TB-Electronics F-SCAN3 NT Manuel utilisateur

- 1 -
Frequency Synthesizer
F-SCAN3 NT
Firmware Version FS3 V1.00B14
INSTRUCTION MANUAL
This symbol identifies the equipment as type B
Attention: CONSULT ACCOMPANYING DOCUMENTS

- 2 -
ENGLISH
WARNING AND NOTES .................................................................................................................. - 3 -
Preface ............................................................................................................................................. - 3 -
Introduction ...................................................................................................................................... - 3 -
The shipment from the factory includes: ........................................................................................... - 5 -
Elements for operation ..................................................................................................................... - 6 -
Signal forms delivered to Multi-signal-output port ............................................................................ - 7 -
Factory settings ................................................................................................................................ - 8 -
First steps to start F-SCAN3 NT ....................................................................................................... - 9 -
The menu 123 ................................................................................................................................ - 10 -
How to select a program from the menu “123“ ............................................................................... - 11 -
How to input a frequency value ...................................................................................................... - 13 -
The properties of frequencies ......................................................................................................... - 13 -
The menu DIRP ............................................................................................................................. - 16 -
How to prepare for a DIRP and run it ............................................................................................. - 18 -
EAP (ELECTRO-ACUPUNCTURE) measurements...................................................................... - 19 -
EAP- functional test ........................................................................................................................ - 19 -
How to complete an EAP-table ...................................................................................................... - 20 -
The menu SETTINGS .................................................................................................................... - 21 -
CHIPCARD option .......................................................................................................................... - 22 -
CHIPCARD option .......................................................................................................................... - 23 -
Use of the ChipCard PLUS ............................................................................................................ - 23 -
How to format, integrate and use programs from other sources .................................................... - 24 -
How to start, pause, or stop a program .......................................................................................... - 25 -
Technical data ................................................................................................................................ - 26 -
DEUTSCH
Warnungen und Hinweise .............................................................................................................. - 28 -
Vorwort ........................................................................................................................................... - 28 -
Lieferumfang des F-SCAN3 NT .................................................................................................... - 30 -
Bedienelemente ............................................................................................................................. - 31 -
Signale am Multi-Ausgang OUT (CON1) ........................................................................................ - 32 -
Gerätevoreinstellungen .................................................................................................................. - 33 -
Erste Schritte – Einschalten ........................................................................................................... - 34 -
Das “123” - Menü ........................................................................................................................... - 35 -
Programmauswahl im “123” - Menü ............................................................................................... - 36 -
Beispiel für die Eingabe einer Frequenz ......................................................................................... - 38 -
Eigenschaften von Frequenzen ...................................................................................................... - 38 -
Das SWEEP Menü ......................................................................................................................... - 40 -
Das DIRP Menü ............................................................................................................................. - 41 -
EAP-Messungen /Elekroakupunktur) ............................................................................................. - 44 -
Option ChipCard ............................................................................................................................ - 48 -
Ein Programm starten, pausieren oder stoppen ............................................................................. - 50 -
Technische Daten .......................................................................................................................... - 51 -
Declaration of Conformity / Konformitätserklärung ......................................................................... - 52 -

- 3 -
WARNING AND NOTES
Preface
One of our prime objectives as a Swiss company is the development and manufacturing of precise and reliable
products based on many years of experience. Some of our products are well known and utilized internationally.
As a small company we can react fast to changed customer requirements. May your use of the F-SCAN3 NT be
beneficial.
Introduction
The FREQUENCY SYNTHESIZER F-SCAN3 NT has been optimized for stationary use. The device is a member
of the F-SCAN product family.
The colour touch screen, combined with the latest functional technology, offers a user-friendly system with
outstanding performance.
The device generates precise sine signals (permanent positive) and square signals (zero – symmetric or
permanent positive) and sends them under software control to an output port.
A special feature is the integrated SMART-WAVE. If selected, it will modulate the assigned wave form with a
high frequency.
Special accessories, like the Magnetic Coil Adapter, can be connected to the PowerPort without a separate
amplifier.
The intensity of square wave signals can, depending on the application, either be adjusted manually or
automatically.
A TIMER can be assigned individually to each frequency or as a global function.
The settings for the special application modes WOBBLE, ENVELOPE, and for the signal amplitudes, are also
accessible.
The DIRP-function (Dual Integration Resonance Procedure) can be used to scan automatically for resonance
answers to frequencies send to a user. The procedure can be used in the complete frequency band of the
device. Graphical edit functions support the analysis of the DIRP – results.
SUB SCAN mode for specific scans which helps to detect resonants for pre-selected substances.
An EAP (electro acupuncture) capability is integrated for diagnostic use by experts. The optional EAP-SET is
needed to use this feature.
A broad band application of frequencies (SWEEP) can be selected from an individual touch screen window.
WARNING: The F-SCAN3 NT generates frequencies. The use of
other accessories than those supplied with the unit – or described
here – could cause malfunctions or become a hazard to the user.
The warranty would be forfeit.
ATTENTION: The unit, all accessories, connectors and cables must be
visually inspected for damage frequently. We recommend a yearly
functional test by a professional.
ATTENTION: The device’s integrated functions allow biological tests and
applications described in the publications of Dr. H.R.CLARK. They are
also suitable for applications commonly named after R.R.Rife. The F-
SCAN3 NT is not a medical device. It is used under the sole
responsibility of its operator WITHOUT LIABILITY TO THE
MANUFACTURER.

