Tanpera PROWATT Manuel utilisateur

ELECTRICAL WATER HEATER PANEL USER MANUAL
www.tanpera.com
Lcd Screen Control Panels

YOU SHOULD READ THE INFORMATION IN THIS MANUAL CAREFULLY
TO GET THE BEST EFFICIENT USE OF OUR CONTROL PANELS.
THIS MANUAL IS A RELIABLE SOURCE THAT CAN HELP YOU SOLVE ALL
YOUR PROBLEMS RELATED TO CONTROL PANELS..
THIS USER MANUAL :
Will help you use the control panels safely and accurately.
• Includes commissioning, installaon and maintenance of control panels.
• Explains the transportaon, storage and warranty condions of the control panels.
• Read the user manual before operang your control panel.
• Observe the safety informaon in parcular.
• All operaons on the control panel must only be carried out by authorized persons in accordance
with the informaon in the user manual.
• No warranty is granted for repairs or alteraons carried out by unauthorized persons.
The user manual should be close to the control panel and easily visible and accessible.
1 We reserve the right to make changes in technical informaon.

1. PLEASE PRESERVE THIS DOCUMENT.
This symbol is used to alert the user to “personal hazard.”
This symbol is used to alert the user to “dangerous voltage ”.
1. Be sure to read the user manual before operang the panel.
2. Follow the instrucons in the user manual.
3. Pay aenon to the front panel on the control panel. The front panel may break when impacted.
4. Do not install the panel directly where water can be absorbed. Do not pour water and any liquid
into the panel cabinet. In case the panel is touched by water, cut o the electricity from the main
fuse/switch and contact the authorized person or instuons.
5. Do not operate the panel if any foreign objects get inside the panel cabinet. This may result in
electric shock or damage to the panel. Have the panel checked by authorized personnel.
6. To prevent re occurence, keep ammable liquids and materials or pure ame away from the
panel.
7. The electrical connecon of the panel must be connected to the main switch socket located
inside the panel as shown in this manual. Failure to do so may result in serious injury or death from
electric shock.
8. If the power cord is damaged, it must be replaced by a new one suitable to the original by an
authorized provider.
9. Do not use damaged or torn cables in the electrical connecons. Do not place heavy objects on
the power cord and do not damage or operate on the power cord. Cables can be damaged and
cause re or electric shock. In such cases, please contact the authorized person or instuons.
10. See praccal troubleshoong in case of a fault and call for service if necessary. Never aempt to
repair your panel yourself.
11. Do not dispose of your panel with general household waste. Comply with local laws and
regulaons for disposal
Failure to follow the safety instrucons will void the warranty condions..
We reserve the right to make changes in technical informaon. 2

3 We reserve the right to make changes in technical informaon.
As long as installaon, commissioning and service are carried out by authorized personnel, your
panel does not pose any safety risks.
2. Warnings about situaons that may be harmful to human or environmental health:
• It may cause burns, electric shock or death.
• Disconnect electrical connecons before any work on the panel.
• Make sure the panel is ground-connected.
• Loosening of the electrical connecons may result in electrical leakage and injury.
- The methods for starng and stopping the panel are described in the manual.
- During the re-commissioning of the panel, the secons that have been processed must be
monitored.
- Cauon should be taken against water leakage and splashes in the panel, and if possible,
a “leakage current relay” should be installed.
- All electrical cables must be connected to the panel using a protecve sheath.
3. Unacceptable Acons:
Design changes / modicaons to the control panel must only be made with the permission of
the manufacturer. If other parts are used on the control panels, the manufacturer shall not be
liable for the consequences of the changes.
4. Special Safety Equipment and Recommendaons on the Panel:
It may cause electric shock and death.
Improper intervenon in the control panel may cause damage to it.
In the control panel, there are protecon panels made of insulang plexiglass material which are
designed as an outline to protect the electronic card from external factors.
The panels must not be removed by unauthorized persons and no intervenon should happen to
the electronic card.
5. Informaon on Ecient Use of Energy Savings:
The control panel you have purchased does not consume energy by itself, but pumps and motors
are energy consuming products for their intended use.
Proper use; extremely important for personal reasons and naonal economy.
Resistance suitable to the control panel should be used.
All electrical connecons are made correctly and in accordance with the instrucons; thus, loss
and leakage electricity could be prevented.

