TC Communications TC8927 Manuel utilisateur

TC8927
6+2-Ch. Paging System
w/ Dry Contact
User Manual
MNL-89270-01-00

2 TC8927 Rev 1.0 User Manual
All Rights Reserved
Copyright © 2019 by TC Communications. Products described in this publication are protected
by one or more U.S. and foreign patents.
Trademarks
The TC Communications® logo is a registered trademark.
JumboSwitch® is a registered trademark of TC Communications.
Other product and brand names may be trademarks or registered trademarks of their respective owners.
Documentation Disclaimer
This document is provided “as-is” and is to be used only as a general guide. TC Communications disclaims all
warranties, express or implied, regarding the accuracy of the information. TC Communications shall not be liable for
any indirect, special, incidental, or consequential damages (including damages for loss of business, loss of profits,
loss of business information, business interruption or other pecuniary loss) arising out of errors in this document.
The information given in this document is reviewed regularly and any necessary corrections will be included in
subsequent editions. We appreciate any suggested improvements. We reserve the right to make technical
improvements without notice.
Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized
except where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the
purposes of patent application or trademark registration. This document contains proprietary information, which is
protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced or
translated to another language without the prior written consent of TC Communications.
Record of Revisions
Revision Date Description of Changes
1.0 06/04/19 Initial Release of TC8927.
TC Communications
17881 Cartwright Road
Irvine, California U.S.A. 92614
Tel. (949) 852-1972
Fax (949) 852-1948
E-Mail: sales @tccomm.com
Website: tccomm.com

TC8927 Rev 1.0 User Manual 3
Guide to Alert Symbols
These alert symbols are used in Caution, Warning, and Danger notes.
Symbol Meaning
Pinching or crushing hazard
Electrical hazard.
Equipment alert: be careful of
damage from static electricity
General alert: used for all
other hazardous conditions
(referring to people, not
equipment).

TABLE OF CONTENTS
TOC-1 TC8927 Rev 1.0 User Manual
1Introduction
1.1 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.2 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.2.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.2.2 Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.3 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
2 Installation
2.1 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.2 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.3 Equipment Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.4 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.5 Dry Contact Alarm Relay (DCAR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.6 System Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.7 System Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.7.1 Front Panel (Analog Pin Assignments) . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.7.2 Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.7.3 Electrical Signal Interface Connection & Pin Assignments . . . . . . . . 2-6
5 Troubleshooting
5.1 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.2 All LEDs are OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.3 Alarm LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Appendix A 19” Rack Mount Card Cage
A.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
A.2 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
A.3 Chassis Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Appendix B Return Policy
B.1 Return Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
B.1.1 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
B.1.2 Limitation of Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2

TC8927 Rev 1.0 User Manual 1-1
Chapter 1 Introduction
In this chapter:
•Product Description, on page 1-1
•Specifications, on page 1-5
1.1 General Information
This manual is intended to describe the features and functionality in addition to
aiding in the planning, configuring, commissioning and maintaining of the
TC8927 Paging System with Dry Contact.
1.2 Product Description
The TC8927 bridges/broadcasts analog audio and dry contact from a central location
to remote sites. An incoming analog/dry contact signal coming into the primary host
port will be broadcast to 6 slave ports. A backup host port is available for
redundancy. The dry contact channel is typically used to actuate the end equipment
to broadcast the audio. When both Primary and Backup host ports receive signal,
Primary will take precedence.
Diagnostic LEDs are available to quickly identify issues with your analog lines.
Figure 1-1 TC8927 6+2 Channel Paging System with Dry Contact

Chapter 1 Introduction Product Description
1-2 TC8927 Rev 1.0 User Manual
Figure 1-2 TC8927 Front Panel LED Definitions

Chapter 1 Introduction Product Description
TC8927 Rev 1.0 User Manual 1-3
Figure 1-3 TC8927 Rear Panel LED Definitions
1.2.1 Features
• 2 Channel Inputs as Host Ports
6 Channel Outputs as Slave Ports
• Modular Design with 8 Channels per Module
• 64K Full Bandwidth Voice Transport
• Passes All Tones used for FSK, EIA Tone Control/Remote and Paging
• Supports Pilot/Guard Tone Operation
• Optional Power Redundancy
• 1U or 4U Rack Mount or 1S Standalone Chassis
• 12VDC, 24VDC, -48VDC, 125VDC

Chapter 1 Introduction Product Description
1-4 TC8927 Rev 1.0 User Manual
• LEDs for Analog Volume, Alarm Status, Channel Release Tone, and
Loopback
1.2.2 Applications
The TC8927 bridges/broadcasts analog audio and dry contact from a central location
to remote sites.
Figure 1-4 Typical Application using the TC8927

Chapter 1 Introduction Specifications
TC8927 Rev 1.0 User Manual 1-5
1.3 Specifications
Connection Capacity
600Ω (4-Wire) 2 ports (Host), 6 ports (Slave)
Dry Contact 2 ports DCD (Host), 6 ports DCC (Slave)
Electrical
Analog/Dry Contact Connector RJ-11
Impedance 600Ω
System
Visual Indicators System: PWR A, PWR B, Vcc, ALM
Paging: P#, R-Tone
Channel Status:
TX (1 each Ports 1-8)
RX (1 each Ports 1-8)
Diagnostic Functions Local Loopback
Power Source
Standard 12VDC @500mA
Optional 24VDC, -48VDC, 125VDC, or 100/240VAC
Temperature
Operating -10°C to 50°C
(Optional Hi-Temp Version) -20°C to 70°C
(Optional Extreme-Temp Version) -40°C to 80°C
Storage -40°C to 90°C
Humidity 95% non-condensing

Chapter 1 Introduction Specifications
1-6 TC8927 Rev 1.0 User Manual
Physical (Rack mount 1U “Pizza Box”)
Height (4.3 cm) 1.7"
Width (48.3 cm) 19"
Depth (26.7 cm) 10.5"