Syncronorm SyncroDAC Manuel utilisateur

SyncroDAC
Operating Manual
www.syncronorm.com info@syncronorm.com#liquidinspiration

+49 (0)2932-89786 0
+49 (0)2932-89786 299
www.syncronorm.com
Syncronorm GmbH
Graf-Gottfried-Strasse 122
59755 Arnsberg | Germany
ABOUT US
Syncronorm GmbH are highly motivated producers of high-end multimedia show design software,
which features a most unique real-time 3D visualizer. Our dynamic & experienced team thereby
operates on a world-wide scale, providing you with the best software & hardware solutions tting
to your dedicated project. From show-design, training-programs, instant support & consulting
to continuously soft- & hardware development, the team at Syncronorm is eager to realize your
visions. Syncronorm provide the most established & renowned products for the entertainment- &
water-show sectors within the industry and beyond.

Version: April 2021
SYNCRODAC
The SyncroDAC is a Universal Network Decoder to drive electronic control components in a multi-
media show environment. The Decoder supports all Major Protocols: Analog (0...10V) or Digital
(DSI or DALI). SyncroDAC is the perfect tool to integrate analog VFD´s into a Syncronorm
Depence Network as well as to control any 0...10V, 1...10V, DSI, DALI or PWM Output.
The SyncroDAC is a DMX RDM compatible interface and features four DMX personalities. Thus,
the Decoder can be operated with standard DMX or bidirectional DMX RDM and is fully compatible
with the Syncronorm RDM Browser application.
4 Channel DMX to Analog Decoder

(C) 2021 Syncronorm GmbH
4
You made a great choice by purchasing Syncronorm‘s SyncroDAC hardware unit. Prior to
commissioning the unit, please read the following instructions of use carefully and fully familiarise
yourself with the unit. Ensure that all work on and with this unit is only carried out in accordance to these
instructions. Adhere to the safety information for the correct and safe use of the unit. Keep these
instructions in a safe place! Please also hand over the instructions, when passing the unit on to a new
owner.
Preface
This document is a guideline for controlling the hardware of Syncronorm‘s fountain control systems. The
information contained in this manual will give you a sucient understanding of this product, helping you
to use the unit correctly and eectively. Adhere to all instructions contained in this manual, when
installing and operating this unit. Every person working with this equipment must read this manual
before installation and commissioning of the equipment/device. Every person working with this device/
equipment must read the manual before starting to work. Even personnel working with this device only
occasionally must read and understand this manual before beginning to work. This manual must always
be available at the site, where the device is located. Every user of this device must be aware of the
location of the manual.
Technical Data
WELCOME TO SYNCRONORM
Dimensions
Weight
Protection Class
Power Supply
Operation Temperature
Certification
Outputs
Inputs
Order Number
80x90x58 mm DIN RAIL 4U
0.20 kg
IP 20
24V DC*
0.. 40° / 0.. 80% humidity
CE
4 Outputs 0..10V or 1..10V DC, DSI, DALI, PWM max 2mA
DMX RMD
SN-STDAC24
SyncroDAC

(C) 2021 Syncronorm GmbH 5
Checking the Scope of Delivery
Please check that the scope of delivery is complete. Keep the packaging for later transport. If
Scope of delivery:
1x SyncroDAC 4 Channel DMX to Analog Decoder
Please note that a programming adaptor (3000P) is not included with DIN rail mount devices. A
programming adaptor (required to set DMX start addresses and operating options) must be ordered
separately.
This unit requires the SyncroTools DMX address board (SN-STADRB) (not included).
Intended Use
The SyncroDAC, in the following referred to as „unit“, may only be used as specied as follows:
Converting ArtNet signal to DMX-RDM signal
Safety Information
Danger to persons and assets may emanate from this unit, if it is used in an improper manner or not
in accordance with its intended use, or if the safety instructions are ignored. This unit must not be used
by children under the age of 18. Persons with impairments or lack of experience and knowledge may
use the unit, as long as they are supervised and instructed on how to use the unit safely and are able to
understand the potential risks. Do not allow children to play with this unit. Do not allow children to clean
or maintain the unit.
Correct electrical Installation
• Electrical installations must meet the national regulations and may only be carried out by a qualied
electrician.
• A person is regarded as a qualied electrician, if, due to his/her vocational education, knowledge and
experience, he or she is capable of and authorized to judge and carry out the work commissioned
to him/her. This also includes the recognition of possible dangers and the adherence to the pertinent
regional and national standards, rules and regulations.
• For your own safety, please consult a qualied electrician.
• The unit may only be connected when the electrical data of the unit and the power supply coincide.
The unit data is to be found on the unit type plate or on the packaging, or in this manual.
• Ensure that the unit is fused for a rated fault current of max. 3A on the mains side by means of a fault
current protection device.
SAFETY INSTRUCTIONS

