1. General
IMPORTANT INSTRUCTIONS!
All safety and operating instructions should be read before the equipment is installed
or operated.
IMPORTANT SAFETY INFORMATIONS
The following general safety precautions have to be observed during all phases of
operation, service, and repair of this equipment. Failure to comply with these
precautions or with specific warning in this manual violates safety standards of
design, manufacture, and intended use of this equipment.
Do not operate in an explosive atmosp ere
Do not operate this equipment in the presence of flammable gases or fumes.
Operation of any electrical instrument in such an environment constitutes a definite
safety hazard.
Water, moisture, eat and umidity
Do not operate this equipment near water or in areas with wet floors, also not in high
humidity atmosphere where condensation forms on the equipment. It should never
be placed near or over heat register or other source of heated air and it should not
be installed or operated without proper ventilation.
Power connections
This equipment must be earthed
Wait for at least 10 minutes after the unpacking for adapting of the equipment.
Please double check the signals of the power cable. Cable must be 5 way ( L+N+E)
with the CEE form input socket 2A – 5 pin or hardwired to the installation rack.
Output connection
The output terminals are inside of the dimmer. Live, neutral and earth connections
must be made to all load equipment. Please look at PCB for more info about
connection of outputs/power input.
DMX Input connection
Male and female DMX standard pin and 5pin XLR connectors are based on the back
panel of DDP610. DMX input is opticaly isolated. Analog input (standard 0-10V) are
made thru D-SUB 9 pin connector.