R280
Bluetooth Laser Receiver
Instruction Manual
Another fine solution by

2Status Pro – R280 Instruction Manual
R280
Instruction Manual – English
Laser Receiver R280
(BG 831500)
Software version V 1.00
We woul like to congratulate you on the purchase of your Status Pro R310 Laser receiver.
Before initial usage you shoul carefully rea the safety instructions as well as the user
gui elines containe in this manual. We wish you every success when using this
Measurement Instrument.
Please note: User Manuals can be amen e when improvements or changes to the pro-
uct range have been carrie out. Use the link below to make sure you have the most up
to ate version of your User Manual: www.statuspro.com.

Status Pro – R280 Instruction Manual 3
CONTENT
Content
1. SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Class of Laser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Stan ar s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3 A vice on batteries / rechargeable cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.4 Instrument care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.5 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.6 Calibration an repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.7 Liability exclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2. GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3. HANDLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.1 Button Panel of the R280 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.2 LED Signals from the R280 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.3 R280 Monitor Control Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4. MEASUREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.1 Setting up a laser plane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.2 Checking an calibrating the T330 Self-Levelling function . . . . . . . . . . . . . . . . . . . . 12
. TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6. ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7. PRODUCTS AND SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8. MEMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1. Safety Instructions
1.1 Class o Laser
The laser light emitte from a Status Pro Laser has an Output Rating of < 1,0 mW.
The Laser is place in the category „Class 2“ an is classifie as safe for the use as
a measurement instrument. There are however a few safety aspects to be observe :

1.2 Standards
All Status Pro Laser an Receiver Instruments are evelope an manufacture
accor ing to the following CE Stan ar s:
•EN 55 011
•EN 55 022
•EN 61 000-4-2
•EN 61 000-4-3
•EN 60 335
1.3 Advice on batteries / rechargeable cells
If the equipment is being store for a longer perio of time or being powere using Mains,
then the batteries shoul be remove to prevent amage of the instrument through
leakage.
4Status Pro – R280 Instruction Manual
SAFET INSTRUCTIONS
R280
Caution!
•Do not stare into the laser beam.
•Do not point the laser beam at other people.
•Observe the local safety gui elines on Site an if in oubt consult
the Site safety Engineer.
•Do not use the equipment in amp or moist locations.
•Ensure sha ing of the equipment against irect sunlight or heat
sources.
•Flui s or rain as well as extreme temperature con itions may
amage the equipment.
Note
Do not violently shake the Laser or other sensors an always
protect against falls. This can amage the structure or the optics
of the instrument resulting in false measurements.
Do not touch rotating parts when in use!

When using rechargeable cells always observe the specific charging proce ures for the
cells.
Rechargeable cells can be recharge aroun 1000times when treate correctly, but there
is no guarantee!
1.4 Instrument care
Your measurement instrument is esigne for use in an in ustrial environment an can
withstan water splashes or light spray as well as ust. Clean the equipment using a soft
cotton cloth an a mil soap solution. Laser apertures as well as well as sensor areas
shoul only be cleane using a soft, ry an ust-free cloth. Do not use paper towels to
clean glass surfaces as they coul scratch. Avoi contact with grease, oil or oil-base
solutions when han ling the equipment.
1.5 Maintenance
The mechanical components of your equipment are prone to natural wear an tear! If the
Instrument appears to have a technical efect, contact the Manufacturer. Do not try to
Status Pro – R280 Instruction Manual
SAFET INSTRUCTIONS
Caution!
Do not try to recharge normal batteries. Do not expose batteries
or rechargeable cells to fire or excess heat (Danger of explosion).
Do not mix batteries an rechargeable cells.
Always use batteries an cells of the same kin .
Do not mix ol an new batteries or cells.
Note
Help to protect the environment! Empty batteries o not belong in
the househol waste isposal system. Only eposit empty or
amage cells at a collection point specially esigne for this
purpose.

6Status Pro – R280 Instruction Manual
SAFET INSTRUCTIONS
R280
repair or open the sensor casing. Attempte repairs through unauthorise personnel
makes the guarantee null an voi ! Always store the equipment un er ry con itions an
use the case for transportation.
To ensure trouble-free processing, simply fill in the form you will fin using the following
link: www.statuspro.com/machine_geometry/service_support/calibration_repair
1.5 Calibration and repair
To guarantee measurement accuracy, an reliable operation of your Status Pro
Measurement System, it is of utmost importance that the recommen e Service Intervals
be a here to. The System shoul be checke for serviceability, an re-calibrate by the
Status Pro workshops every 12 months.
Within the scope of the service checks, the complete system will also be examine for
possible wear or amage, as well as receiving any software up ates. The ate of the next
service check for your equipment is stampe on the Status Pro calibration sticker.
To ensure trouble-free processing of the service an calibration checks, simply fill in the
form you will fin using the following link
www.statuspro.com/machine_geometry/service_support/calibration_repair.
1.6 Liability Exclusion
The Status Pro GmbH oes not accept responsibility for amage incurre through incor-
rect use or han ling of the equipment. To ensure correct usage, a foun e knowle ge of
the equipment is essential. It is of the utmost importance that you rea an un erstan
the Han book!
No responsibility will be accepte for amage incurre through ignorance or isregar ing
of the operating instructions.
Advice
To be able to i entify the equipment when seeking a vice always
quote the serial number of the equipment. The Manufacturer oes
not accept any responsibility for amage incurre through incorrect
maintenance carrie out by non-authorise personnel.

