TECH TIP
MC521 PRO CONTROLLER
SLIDE DOOR
Installation and Operation Manual
Prepared by: Jeff Bonas Engineer: Tony Ranaudo, Len Pursell Tech Tip: TT170727
CN: _________ RDW: ________ Reference Tech Tip: ________
Engineering Document Number: ________
Summary Information
Product Information
Bifold Swing Accessories Operators / Drives Sensors
Slide Class 2 Controls Panels / Hardware
Tech Tip Classification
Adjustment Customer Complaints FAQs Retrofit/Upgrade Instructions
Installation Clarifications Service Design Change Description
Release Action
Level 1 - Does not impact maintenance or operation of door. (Only Safety/Liability and Engineering need to sign.)
Level 2 - Full sign off required.
Release Information (initial and date)
Safety/Liability _________________________
Engineering _________________________
Technical Support _________________________
Field Operations _________________________
Quality _________________________

If you have any questions concerning this procedure, contact
Access Technologies Technical Support, at 1-800-422-6489 Option 3.
Page 1 of 1 Tech Tip: TT170727
MC521 PRO CONTROLLER
SLIDE DOOR
Installation and Operation Manual
Attached is the revised MC521 Pro Controller Manual:
MC521 Pro Controller Installation and Operation Manual (204066)
Rev. F, for automatic sliding doors)
Included in the revised manuals are the following:
Settings for Monitored Presence Sensors
Updated Wiring Diagrams including monitored presence sensors
Android MC521 Toolbox Troubleshooting enhancements for monitored
presence sensors
Android MC521 Toolbox Troubleshooting Output Control Mode

Stanley Part Number 204066
REV F 12.2016
Copyright 2016, Stanley Access Technologies, LLC.
Prohibition on Copying: Any unauthorized reproduction, disclosure or distribution of copies by
any person of any portion of this work may be a violation of copyright law of the United States
of America and other countries, could result in the awarding of statutory damages of up to
$250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties.
All rights reserved.
MC521 Pro Controller
Installation and Operation Manual
204066
INCLUDES INSTRUCTIONS FOR
DURA-GLIDE™ 2000/3000, 5200/5300,
DURA-GUARD™ DURA-STORM™ AND DURA-MAX™ 5400-SERIES
AUTOMATIC SLIDE DOOR SYSTEMS

GENERAL DESCRIPTION
Intended Use
This manual provides installaon instrucons, wiring instrucons, and tune-in instrucons for the MC521 Pro
Controller. It includes instrucons for Dura-Glide™ 2000/3000, 5200/5300, Dura-Guard™, Dura-Storm™, and Dura-
Max™ 5400-Series, Automac Slide door systems.
On Dura-Glide sliding doors, the MC521 Pro Controller replaces the MC521 or both the microprocessor control
box and the interface board on older models. The door acvaon devices (SU-100 moon sensors, carpets, push
plates, etc.), lock, funcon switch, doorway holding beams, and door posion switches previously connected to the
interface board must be connected to the MC521 Pro Controller.
Aachment 1 illustrates the MC521 Pro Controller controls and indicators. Aachment 2 illustrates system wiring
for Dura-Glide series sliders.
Applicability
This manual is applicable to the Dura-Glide series sliding doors used on Dura-Glide™ 2000/3000, 5200/5300,
Dura-Guard™, Dura-Storm™, and Dura-Max™ 5400-Series, Automac Slide door systems. Instrucons for
connecng oponal accessories are not provided in this manual.
Table of Contents
General Description ........................................................................................................... 2
Intended Use.............................................................................................................................................2
Applicability ...............................................................................................................................................2
Prerequisites..............................................................................................................................................3
Precautions ................................................................................................................................................3
Installation Instructions .................................................................................................... 3
Installing the MC521 Pro Controller ............................................................................................... 3
Wiring Instructions ............................................................................................................ 3
Evaluating Power Requirements........................................................................................................ 3
Connecting Main Power Wiring ........................................................................................................ 4
Connecting Accessories (As Applicable)......................................................................................... 4
Tune-In Instructions........................................................................................................... 4
Tuning In the MC521 Pro Controller Using a Handheld Device ........................................... 5
Tuning In the MC521 Pro Controller Using Pushbuttons ....................................................... 9
Final Tune-In Adjustments ................................................................................................................13
Spare Parts List ................................................................................................................. 14
Attachments ..................................................................................................................... 15
Attachment 1 - MC521 Pro Controls and Indicators...............................................................15
Attachment 2 - MC521 Pro System Wiring Diagram .............................................................17
Attachment 3 - MC521 Pro Terminal Block Connections TB1-TB7 ...................................28
Attachment 4 - ANSI/BHMA and UL Compliance Requirements for Sliding Doors ..29
Attachment 5 - Handheld Device Troubleshooting Aid ........................................................31
Attachment 6 - Handheld Device Troubleshooting Screen Descriptions .......................32
Attachment 7 - MC521 Pro Troubleshooting Aid ....................................................................34
Attachment 8 - Recommended Values for Dierent/Weights Types of Slide Door....35
Attachment 9 - Fine Tuning Slide Doors .....................................................................................36
1
Copyright 2016, Stanley Access Technologies, LLC.
All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
12.28.2016
2 Document # 204066 REV F • www.stanleyaccess • 1.800.7.ACCESS