- 4 -
The device provides a large storage capability of 100 applications of up to 50 frequencies each, complete with
names and all individual settings, or the complete results of DIRP runs and EAP analysis, can be stored. In
addition, up to 460 user defined frequency sets (up to 30 values each) can be saved in the F-SCAN3 NT memory.
A powerful state of the art 32-bit micro-processor controls all functions.
Customized ChipCard-functions support the data transfer between our products F-SCAN3, F-SCAN4, F-SCAN5,
F-SCAN MOBILE, F-SCAN COMPACT and the MinDevice.
We are convinced that the touch panel operation will be mastered by all users without problems.

- 5 -
The shipment from the factory includes:
F-SCAN3 NT FTB136 in carrying case FTB333 with instruction manual
Wall charger FTB224
Stainless steel electrodes FTB202A
Application cable for electrodes FTB308
2 sets of self-adhesive pad-electrodes FTB041
DIRP sensor FTB303
USB cable FTB223

- 6 -
Elements for operation
A touch on this icon
switches the unit OFF.
Mini-USB connector
CON1: Multi-signal
output port
ON switch
CON3: PowerPort
CON2: not applicable
Slot for ChipCard

- 7 -
Signal forms delivered to Multi-signal-output port
SINE (DC-OFFSET)
10Vpp
SQUARE, 0-symmetrical,
Full Wave 0Vpp to 24Vpp
SQUARE, permanent positive, Half Wave
0Vpp to 12Vpp (DC-OFFSET)
SMART, permanent positive, Half Wave
0Vpp to 12Vpp (DC-OFFSET), a high
frequency covering the application frequency.

- 8 -
Factory settings
Language on screen: English or German
Application time per frequency: 3:00 Minutes
(adjustable between 0:30 and 59:59)
Signal strength: 80% of maximum of 12Vpp
(adjustable +/- in steps of 1%)
Signal form: AUTO (Sine, Square Full Wave, Half Wave, SMART and OFF selectable).
AUTO = Square Half Wave if lower than 65000 Hz, Sine above 65000 Hz.
Memory of ”123“ is empty.
Memory of ”ABC“ is empty and locked.
Connector 3.5mm CON1 :
At this connector is the standard multi signal output available with a bandwidth up to 3 MHz. Standard
application parts may be connected.
Connector 3.5mm CON2 :
This connector is not applicable.
Connector 2.5mm on CON3 :
Connector for the PowerPort. Application parts such like magnetic field electrode must be connected here. No
standard application parts may be connected.
RESET: If device cannot be operated from the touch screen due to unknown reasons, the RESET button on
the rear panel can be pressed briefly to shut down the unit. Use a “tooth pick” or “match” carefully.
Such effects may happen if the battery has not been charged correctly or a data transfer from software was
interrupted.

- 9 -
First steps to start F-SCAN3 NT
- Connect the mini usb cable to the device and plug the wall charger into a wall outlet with a reading
between 100 VAC up to 240 VAC.
- Touch the ON switch on the side.
The screen must show the stand by screen with the battery symbol top right flashing yellow.
The information displayed means:
- SERIAL: Serial number of device
- ONS: Number of uses
- Ds Number of DIRPs
- FLASH ID: identifies the type of internal memory.
FFFFFFFF would indicate a memory defect. The device must then be checked by a professional.
- V1.00Bxx Version of software active in the device.
The opening screen, as shown above, offers a menu of 5 or 6 options. One has to be selected with the finger to
continue the setup of the F-SCAN3 for operation. The menu button EAP is enabled only if the device is
purchased with the EAP option.

- 10 -
The menu 123
The menu “123” must be used to create and run individual programs with the ability to enter random
frequencies in the range from 0.01 Hertz up to 3 MHz (Megahertz).
The F-SCAN3 NT offers 100 storage positions for programs of between 1 and 50 frequencies. The end of
each program is a value of 0 Hertz (Hz).
Each program can be named individually.
A number of parameters can be assigned to each frequency value:
- Run time (TIME)
- Signal form (Auto, Sine, Square Half Wave, Square Full Wave, SMART and OFF)
- WOBBLE (Output swings around the target frequency)
- ENVELOP (Amplitude oscillates between 0Vpp and maximum)
- Amplitude (signal strength) of sine wave and square wave.
All frequencies are listed on the right-hand side on the display in groups of 10. If a frequency is a result of a
DIRP, the associated measured value (MV) is also indicated. The selected frequency is displayed in orange.
The vertical arrows can be used to show up to 5 blocks of memorized frequencies of a program.