2. Getting started
2.1 Power Supply
The R280 can only be powere using a Type BT 800071 re-chargeable cell. A completely
charge cell will provi e enough energy for aroun 8 hours usage. A ischarge cell can
be recharge in approximately 1,5 hours using the external charger (BT 800072) . Constant
operation is possible if a secon cell is available (optional extra).
The battery pack (III) can be accesse by opening the rear cover (I) . To open the cover,
simply pull, using the two in entations(II), the cover is hel in place with a magnet.
The battery is place in the housing with the contacts
pointing to the mi le of the sensor. The battery is place
correctly when the rear cover closes without any resi-
stance. Due to the shape of the housing it is normally
possible to fit the cell incorrectly.
Status Pro – R280 Instruction Manual 7
GETTING STARTED
I
II
III
IV

2.2 Assembly
The R280 Laser receiver has two M8 threa s (V) on the un ersi e an two on the top si e.
The threa s enable correct fitting of the Magnet A apter Typ BG 831510, usually use
when measuring objects. The A apter consists of a switcheable magnet (VII) an a revol-
veable column (VIII). The a apter can be fitte at either en of the sensor.
8Status Pro – R280 Instruction Manual
GETTING STARTED
R280
Please ollow instructions below:
➜Cell fitte correctly (Contacts eepest position in the housing)
➜For use solely with cell type: BT 800071
➜Remove cell before prolonge storage (Danger of corrosion)
V
VI
VIII
IX
VII
A apter BG 831510

When fitting the A apter to the un ersi e of the sensor, the locating owel (IX) an the
rilling (VI) ensure correct positioning of the sensor . When fitting the A apter to the
above si e, the locating owel has to be remove (M3 Allen Screw).
The BG 831510 A apter facilitates rotation of the sensor in the Axis an is play-free, enab-
ling accurate measurements.
Alternatively, the A apter BG 831550 (X) can be mounte to the sensor enabling use of the
M8 measuring a apter (BT 948336) (XI). The measuring a apter (XI) is fitte into the recess
in the A apter (X) an secure with the knurle screw (XIII). The asymmetrical groove on
the M8 A apter guarantees a constant an repeatable fitting of the sensor an thus, sen-
sor height.
The measurement a apter (XI) with its 8mm threa (XII) on the un ersi e can be fitte to
the larger switcheable magnet (BT 943092) or irectly screwe into existing or purpose
cut threa s on machine or other objects. The permanent fitting of the a apter allows peri-
o ic or constant measurements on machines or buil ings for example, whereby the sen-
sor oes not have to stay in place if perio ic an not constant measuring is require .
To rotate the R280 in the laser axis when using the BG 831550 (X) A apter, simply loosen
the knurle screw (XIII), rotate as wishe an then re-tighten the knurle screw.
Remember, the R280 shoul always face the T330 in an orthogonal fashion.
Status Pro – R280 Instruction Manual 9
GETTING STARTED
A apter
BG 831550
A apter complete with
M8 A apter mounte on
the switcheable
Magnet BT 943092
M8 A apter
BT 948336
X
XI
XII
XIII

3. Handling
3.1 Button Panel o the R280
To turn on the R280 simply press the On/Off button, to turn Off press an hol for 1 secon
or longer. The rotating beam of the laser sweeps across the etector area(E) an a value
is elivere to the Display Unit over BlueTooth. When BlueTooth communication is active,
the BT LED (B) will flash intermittently (BlueLED). The postion of the laser beam in respect
to the centre or Zero position of the etection area (E) is signifie over the two irection
LED´s (F&H). When the Measurement Trigger button (I) is presse , the sensor measures
the values over the pre-set perio entere in the software, then recor e . During measu-
rement the sensor shoul not be move or isturbe . The Battery LED (D) shows the
power capacity available.
10 Status Pro – R280 Instruction Manual
HANDLING
R280
A
BF
CG
D
E
H
I
AOn / Off Button
BBluetooth LED
CInfra-re aperture
DBattery an Sensor status LED
EDetection area
FLaser position LED above centre
GOK LED
HLaser position LED below centre
IMeasurement triggering button
Table des matières