1. AbouttheWeldingGuide
Theweldingproceduredescribedin thisguideisusedforweldingflange in tovessels.The
guidelinesreferonlytothetechnicalaspectsofweldingoperations.Pleasenotethatalldatawith
regardtoweldingcurrent,timeetcareapproximateand mayvaryin practice.Referencesaremade
totheSwedishcodeforpressurevessels,TKN87. Ensurethattherelevantstandardsforpressure
vesselsarecomplied withthevessel.
RoplanABs liabilityforpossiblefaultsareregulatedbyECE 188. ThisimpliesthatRoplanABis
responsibleforfaultspresentin theproductatthetimeofdelivery.
RoplanABisnotresponsibleforfaultsthatoccurduetoconditionsthatariseafterdelivery,for
examplefaultyhandling,weldingorfitting.
Asastepin RoplanABs qualityassurance,eachflange isinspectedpriortodeliverytoensure
conformance withregardtosize and otherrequirementsoftheRoplanABs drawings.Acertificate
isenclosed with each delivery.
Thisprocedureensuresthattheprobabilityofan original faultisverysmall. Faultsthatdooccurcan
normallybetraced to incorrecthandling, weldingorfitting.
RoplanABs experience isthatthegreatestriskofafaultoccurringisdeformation in connection
with weldingtheflange into thegableend ofthevessel.
Tominimisetheriskoffaultsoccurringafterdeliveryfrom RoplanABitisessentialthatthis
weldingguideisstudiedand thatonlyproperlytrainedand experiencedpersonnelareemployedin
theweldingoperations.
Forothercountriesthan Sweden, pleasemakesurethattherelevantstandardsforthatcountryare
complied with.
Thepurposeofthismanual isto avoid deformation oftheSteriflange dueto releaseoftension
forcesin thegable.
Thismanual should onlyberegarded asan aid in theweldingwork and notoverridethelegal
obligations.