4. INSTALLATION
3. POWER SUPPLY CONNECTION
(1) This Steak locker requires a standard 115VAC, 60HZ or (220 VAC, 50HZ) electrical outlet.
(2)Standard socket with earth connection (12~16A,115V~)
(3)The appliance should always be plugged into its own individual electrical outlet which has a voltage rating that
matches the rating label on the appliance. IT IS HIGHLY RECOMMENDED THAT A SURGE PROTECTOR
BE INSTALLED BETWEEN THE OUTLET AND THE SL UNIT.
This provides the best performance and also prevent overloading house wiring circuit that could cause a fire
hazard from overheated. Never unplug the appliance by pulling the power the power cord. Always grip the
plug firmly and pull straight out from the receptacle. Repair or replace immediately all power cords that have
become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its
length or at either end. When moving the appliance, be careful not to damage the power cord.
(4) Plug in the Smart App Controller into the cable provided
inside the SL Unit.
(1)Make sure when you unpack it there is no defect in its external appearance when you receive your
Steaklocker.
(2) Open the door and check to see that the inside is complete (walls, shelves, hinges, Control panel, etc.)
(3)Place your Steak Locker in its operating location after going through the previous steps checking. Ensure the
the following requirements below:
A. Allow at least 50 mm between the back and sides of the Steak Locker; and leave a minimum space of
50 mm between the back cabinet and the wall.
B. Place your Steak Locker on a floor that is strong enough to support it when it is fully loaded. Adjust the four
adjustable legs to ensure proper leveling of your Steak Locker.
(4)Locate your Steak Locker away from direct sunlight and sources of heat and high humidity areas, such as
hot garages, patios, laundry room and bathroom, etc.
(5)Do not tilt the Steaklocker at an angle of more than 45° when moving it. Allow a minimum 10 minutes
interval between transit and re-starting.
(6)PleaseensureplentyofnaturalventilationaroundyourSteakLocker, otherwise, it will reduce the
effect of usage.
(7) Water Reservoir:
Prior to Powering On SL Unit;
- add DISTILLED water to the reservoir
drawer at least to the Minimum Line.
- avoid opening the drawer past the
orange filter (approximately 4 inches)
- remove plastic from filter prior to use.
When low on water, an audible alarm
will sound and the code E6 will
display in the digital window.
Add more water at that time.