Tektronix K475 Manuel utilisateur

Instructions
K475
Workstation Tower
070-8847-02
*P070884702*
070884702
www.tektronix.com

Copyright ©Tektronix, Inc. All rights reserved.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes
that in all previously published material. Specifications and price change privileges reserved.
Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.

WARRANTY
Tektronix warrants that the products that it manufactures and sells will be free from defects in materials and
workmanship for a period of one (1) year from the date of shipment. If a product proves defective during this
warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor,
or will provide a replacement in exchange for the defective product.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration
of the warranty period and make suitable arrangements for the performance of service. Customer shall be
responsible for packaging and shipping the defective product to the service center designated by Tektronix, with
shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a
location within the country in which the Tektronix service center is located. Customer shall be responsible for
paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate
maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage
resulting from attempts by personnel other than Tektronix representatives to install, repair or service the product;
b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any
damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been
modified or integrated with other products when the effect of such modification or integration increases the time
or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS
OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’
RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND
EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY.
TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR
THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.


K475 Workstation Tower Instructions i
Table of Contents
General Safety Summary ii...................................
Contacting Tektronix iii.............................................
Introduction 1..............................................
Base Assembly 5............................................
Drawer Shelf and Drawer 10...................................
Keyboard Shelf 14...........................................
Half Shelf 15................................................
Second Half Shelf 17..........................................
Leg Caps 18.................................................
Nylon Straps 19..............................................
Customization 20............................................
Specifications 21.............................................
Replaceable Parts 22..........................................
23...................................

ii K475 Workstation Tower Instructions
General Safety Summary
Observe these safety precautions when using the K475 Workstation Tower.
Keep the K475 Level
Keep the K475 level at all times, especially when it is loaded with instruments.
The tower is designed to be very stable, but it can fall over if tilted to extremes.
Observe this precaution especially in these cases:
HWhen rolling the tower across uneven floors.
HWhen rolling the tower through doorways with uneven thresholds.
HWhen lifting the tower wheels over cables.
HWhen rolling the tower up or down ramps.
Do Not Top-Load the K475
Do not load the top shelves of the K475 while leaving the bottom shelves empty.
That makes the tower top-heavy and easier to tip over. Load the top shelves only
if the bottom shelves are also loaded.
Do Not Overload Shelves
Do not put more weight on any tower shelf than is listed in the specifications.
Load the top of the tower evenly.
Observe Electrical Safety
All parts of the tower must be treated as electrical conductors, even if they
appear to be nonconducting. Do not rely on the casters to provide insulation
between the tower and the surface it stands on. Conversely, do not rely on the
casters to provide a conductive ground path for the tower.
Test the Stability of Custom Configurations
Changes in shelf location and loading can affect the balance of the tower. If you
arrange the shelves differently from the configuration described in this manual,
test the tower carefully for stability before using it.

K475 Workstation Tower Instructions iii
Preface
Contacting Tektronix
Phone 1-800-833-9200*
Address Tektronix, Inc.
Department or name (if known)
14200 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
Web site www.tektronix.com
Sales support 1-800-833-9200, select option 1*
Service support 1-800-833-9200, select option 2*
Technical support Email: techsupport@tektronix.com
1-800-833-9200, select option 3*
6:00 a.m. -- 5:00 p.m. Pacific time
*This phone number is toll free in North America. After office hours, please leave a
voice mail message.
Outside North America, contact a Tektronix sales office or distributor; see the
Tektronix web site for a list of offices.

Preface
iv K475 Workstation Tower Instructions

K475 Workstation Tower Instructions 1
Introduction
The Tektronix K475 Workstation Tower requires some assembly. This manual
tells how to assemble and use the tower.
You can assemble the K475 Workstation Tower by yourself, but it is easier if you
have another person to help you.
You will need a large flat area to assemble the tower. The area should be level
and large enough to move the various parts into place. A carpeted floor space is
ideal.
Tools
You will need a 3/4 inch (19 mm) open-end wrench, or an adjustable wrench that
can be adjusted to that size.
Other tools are included with the K475 Workstation Tower. These include a
3/16 inch Allen wrench and a circular bubble level.
Parts Identification
The large pieces of the K475 Workstation Tower are packed separately in the
shipping carton. A bag of small parts is packed in a box with these instructions.
The included tools are also packed in this bag. Figure 1 on page 2 shows the
small parts you will be using.
Table 1 on page 3 lists all the parts needed to assemble the tower, including the
large pieces and assemblies. Take an inventory now to familiarize yourself with
the parts for the assembly process.

Introduction
2K475 Workstation Tower Instructions
1/4--20 Button Head
Screw, 1/2 inch length
1/2 inch Split Lockwasher
3/16 inch Allen Wrench
Short Rail
1/4 inch Tooth Lockwasher
Circular Bubble Level
Press-On
Probe Holder
Figure 1: Identification of Small Parts
Table des matières