SpaGuts SG100-15UP Manuel utilisateur

UNIVERSAL TEE STYLE
Hydromassage Bath Heater
INSTALLATION INSTRUCTIONS
CARTON CONTENTS:
A - One (1) Whirlpool Bath Heater
B - Two (2) 1.5” X 0.75” tailpieces
C - Two (2) 1.5” X 1” tailpieces
D - Two (2) 1.5” X 1.5” tailpieces
E - Two (2) ridged heater gaskets
F - One (1) union gasket
G - One (1) #8AWG bonding wire
This Manual Covers:
Fig. 1
A
B
C
D
E
G
F
7” Models
SG100-15UP - 120V, 1500W SG202-20UP - 240V, 2000W
Designed to maintain bath water temperature and is not meant to heat water from cool or cold.

INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO
PERSON
WARNING - When using this unit, basic precautions should always be followed, including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS
2. The heater must be connected only to a supply circuit that is protected by a ground-fault-circuit-
interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine
basis. To test the GFCI, push the test button. The GFCI should interupt power. Push the reset button.
The Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the
GFCI interrupts power to the heater without the test button being pushed, a ground current is flowing,
indicating the possibility of an electrical shock. Do not use this hydromassage bathtub. Disconnect this
hydromassage bathtub and have the problem corrected by a qualified service representative before
using.
3. SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
Prolonged immersion in hot water may induce hyperthermia. Causes, symptoms, and effects of
hyperthermia:
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above
the normal body temperature of 98.6F. The symptoms of hyperthermia include an increase in the internal
temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia
include:
A) Failure to perceive heat,
B) Failure to recognize the need to exit the bathtub,
C) Unawareness of impending hazard,
D) Fetal damage in pregnant women,
E) Physical inability to exit the bathtub, and
F) Unconsciousness resulting in the danger of drowning.
WARNING - The use of alcohol, drugs, or medication can greatly increase the risk of fatal
hyperthermia.
1

CONTENTS
GLOSSARY
SAFETY INSTRUCTIONS
CONTENTS & GLOSSARY
MODEL IDENTIFICATION
INSTALLATION INSTRUCTIONS (Heater Ready fitting Installed)
Installation
INSTALLATION INSTRUCTIONS (No Heater Ready fitting)
Installation
ELECTRICAL REQUIREMENTS
BONDING YOUR HEATER
TEST YOUR INSTALLATION
TROUBLESHOOTING
INSTALLATION NOTES
WARRANTY INFORMATION
TEMPLATE ILLUSTRATION
TEMPLATE CUTOUT
1
2
3
5
6
8
9
10
11
12
13
14
15
Reading all instructions prior to beginning the installation of your Whirlpool heater will
ensure that you have:
A) Purchased the correct heater
B) Identified the installation location
C) The necessary electrical connection has been provided
7”
De-burr
Inline Heater
Heater Ready Fitting
Pump Union
PVC
Tailpiece
Tee Heater
“UP” Series
“UV” Series
Refers to Whirlpool Bath Heaters where stainless steel heater housing measures 7 inches from flat sealing
surface to flat sealing surface.
Refers to removing excess plastic that may have built up during the cutting process.
A heater that can be installed directly inline in the existing plumbing system of a hydromassage bathtub.
Molded plastic heater blank assembly, provided for ease of aftermarket heater installation.
Refers to the plastic pieces used to join the bathtubs plumbing system to the hydromassage jet pump.
Refers to the plastic plumbing system of your hydromassage bathtub. This will be referred to during the
cutting and glueing procedures.
Refers to the threaded plastic pieces included with your heater that are glued to the hydromassage
bathtubs plumbing and allow the heater to be attached.
A heater that is just that, shaped like a “T”. These heaters connect directly to the pump of a
hydromassage bathtub.
Pressure - Refers to the “discharge” side of the pump. The water discharged from the pump supplies all of
the pressure fittings such as the hydromassage jets that eject water into the bathtub. Throughout these
instructions discharge will be referred to as “pressure”.
Vacuum - Refers to the “suction” side of the pump. The water that is pulled through the bathtubs suction
fitting is routed to the pump via the “vacuum” plumbing. Throughout these instructions suction will be
referred to as “vacuum”.
2

