 2A max.
Output 1 = Target Thickness Reached
Output 2 = Crystal Fail
Output 3 = Source shutter
Output 4 = Sensor shutter
SENSOR CAPABILITY
Sensor Inputs
RJ45 connector
2 Standard

Telemark Model 851 Thickness Monitor Instruction Manual
8 SPECIFICATIONS
OSCILLATOR CAPABILITY
Oscillator Input
BNC, In a standard installation it is connected to a 6
inch coaxial cable, but the total cable length from
crystal head to oscillator must be between 24 to 48
inches. Please contact the factory for options when
the length is outside of this range.
Oscillator Output
RJ45 connector connects to the 851 via supplied 25
foot RJ45 shielded cable. Other lengths are available.
SHUTTER PARAMETERS
Source Shutter Relay Type
Normally open, normally closed, or none.
Sensor Shutter Relay Type
Dual or none.
UTILITY SETUP PARAMETERS
Crystal Frequency
5 or 6 MHz
Simulate Mode
On/Off
Interface Address
1 to 32
Attention Volume
0 to 10
Alert Volume
0 to 10
Alarm Volume
0 to 10
Touch Volume
0 to 10
Error Beep Volume
0 to 10
Data Points/Minute
30 to 600 PPM
Confirm Saves
Disable, Enable
Date
MM/DD/YY
Time
0 to 23:59

2
INSTALLATION
MOUNTING
The 851 is intended for rack mounting, but can be use on a tabletop. For maximum operating ease it should
be mounted at approximately eye level. If the 851 is mounted in a rack containing other heat generating
equipment, care should be taken that there is adequate ventilation to assure that the ambient temperature
does not exceed the 851’s ambient temperature rating.
PROPER GROUNDING
The 851 was designed for maximum noise immunity and in most cases will require no special grounding
precautions. In the event that noise sensitivity is noted in unusually noisy environments, more attention to
proper grounding may be required. It is important that the rack in which the 851 is mounted is tightly grounded
to the vacuum station. This grounding is best accomplished by a multipoint mechanical connection through
the structure itself or through grounding straps. Grounding straps should be as wide as practicable and can
be solid or braid.
A small diameter copper conductor does not create an effective ground.
Although the D.C. resistance measured with such a connection may be low, the inductance can be high
allowing rapidly changing currents to create large potential differences over the length of the ground wire.
Multiple current paths significantly reduce the inductance, and since the inductance of a conductor is in-
versely proportional to its radius, wide straps will have the lowest inductance.
In particularly noisy environments it is desirable to ground the 851 to the rack frame, or other good ground, by
means of a grounding strap connected to the grounding lug provided on the rear panel.
REAR PANEL CONNECTIONS
External connections are made through the rear panel (See figure 2-1).

Telemark Model 851 Thickness Monitor Instruction Manual
10 INSTALLATION
Figure 2-1, 851 Rear Panel
POWER
The power receptacle is an internationally approved type. A fuse and RFI filter are part of the power
receptacle assembly. The power plug must be removed to change the fuse.
USB
The USB port on the front panel is for connecting a USB drive to copy, backup and install; materials, system
settings, data log and new system software.
GROUND LUG
In particularly noisy environments the 851 should be grounded to the instrument rack, or other good ground,
by means of the grounding lug in the rear panel.
RS-232
The RS-232 connector is for connecting the 851 to a PLC or computer for remote operation and/or data
collection, see chapter 8. CTS and RTS are optional.
Figure 2-2, RS-232 Connection
Table des matières