(C) 2021 Syncronorm GmbH
6
SAFETY INSTRUCTIONS
Save Operation
• Never operate the unit, if either the electrical cables or the housing are defective!
• Do not carry or pull the unit by its electrical cables.
• Route cords/hoses/lines in a way that they are protected against damage, and ensure that they do
not present a tripping obstacle.
• Only open the unit housing or its attendant components, when this is explicitly required in the ope-
rating instructions or approved/prescribed by Syncronorm‘s technical support service.
• Only execute work on the unit that is described in this manual. If problems cannot be overcome,
please contact an authorized customer service point or, when in doubt, the manufacturer.
• Only use original spare parts and accessories for the unit.
• Never carry out technical modications to the unit.
• Only operate the unit, if no persons are in the water!
• The unit, the connections and the plugs are not water-proof and must not be routed or installed in
water.
Qualications and Training of Employees
• Ensure that installation personnel have the required technical qualications.
• Also ensure that all operating personnel are suciently qualied.
• Ensure that maintenance work is only performed by personnel authorized for this purpose, e.g.
specialists of Syncronorm GmbH or personnel with suitable training.
Dangers resulting from non-adherence to the Safety Information
Please note that Syncronorm GmbH assumes no liability for damage, downtimes or malfunctions resul-
ting from non-adherence to this installation and operating manual. By ignoring or not adhering to all of
the safety information contained in this manual, you could endanger people, the environment and the
system of this unit. For example, non-adherence to the safety information contained in this manual can
lead to the following dangerous occurrences:
• A malfunction of important features of this unit
• Danger for persons due to electric shock
Safety-conscious Operation
As a user of this unit, ensure that you follow all safety information contained in this manual. Follow the
accident prevention regulations at all times. If the unit is used in a location where internal regulations,
operating and safety instructions apply, ensure that these regulations and instructions are also adhered
to.

(C) 2021 Syncronorm GmbH 7
Optional retrotting and Production of Spare Parts
Safety Information regarding Maintenance, Inspection and Installation Work
Changes or modications to the device are only permitted after consultation with the manufacturer.
Original spare parts and accessories approved by the manufacturer provide safety. We wish to stress that
all parts and accessories not supplied by Syncronorm GmbH have neither been tested nor approved
by Syncronorm GmbH. For this reason, the installation and/or use of such products can, under certain
circumstances, negatively aect the specications for the device. This could also lead to restrictions of the
active and/or passive safety of the device. Syncronorm GmbH assumes no liability for damage resulting
from the use of parts and accessories other than original Syncronorm GmbH parts.
In this case all guarantee expires.
It is the owner/user‘s responsibility to ensure that all maintenance, inspection and installation work is car-
ried out by authorized and qualied personnel, who have read and understood this manual.
Only carry out maintenance work on this unit, when the unit system is switched o. Ensure that no
pressure is applied to the unit and it is disconnected from the power supply (voltage-free) before carry-
ing out maintenance or repair work.
Ensure that small malfunctions are immediately rectied by authorized personnel to avoid possible future
damage, malfunctions and/or downtimes of the unit system. Certain maintenance work may require
safety barriers to be removed and/or deactivated. If this is the case, ensure that all safety and protective
devices/guards are re-installed and/or reactivated after completing the maintenance work.
Dangers encountered by the Combination of Water and Electricity
• The combination of water and electricity can lead to death or severe injuries from electrocution, if the
unit is incorrectly connected or misused.
• Prior to reaching into the water, always switch o the mains voltage to all units used in the water.
SAFETY INSTRUCTIONS