We reserve the right to make changes in technical informaon. 4
6. Lifeme:
The service life of the product as determined and announced by the Ministry of Industry
(the period of having spare parts necessary for the device to perform its funcons) is 10 years.
7. TRANSPORT / STORAGE / INSTALLATION
7.1. Transport:
Handle the control panels carefully and prevent them from falling. The control panels are
shipped in a cardboard box suitable for their size. Do not remove the control panels from the
cardboard box during transportaon.
7.2. Carriage and Shipping:
Necessary precauons should be taken to ensure that the panel is not damaged during shipping
and is not aected by bad weather condions.
It should be checked that the panel received corresponds to the model ordered and that there is
no damage during transportaon.
If there is damage or a missing part/defect in the panel. damage assessment report should be
made to the transport company along with a wrien report to our company.
7.3. Storage:
If the control panel is not to be installed immediately; Do not store in humid environments.
Do not place weight on control boards. Keep control panels where rain and water cannot enter
them.
It should be noted that the panels may be damaged if the instrucons are not
followed during installaon..
If the instrucons are not followed during installaon, it should be noted that
serious injury and death may result from electric shock.
The control panel must be installed in such a way that no load is placed on it.
When mounng the control panel, it must be mounted to the nuts on the rear side with the
appropriate screw.
The panel must not be drilled with another screw behind the panel. This could damage the
electronic card.
The electrical connecon of the control panel must only be carried out by authorized persons
while taking the necessary safety precauons.

8. OPERATING
The electrical connecons of the control panel should be checked.
It should be checked that that the control panel cover is closed.
It should be checked that the electrical energy is not interrupted and the phases are complete.
Control panel sengs should be made according to the resistance to be used.
You can nd the appropriate sengs for the panel you are using in the sengs entry menu.
9. MAINTENANCE
9.1. Monthly Maintenance:
Cut o electrical power before starng maintenance.
The control panel’s electrical connecons should be checked for loosening.
The control panel grounding line must be checked. Check that there is no discoloraon in the
electrical cables due to wear, puncture or heang.
10. GENERAL INFORMATION
The control panel that you have purchased is designed based on a microcontroller.
All control operaons on the panel are done electronically and stored.
The electronic board inside the control panel is manufactured with high technology SMD material.
An SMD led lamp and LCD display with minimum energy consumpon are used as indicators.
5 We reserve the right to make changes in technical informaon.

Press SET buon to enter the authorized seng menu.
CONTROL FRONT PANEL INTRODUCTION AND USAGE
1 : 4X20 Blue LCD Screen.
2 : The up arrow key allows you to change the page on the main screen and move up in the menu.
3 : The reset buon is used to reset errors and silence the buzzer..
4 : The down arrow key allows moving down the menu.
5 : Set buon is used to enter the menu and save the changes made in the menu.
6 : The ESC key allows you to return to the previous menu and exit the current menu.
7 :1. Lights when the heater is switched on.
8 :2. Lights when the heater is switched on.
9 : Lights when there is an error in the system.
10:3. Lights when the heater is switched on.
11:4. Lights when the heater is switched on.
12: Lights when there is a phase fault in the system.
We reserve the right to make changes in technical informaon. 6

