SYNCOLN 13100 Manuel utilisateur

SYNCOLN 13100

COMPACT SYSTEM
GAS DETECTOR & SOLENOID VALVE

3
CONTENT;
1 About the Device: ..……..….……………………………………………..……………………... 4
1.1.1 Maintenance : …………………………………………………………………………………….. 4
1.1.2 Assembly: ….…….…………………………………………………………………….……...… 4/5
1.1.3 Gas Detector and Connecting to output elements: ……………………………………...... 5
1.1.4 Gas Detector and Connecting to Solenoid Valve: ……………...………………………... 5/6
1.1.5 Connection Table and Alerts: …...…………………………………….……………………… 6
1.1.6 Instruction: …………………………………….…………………………..…….……………….7
1.1.7 Gas Detector Technical Specifications: ……………………………..………….……...……8
1.1.8 Solenoid Valve Technical Specifications: ……………………………….…….….…………9
1.1.9 Gaz Detector’s with 2 cable output installation to a Solenoid Valve: ……….……….. 10
1.1.10 Warranty Conditions: ……………………………..…………………………………………. 11
1.1.11 Qualified Service: ……………………………………………………………………………...12

COMPACT SYSTEM
GAS DETECTOR & SOLENOID VALVE
1. About Device
NYS in weather that can detect explosive gases (natural gas and LPG) is a device. This type of dangerous gases
are detected, the gas detector NYS buzzer (tone) and audio, with LED allows the light warning.
The green LED lights, and stand-alone device, as long as electricity is fed to the burning of a dangerous situation
as long as there is no middle. NYS of explosive gases (natural gas and LPG) in the case of one found in red LED
lights. At the same time buzzer (tone) the yellow led on the circuit is enters. Device error (failure) led indicates.
Yellow loss of continuity and short circuits in case the sensor is engaged.
Every time you plug the device is inserted and the maximum period of 45 seconds, the need for a calibration plug
is inserted hear this from the moment the device 45 seconds after the gas detection device that can position also
passes this feature in case of power failure to close solenoid valve in obstacles.
NYS methane gas detectors (CH4), propane (C3H8) and butane (C4H10) gas, the figure is well below
dangerous even detects and boiler, furnace, catalytic heater, gas water heater, such as working with explosive
devices in places where you truly provide security.
1.1 Maintenance: A damp cloth to clean the device, light can have.
1.1.2 Assembly: NYS gas detectors, explosive gas (LPG and natural gas) is used where (boiler, water heater,
cooker, oven, etc.) at a maximum distance of 1 meter should be mounted in a fixed location. Mounting screw
holes on the back of the NYS gas detector can benefit from.
While the device installed may affect device reliability emerged as a common material for steam and gases
(cleaning fluids, nail polish, paints, cooking processes perfume and deodorant) will not be affected should be
mounted in a location.

5
Voltage of 220 VAC with standard city after mounting NYS gas detector chips are ready to work by attaching.
NYS 'will be mounted on the need to consider are the issues. These points can be specified as follows:
In LPG (tubes) are used, the device must be mounted near the place, and from the height should not exceed 30
cm and absolutely. LPG is heavier because of the air.
If you are using the natural environment, the device must be mounted to the ceiling and then the ceiling should
not exceed 30 cm distance from. This is because the natural gas is lighter air. Should be considered in these
matters is understood more clearly in Figure 1.
1.1.3 Linking to Exit Elements of Gas Detectors; As elements of the output solenoid detector NYS gas
valve and / or can be connected to the horn. These links, NYS are provided with gas detectors to the ignition
cable.
1.1.4 NYS 'Linking e Solenoid Valves: Solenoid valves, gas lines, and feeds on the fly when the
voltage is cut off gas. Solenoid a valve, NYS gas can be controlled by the detector. NYS solenoid valve

COMPACT SYSTEM
GAS DETECTOR & SOLENOID VALVE
connected to a dangerous situation if the valve is engaged in NYS ' in addition solenoid and gas transmission cut
off. This mechanism gives you a security effortless and flawless.
To connect the gas valve solenoid valve to NYS detector Figure 2, follow these instructions to the benefit.
The first phase of the network flow (R) end of the BLACK cable to connect the output cable NYS ' in contact.
After making a connection to the BLACK wire cable output end NYS 'in RED 220V nutrition solenoid valve end of
any one of with terminal connect.
One from the other end of the feed valve Selenoid terminal neutral network (MP) to connect the ends.
Leave blank the BLUE cable NYS gas detector.
Of gas detectors to 220VAC outlet cord NYS connect cable.
After making all these connections are available solenoid valve.
!
1.1.5
A person must be installed by DEVICES
PAPERS.
For any questions about your device and
problems by phone, fax numbers and e-mail
address we can reach our technical service.