(C) 2021 Syncronorm GmbH
8
CONNECTION
Connectors
The DAC Decoder 4x comprises of these connectors::
CN6 POWER SUPPLY 230V AC 50 Hz
1 black: L 230V AC
2 blue: N 0V AC
CN2 DMX Data Input
1 (grey) GND, Screen
2 (blue) DMX Drive Signal -
3 (orange) DMX Drive Signal +
CN3-6 Drive Output to electronic ballasts
1 CH 1: Drive Signal 1
2 CH 1: Drive Signal GND
3 CH 2: Drive Signal 2
4 CH 2: Drive Signal GND
5 CH 3: Drive Signal 3
6 CH 3: Drive Signal GND
7 CH 4: Drive Signal 3
8 CH 4: Drive Signal GND
Refer to the drawing for the location of the connectors. To open clamp, press lever. Insert wire, release
lever.
You may connect DSI (Digital Serial Interface) compatible, or DALI (Digital Addressable Lighting Inter-
face) compatible, or analog 1-10V compatible electronic ballasts (EVG) to the DAC Decoder 4x. Optimum
performance will be obtained when using DSI compatible ballasts. The interface has to be programmed
for Analog, DSI or DALI mode, see below. You are not allowed to mix analog, DSI and DALI devices on
one decoder. Ballasts must be connected to the output terminals of the DAC Decoder 4x. Multiple bal-
lasts may be connected in parallel if required – see technical data. Digital SYNCRONORM PCA electronic
ballasts are insensitive to polarization. If using other ballasts, please check before wiring. The signal out-
put of the DAC Decoder 4x is positive (+).

(C) 2021 Syncronorm GmbH 9
CONNECTION
Signal Indicators
Status signalling is with LED indicators:
- green: DMX data reception OK
- red: ERROR
- normally o
- blinks at transmission errors or at loss of signal
DMX Start Address
It is a commonly used scheme for building automation devices to avoid conguration switches. All
settings are stored permanently in non-volatile memory. When installing the decoder for the rst time,
however, the output protocol and the DMX start address (number of the rst DMX data slot, value 001 ...
509) must be programmed. The start address switch board 3000P or 3003P is required to set start ad-
dress and mode of operation. This is a standard device, which can be used for all Syncronorm decoders.
DMX-IN 24V DC POWER
START-ADR
MODULE
4x ANALOG 0..10V OUTPUT

(C) 2021 Syncronorm GmbH
10
SETTINGS & SETUP
Programming adaptor
To set a DMX start address, connect the address board as decribed above. Make sure the connector is
plugged in the right orientation as indicated on the label. Connecting the address board the wrong way
may damage both, the decoder and the adress board. Then power up the decoder and apply a valid
DMX signal. Then simply set the desired start address. The hundreds switch is located next to the LEDs.
Valid address settings are from 001 to 509. Wait some seconds until the unit recognizes and programs the
address setting. The programming cycle will be indicated by the the red and green LED ashing alterna-
tively four times. If the decoder is already fully wired you may test the system for proper operation right
now. If everything works to your satisfaction, power down the system and remove the address board.
DIP switches
The output protocol of the decoder and the behaviour at loss of data may be selected by the user. The
address board consists of four DIP switches to select the required features. All settings are stored in inter-
nal nonvolatile memory (same as the DMX start address).
DIP-SWITCH 1: DMX HOLD
Denes the behaviour at loss of DMX data.
OFF= see DIP switch #2
ON = DMX HOLD at data loss
Connector for start address board and polarization notice Hundreds - Tens – Ones
DIP-SWITCH 2: OUTPUT LEVEL AT NON-HOLD
OFF= all outputs are driven to 0% (e.g. stage lighting)
ON = all outputs are driven to 100% (e.g. architectural lighting)
DIP-SWITCH 3/4: OPERATING MODE
OFF/OFF= Analog output 0..10V / 1-10V
ON /OFF= DSI
OFF/ON = DALI
ON /ON = PWM