Important Information
Product Overview l54 lContents
CLEANING
The uid product lines in Freepour must be
sanitised daily using Six Simple Machines line
cleaning chemicals that carry the Freepour logo.
Milk lines in Freepour must be sanitised with Daily
Milk Line Cleaner. Juice lines must be sanitised
with Daily Juice Line Cleaner.
NOTE: Our Daily Milk Line Cleaner (BLUE) and
Daily Juice Line Cleaner (RED) are dierent
chemical formulations. Our Daily Milk Line
Cleaner will not sanitise juice lines. Our Daily Juice
Line Cleaner will not sanitise milk lines.
IMPORTANT: If the lines are not sanitised properly
using the correct Six Simple Machines Freepour
line cleaner, the Freepour system may become
unsafe and make people sick.
Use of the correct Six Simple Machines Daily Line
Cleaners in your Freepour system is a condition of
our HACCP certication.
Failure to use the correct Six Simple Machines
Daily Line Cleaner in your Freepour system will
void the warranty on the Freepour dispensing
system.
Scan the QR codes on page 7 to see approved
varieties of milk and fruit juices and the
corresponding cleaning chemical.
REFRIGERATION
The Freepour Chiller contains R134A refrigerant
under pressure.
No part of the unit should be exposed to a naked
ame.
Maintenance of the refrigeration unit must be
carried out by an accredited service provider or
qualied refrigeration mechanic.
Always disconnect the cabinet from the mains
power supply before any cleaning or maintenance.
It is important that you follow the maintenance
procedures described on page 22.
Failure to keep the lter and condenser coil clean
will void the warranty on the Freepour Chiller.
AIRFLOW
To ensure ecient and safe operation of the
system, adequate air circulation must be provided
for the Chiller. Do not cover the Chiller grilles or
block entry or exhaust airows by placing objects
up against the Chiller.
Refer to page 10 for ventilation requirements
for the Freepour Chiller. There are no specic
ventilation requirements for the Control Unit.
LIFTING
Take care when lifting Freepour. Parts of the system
exceed safe lifting limits and require more than
one person to lift. Do not lift the Chiller by the
doors. If the Control Unit is xed to the Chiller, do
not lift the Chiller by the Control Unit.
ENVIRONMENT
This unit is intended for indoor use only and
should not be installed outdoors or exposed to the
elements of nature.
This unit should not be installed in an area that
may be cleaned by a water jet and must not be
cleaned by a water jet.
This unit can be used up to an altitude of 2000
meters above sea level.
The unit is designed to operate in ambient
temperatures between 16°C to 38°C.
If the unit is to be installed where there is risk that
water can freeze inside the hose that connects
the jug rinser to the mains water outlet, suitable
insulation should be added to the hose to
minimise this risk. If water in this hose does freeze,
it should be thawed before the hose is exed or
moved and the hose should be discarded and
replaced with a new one.
ALLERGEN ADVICE
On multi tap machines there is the risk that cross
contamination may occur between products being
dispensed. You should consider this as part of your
food allergen management program and ensure
your sta can eectively communicate this risk to
your customers.
4. FREEPOUR CHILLER 20
Freepour Chiller 20
Carel Easy electronic controller 20
Stand-by mode 20
Temperature setpoint 20
5. MAINTENANCE 22
Cleaning 22
Flush and sanitise milk lines 22
Deep clean 22
Condenser lter 22
Condenser coil 22
6. TROUBLESHOOTING 24
SAFETY FIRST!
Carefully read all instructions and ensure Freepour
is properly assembled before connecting to a power
outlet and operating.
This appliance can be used by persons (including
children aged 8 years and above) with reduced
physical, sensory or mental capabilities, or who
lack of experience or knowledge, if they have been
given supervision or instruction concerning the
safe use of the appliance by a person responsible
for their safety and they understand the hazards
involved.
Children should be supervised to ensure they do
not play with the appliance.
This appliance is only to be installed in locations
where it can be overseen by trained personnel.
Cleaning and maintenance shall not be preformed
by children without supervision.
Do not use this appliance for other than its
intended use.
Do not probe any opening.
The pumps must only be operated when
connected to the dispensing unit.
To protect against electric shock, do not immerse
cord, plug or appliance in water or any other liquid.
The power cables and power outlet must be in a
safe visible position for connection.
It is recommended to regularly inspect the
appliance. Do not use the appliance if power
supply cord, power plug, or appliance becomes
damaged in anyway.
The installation of a residual current device (safety
switch) is recommended to provide additional
safety protection when using electrical appliances.
It is advisable that a safety switch with a rated
residual operating current not exceeding 30mA
be installed in the electrical circuit supplying the
appliance. See your electrician for professional
advice. All electrical work must be performed by
authorised personnel.