7
1.1.6 After the device needs to be done to give the alarm;
All weather materials, including all the naked flame should be extinguished.
All gas appliances should be shut down.
Gas detectors, including the not open any electrical equipment and should not be closed.
Gas supply from the main gas control and / or (if LPG source) from the storage tanks should
be closed.
To increase the ventilation doors and windows should be opened.
Buildings are suspected to have the gas should not be used in the phone.
Once installed, the alarm will continue to give back the device and the leakage is not
understood because the company immediately to provide gas or 24-hour emergency gas
service must be reported.

COMPACT SYSTEM
GAS DETECTOR & SOLENOID VALVE
1.1.7 TECNICAL SPECIFICATIONS / GAS DEDEKTÖR ;
NYS
Power Consumption:
3W (maximum)
Power Source:
220V +%10 (50-60 Hz)
Buzzer
85 dB (minimum)
Selenoid Valve Outlet:
250 VA (maximum)
SENSOR
Sensor:
OEM
Warm up Period:
45 seconds
Sensor Measurement/
Detection Range:
EN 50194
(European Standard)
Life of the Sensor:
5 years
ENVIRONMENT
Temperature:
0
o
C – 50
o
C
Humidity:
%80 (maximum)

9
1.1.8 SOLENOİD VALVE / MANUAL RESET VALVES
Technical Specifications;
•Threaded Mounting : DN15, DN20, DN25
•Max. İnlet Pressure : 500 mbar
•Working Voltage : 230 V AC/50 Hz -12 V DC/ 18W -24V
•Working Temperature: -15 °C / 60 °C
•Tensile Strength : Materials’ tensile strength referred to TS-519 ,EN 161 standards.
•Material Type : Body and cover are Entail 140 aluminum brass forgings. Resetting shaft and knob are
MS 58 DIN 17660 brass.
•Fluid Types : Suitable for natural gas (group-CH4 ) liquid petroleum gas,propane, air ( %79 nitrogen,
% 20.1 oxygen) and other non-corrosive gases;
by any means of domestic and industrial use.
Installation ;
.Before installing the valve, carefully check the flowing direction shown by the arrow onthe valve itself •
.These valves can beinstalled either vertical orhorizontal •
. Be sure that the piping is clean and aligned •
. Do not exceed limits (pressure,temperature etc.) defined inthe technical specifications •
. Reset by pulling the knob vertically after installing the valve •
; Maintenance
These valves do not require maintenance •
In case of any trouble occours during installation orresetting the valve please contact the manufacturer. Never •
. try to disassemble
. The valve and connected pipes should notcarry heavy loads •
Once every 6 months, do the lighter test using the Gas Detector •

COMPACT SYSTEM
GAS DETECTOR & SOLENOID VALVE
Power:Join Blue cable together and then connect it to – neutral source
Power: Join Brown cable together and then connect it to + source
1.1.9 Gas Detector’s with
2 cable output installation
to a Solenoid Valve:
•POWER Connection: First join
brown cables together and then
blue cable together. On the
brown cable connect it to
positive source and the blue
cable to neutral soruce.
•Relay Switch Connection:
Connect red to red cable and
then black to black cable.
•Then connect the red and black
cables to a selnoid valves. Note;
it does not matter which cable
goes to which end as long as
colors stay the same.
Autres manuels pour 13100
1
Table des matières
Manuels Détecteur de gaz populaires d'autres marques

Macurco
Macurco GD-6 Manuel utilisateur

Evikon
Evikon E2632 Manuel utilisateur

Critical Environment Technologies
Critical Environment Technologies CGAS-A Series Manuel utilisateur

MSA
MSA altair 5 Manuel utilisateur

DOD Technologies
DOD Technologies ChemLogic CL96 Manuel utilisateur

DEGA
DEGA NS III LCD Series Manuel utilisateur