Conference Table – Cable Housings, Switcher & TekTouchPad
TSC7 Cable Housings
Locate two positions, one at each end, within comfortable reach from all seated positions at the
conference table. Using the included cutout template, cut holes for mounting the cable housing. Insert
the cable housings into the table and attach the included mounting flanges into the highest accessible
slot on each end of the underside. Turn the thumb-screws until both feet are snug against the
underside of the table, and the cable housings do not move. Run all user cables through the central
opening in the cable housing, using one circular cutout per cable. Once all cables are in, insert the
included central plate and secure at both ends using the provided screws. To protect the cables from
damage, snap one plastic grommet into each hole in the cable housing.
1201-N+ Presentation Switcher
Attach the under-table mounting wings (included in switcher accessory box) to the 1201-N+ and fasten
to the underside of the conference table, approximately centered between the two cable housings.
Connect power cable to rear of 1201-N+ and run to nearest outlet, routed so that the cable does not
block other connections or dangle from table underside. Connect all user cables to the switcher’s HDMI
inputs as labelled. Connect one end of yellow HDBaseT cable to the 1201 presentation switcher’s
HDBT output port, and run the other end to the presenter podium.
TekTouchPad
Find a place within comfortable reach from as many seated positions at the conference table as
possible to place the mounting wedge for the TekTouchPad. Using a pencil, LIGHTLY trace a 4 ¾” tall
by 2 7/8” wide rectangle. In the approximate center of the rectangle, drill a 5/8” diameter hole for the
TekTouchPad cables to pass through. Using the traced rectangle as a guide, attach the wedge to the
table using the 4 provided wood screws. Attach the rectangular back plate, with mounting posts facing
outward and “Top ↑” text facing upward, using the two provided flat screws. Run the TekTouchPad
cable from the 1201 switcher up through the previously drilled hole and connect to the back of the
TekTouchPad. Ensuring wider portion is facing down, press TekTouchPad firmly onto 4 mounting
posts. Remove protective film once fully assembled and secure.
Podium / Credenza – Cable Housing, Switcher & HDBaseT Receiver
TSC7 Cable Housing
Locate a position within comfortable reach from behind the presenter podium or credenza without
obstructing workspace. Using the included cutout template, cut a hole for mounting the cable housing.
Insert the cable housing into the table or podium and attach the included mounting flanges into the
highest accessible slot on each end of the underside. Turn the thumb-screws until both feet are snug
against the underside of the table, and the cable housing does not move. Run all user cables through
the central opening in the cable housing, using one circular cutout per cable. Once all cables are in,
insert the included central plate and secure at both ends using the provided screws. To protect the
cables from damage, snap one plastic grommet into each hole in the cable housing.
1201-N+ Presentation Switcher
Attach the rack-mounting wings (included in switcher accessory box) to the 1201-N+ and fasten into
the equipment rack of the podium or table. Connect power cable to rear of 1201-N+ and run to side of
equipment rack, then down, so that the cable does not block other connections. Connect all presenter
sources included on the table (PC, Document Camera, Blu-ray Player, WiPS, etc.) to the 1201
switcher’s DMI inputs as labelled. Connect the 20’ flexible HDBaseT cable at one end to the HDBaseT
output of the 1201 switcher, and at the other end to the HDBaseT wall plate.
HDBaseT Receiver
Install receiver in equipment rack directly beneath 1201 switcher, connect HDBaseT cable from
Conference Table to input, and connect HDMI & RS232output to 1201 HDMI input as labelled.