MC521 PRO Control Box
12.28.2016
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204066 REV F 3
Copyright 2016, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
Prerequisites
Special Items Required:
• Stanley Access Technologies document No. 203957, “SU-100 Moon Sensor Installaon and Operaon” (if
installed).
• SU-100 tune-in remote control (if SU-100 Moon Sensor is installed).
• Stanley Access Technologies document No. 203768, “StanguardTM Threshold Sensor Installaon and Operaon”
(if installed).
• Optex X Zone T or X Zone ST manufacturer’s installaon and tune-in instrucons (if installed).
• Hotron HR100 ST manufacturer’s installaon and tune-in instrucons (if installed).
• For a list of compable handheld devices; visit: hp://www.stanleyaccess.com
Select Door Service > Technician Mobile Downloads > Android Apps. Select Compable Handheld Devices Document.
• Bluetooth adapter or cable to connect compable handheld device to MC521 Pro Controller.
• Degreaser.
• Instrucons for any other device to be wired into the MC521 Pro Controller.
Precautions
All ANSI/BHMA and UL Requirements in Attachment 4 must be met before the door is put into operation.
INSTALLATION INSTRUCTIONS
Installing the MC521 Pro Controller
NOTE: This manual covers new door installaons in which the MC521 Pro is factory-installed and wired.
WIRING INSTRUCTIONS
Evaluating Power Requirements
• ENSURE power source is a dedicated 115 VAC, 50/60 Hz source with 20A circuit rang. If four operators are
used, the source should have a 30A rang.
• ENSURE no more than four operators will be connected to one circuit.
• ENSURE power source is not shared with other equipment, i.e., cash registers, EAS systems, or other electro-
magnec interference generators.
2
3

MC521 PRO Control Box
4 Document # 204066 REV F • www.stanleyaccess.com • 1.800.7.ACCESS
Copyright 2016, Stanley Access Technologies, LLC.
All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
12.28.2016
Connecting Main Power Wiring
Warning: To prevent injury to personnel, incoming electrical power to the header must be deenergized before
connecng electrical service to the control box.
Warning: All electrical wiring must conform to Naonal Electrical Code Requirements.
1. DEENERGIZE incoming electrical power to header.
2. Refer to Aachment 2, and, using wire nuts, CONNECT incoming line, neutral, and ground wires
to the controller power harness.
3. IF adhesive wire clamps will be used, DEGREASE metal surfaces on inside of header cover
where clamps will mount.
4. SECURE wiring to top of the header track tube, and ENSURE the following:
• All wires are clear of belts and belt brackets.
• Header cover opens and closes without interference.
Connecting Accessories (As Applicable)
Refer to Aachments 2 and 3, and CONNECT any of the following subsystems to the MC521 Pro Controller:
• Funcon switch (rotary, rocker and “POWER” switch wiring).
• StanguardTM threshold sensor.
• Doorway holding beam(s).
• Breakout switch.
• Solenoid lock.
• SU-100 moon sensor(s) wiring (refer to Stanley Document #203957).
• Optex X Zone T and X Zone ST Sensor(s) wiring.
• Push plate wiring.
• Door posion switch closed contact (with door closed).
• Hotron HR100 ST Sensor(s) wiring.
TUNE-IN INSTRUCTIONS
Warning: The door path must be free of objects and remain clear unl the First Install Sequence (FIS) is
complete. During this sequence the sensors are inacve and the door has no SAFETY. To stop the door, turn
power off or put the doors into breakout.
NOTE:
1. Tune In: The MC521 Pro Controller can be tuned-in using a handheld device or using the pushbuon
switches located on the controller. Tune-in using a handheld device is the preferred method.
2. Status Codes: During normal operaon, the digital display indicates status codes. The “UP” and “DOWN”
pushbuon switches can be used to enter and display data values. The user interface values are shown in
Tables 2 through 4.
4