SETTING ENTRY MENU
Temperature Sengs
Set Value : 50°C
Hist Value : 05°C
Max Value : 65°C
In the Sengs menu, SET buon is pressed to acvate the Temperature Sengs. Set Value starts
ashing and its temperature value is entered with up / down buons and saved by pressing SET
buon. If the inserted value is above the set temperature, the outputs are automacally switched
o. Hist Value temperature starts to ash. With the help of Up / Down keys, the desired value is
entered and it is saved by pressing SET buon. Max value starts to ash. Max temperature value is
entered with the help of Up / Down keys. Then Press SET buon to save.
In this menu, past events are displayed on the screen with the date and me of occurrence.
The last 20 events are displayed, press the up arrow to view the next event.
This menu is used to restore the factory sengs.
This menu is used to access the device memory with the authorized password.
PAST EVENTS
27.04.2014 15:38
1- Lower Voltage
FACTORY SETTINGS
ENTER THE PASSWORD
This menu is used to select acve and passive devices connected to the device accessible with the
authorized password.
EQUIPMENT SETTINGS
7 We reserve the right to make changes in technical informaon.

Voltage Sengs
Upper Voltage =
Lower Voltage =
Press the SET buon once to enter the sengs. Authorized Password screen is displayed and the
password is enetered with the help of Up / Down keys. The Voltage Sengs menu appears.
To change the voltage sengs, press SET buon and upper voltage will start illuminang and
the value can be changed with the up / down keys. Aer the change is completed, SET buon is
pressed and the value is stored. The lower voltage will start to illuminate.
If you do not want to change the voltage sengs, press the Up arrow key to select Current
Sengs and press the SET key.
When the current sengs text is displayed, if you want to see or change the values, press SET
buon to enter the menu and the above screen is displayed. Upper current text starts ashing.
Enter desired value with Up / Down arrow and press SET buon. The lower current set starts to
ash, the same operaon is done for the lower current seng and saved by pressing the SET
buon.
Aer the current sengs are completed, press ESC key to go back to the menu and press the Up
arrow key to reach the Temperature Sengs menu and press the SET key.
Current Sengs
Upper current =
Lower current =
We reserve the right to make changes in technical informaon. 8

Parameters and descripons in the Time Sengs menu;
Voltage Hist: Factory set to 5V, no change required.
Voltage On Time: This is the voltage switch-on me seng. It is the waing me for automac
reset when the measured voltage values are again within the desired limits whenever the system
is in fault condion due to voltage error.
Voltage O Time: This is the voltage faulty switch-on me seng. It is the waing me to switch
o when the measured voltage values are out of the set values. It is necessary to prevent the
motor from switching o frequently in case of instantaneous uctuaons.
Inrush Time: Inrush current me seng. The current cannot be compared with the current set
values during the set period/me.
Temperature Time: When the measured temperature values exceed the set temperature values,
it waits for the me set here and then goes into error status.
Temperature Hist: The system that has failed due to high temperature must fall down to the set
degree for a system restart.
Current Delay: Current fault trip me seng. When the upper or lower current exceeds the set
value, the motor stop me seng is set in seconds.
Vibraon Time: If the measured vibraon value is above the set vibraon value, it waits for the set
me here.
Switching: This is the seng for liming the number of switches. It is the seng of liming the
number of mes the motor starts and goes out in 1 hour.
To change the voltage hysteresis value, SET buon should be pressed. Voltage hist starts to ash
and the value next to it can be changed with up / down keys. Aer the change is completed, press
SET buon to save the value to memory. The up / down buons are used to nd the parameter
we want to change and the parameter is highlighted. Press SET buon and the text starts to ash,
this value can be changed.
Time Sengs
Voltage hist =
9 We reserve the right to make changes in technical informaon.
Table des matières
Autres manuels Tanpera Chauffe-eau
Manuels Chauffe-eau populaires d'autres marques

Kenmore
Kenmore 153.582400 Manuel utilisateur

Applimo
Applimo Edel AIR Manuel utilisateur

STIEBEL ELTRON
STIEBEL ELTRON Eltronom SHU 5 S Manuel utilisateur

clage
clage E-Mini Series Manuel utilisateur

Toyotomi
Toyotomi Oil Miser OM-180 Manuel utilisateur

Bradford White
Bradford White EF Series Manuel utilisateur