10
Programming
Control Panel—Standard
The DISPLAY button is used to toggle between the various
modes. These modes are Off, Test, Setup, Run. Once the
desired mode is displayed press the SET button.
Off Mode—Turns the cellular alert off—Cancels Run Mode.
Test Mode—Used to test the alert function. When the Test
Mode is chosen, the LCD display will show diagnosis and status
information.
Setup Mode— Used to set the type of sensor and limits for the
alert and the type of alert desired. Using the up and down
arrows, toggle between the ‘Sensor’, ‘Limit’ and ‘Alert’. Pressing
the SET button will select the option shown on the LCD
Sensor— In the sensor setup the choices are:
Temperature in Fahrenheit, Temperature in Celsius,
Humidity, Wetness, and Voltage. Using the up and down
arrows toggle between the choices. Once the desired
sensor is displayed, press the SET button. The display
will toggle to Limit mode. Press SET again to enter Limit
setup mode.
Limit— The limit choices are Above or Below. To set the
temperature above, press the SET button and then using
the up and down arrow buttons set the correct
temperature. Once the temperature is reached, press the
SET button. The display will toggle to Alert. Press SET
again to select.