MC521 PRO Control Box
12.28.2016
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204066 REV F 5
Copyright 2016, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
3. Solenoid Lock: If a solenoid lock is installed with no lock circuit board (new style), set Lock Logic to the actual
lock type (Fail Safe or Fail Secure). If a Fail Safe or Fail Secure Lock is being installed with a lock circuit board
(old style), the Lock Logic must be set to Fail Secure.
4. Handing: Manually open door nong rotaon of belt pulleys. If counter clockwise (CCW) use right hand during
FIS. If clockwise (CW) use le hand during FIS. See gure below.
5. FIS: The rst installaon sequence (FIS) is used to perform the inial conguraon. Upon compleon of FIS,
all setup parameters are stored in non-volale memory. Subsequent power cycles will reload the congura-
on parameters that were congured during FIS.
6. Decimal points on digital display are encoder 1 signals.
7. Aer changing values, the values must be saved in EEPROM by cycling the door to full open.
PULLEY ROTATES CCW
WHILE OPENING
USE RIGHT HAND IN FIS
PULLEY ROTATES CW
WHILE OPENING
USE LEFT HAND IN FIS
RIGHT HAND
LEFT HAND
HANDING
Tuning In the MC521 Pro Controller Using a Handheld Device
NOTE: The following steps provide instrucons for tuning the MC521 Pro Controller using a handheld device.
MC521 applicaon soware is required. Connect the handheld device to the MC521 Pro Controller, turn on header
POWER switch, and perform the following steps.
Step 1: Select MC521 Toolbox from the list
of applicaons.
Step 2: Select RESTART FIS on the Main
selecon menu. (FIS = First Install
Sequence).
NOTE: Firmware is the soware
revision. Cycles are door
cycles in memory.
12

MC521 PRO Control Box
6 Document # 204066 REV F • www.stanleyaccess.com • 1.800.7.ACCESS
Copyright 2016, Stanley Access Technologies, LLC.
All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
12.28.2016
Step 3: Select Duraglide.Step 4: Select applicable Switch Type, Motor
Setup, and Motor Handing.
Step 5: If addional conguraon is needed,
press CONFIGURE DOOR.
Step 6: Congure addional sengs and press
UPDATE aer each seng has been
changed. Once completed, press
BACK to go back to the Main
selecon menu.
Step 7: Press BEGIN AUTOCONFIGURE.Step 8: Press NEXT.
34
5
6
78

MC521 PRO Control Box
12.28.2016
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204066 REV F 7
Copyright 2016, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
10
11
Step 9: Put door fucon switch to Hold Open
then immediately back to Closed. The
same funcon can be done remotely
from the Handheld by pressing Operate.
Step 10: For all doors except cart doors press
MOTOR 1 to operate and have door(s)
move. For cart doors, press MOTOR 2
when conguring the second door.
Step 11: If the door is not operang correctly
select TROUBLESHOOTING to enter the
Troubleshoong menu.
Step 12: View the I/O grid to verify the sensors
and inputs. Dark indicates input/
output contact is closed. Light
indicates input/output contact is
open. Gray never changes.
Step 13: Press MORE to access more funcons. Step 14: Output Control On displayed. See
Aachment 6 for more informaon.
13
14
**After performing Step 9 or 10, the door opens fully, delays and then closes fully. The MC521 Pro displays 00 when FIS is completed.**

MC521 PRO Control Box
8 Document # 204066 REV F • www.stanleyaccess.com • 1.800.7.ACCESS
Copyright 2016, Stanley Access Technologies, LLC.
All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
12.28.2016
15
Step 17: Sensor Monitoring On displayed
when congured for monitored
sensors.
Step 15: Press Summary lto view all
current sengs.
Step 16: Review the informaon on the
Summary lisng.
17
Autres manuels pour MC521 Pro
3
Table des matières
Autres manuels Stanley Contrôleurs

Stanley
Stanley EX5500 Manuel utilisateur

Stanley
Stanley Theta Controller Manuel utilisateur

Stanley
Stanley PAC 520 Manuel utilisateur

Stanley
Stanley JUMP iT J5C09D Manuel utilisateur

Stanley
Stanley DE-MC521 Manuel utilisateur

Stanley
Stanley 204143 Manuel utilisateur

Stanley
Stanley QB Expert Manuel utilisateur

Stanley
Stanley JUMPiT J309E Manuel utilisateur

Stanley
Stanley MC521 Pro Manuel utilisateur

Stanley
Stanley Magic-Swing HDLE Manuel utilisateur