MODEL IDENTIFICATION
If your hydromassage bathtub has been equipped at the factory with a Heater Ready fitting, installing
your Whirlpool heater is a snap. (See figures 2 & 3 below for common heater location.) Note: these
instructions do not cover the Inline Style hydromassage bathtub heater.
Fig. 2
INLINE HEATER
TEE HEATER
VACUUM MODELS
PRESSURE MODELS HEATER READY
HEATER READY
HEATER READY
PROCEED
TO PAGE 5
Fig. 3
!! STOP !!
These instructions do
not cover the Inline
Style heater - Arrange to
receive the proper
heater and refer to the
enclosed installation
instructions.
-UP SERIES
PRESSURE
HEATER READY FITTING INSTALLED
3

CLEARANCE:
Your Whirlpool heater has been specifically designed
to be compact and easy to install. In most cases
there will be no interference installing your
hydromassage bathtub with the addition of a Pure
Heat heater. Prior to installing your heater, consult
manufacturers instructions regarding bathtub
installation clearance requirements.
If your hydromassage bathtub did not come equipped with a Heater Ready fitting you will need to install
your Whirlpool heater onto the bathtubs jet pump, cutting away excess plumbing and installing the
tailpieces included. Be sure the location will be accessible if a need for service should arise. (See figure 4
below for common heater location.)
HEATER MOUNTS HERE
TEE-STYLE PRESSURE HEATER
Fig. 4
PROCEED
TO PAGE 6
MODEL IDENTIFICATION
-UP SERIES
PRESSURE
NO HEATER READY FITTING
Fig. 5
4

TEE STYLE INSTALLATION
1 - Power to the hydromassage bathtub must be turned OFF and all water must be drained from
the bathtub before proceeding.
2 - Loosen nuts (3) and remove Heater Ready fitting and existing gaskets.
3 - Remove two (2) heater gaskets included with your Whirlpool heater and install them onto the
plumbing tailpieces, making sure the gasket ridge is seated in the tailpiece groove (see Fig. 7).
Remove one (1) union gasket and install at pump discharge.
TAILPIECE TAILPIECE
GASKET GASKET
PLUMBING PLUMBING
4 - You are now ready to install the heater in the open space where the Heater Ready fitting was located
(ensure that the gaskets remain in place). Slide heater nuts inward toward the center of the heater to
expose the mating surfaces of the heater housing. Slide the heater carefully into place between the
tailpieces and gaskets, pump and union gasket and hand-tighten heater nuts. If you use a wrench be
careful not to over-tighten, the nuts can crack.
Fig. 7
Fig. 8
Fig.6
CONTINUE ON TO PAGE 9
“BONDING YOUR HEATER”
-UP SERIES
PRESSURE Heater Ready Fitting Installed
HEATER READY
IF THERE IS INSUFFICIENT
SPACE BETWEEN THE HEATER
AND JET PUMP IT MAY BE
NECESSARY TO INSTALL AN
EXTENDED TEE HEATER.
5

1 - Power to the hydromassage bathtub must be turned OFF and all water must be drained
from the bathtub before proceeding.
2 - Locate the hydromassage jet pump in the plumbing in the system.
3 - For convenience, a template has been provided on the back page of this instruction booklet. Simply
detach, position against plumbing and mark according to plumbing size.
4 - Using a hacksaw, PVC cutter or a cable saw, cut the pipe at the marks made. If using a cable saw,
carefully line the saw blade up with the marks that were made in the previous step and begin cutting
using an alternating pulling/releasing motion (see Fig. 10). Once both cuts have been successfully
made, loosen and discard PVC “T” fitting and detached portion of plumbing.
Fig. 10
-UP SERIES
PRESSURE
No Heater Ready Fitting -UP SERIES
PRESSURE
5 - De-burr the plumbing, clean outer surface of plumbing and prepare the surfaces for gluing.
6 - Your Whirlpool heater includes three (3) sets of tailpieces to adapt the heater to virtually any
hydromassage bathtubs plumbing system. Dry fit the tail pieces to determine which tailpieces adapt
properly to your plumbing and discard the tailpieces that do not fit.
Note: Let the saw blade do the
work, do not put excess pressure
on the plumbing. Have someone
else stabilize the plumbing while
you cut if needed.
Fig. 9
Template located on
back page. Cut and
detach
TEE STYLE INSTALLATION
6

7 - You are now ready to install the tailpieces onto the bathtub plumbing. Apply PVC glue to one end
of the plumbing. Spread glue evenly over a 1-1/4” area from the end of the cut. Quickly apply
glue to the inside socket of the tailpiece. Before the glue dries, slide the tailpiece onto the
plumbing with a slight twisting motion assuring it has reached the stop built into the tailpiece and
hold for 15-seconds to allow the glue to setup. Wipe away any excess glue and repeat the gluing
process on the second tailpiece. Once the glue has set, you should have approximately 7”
opening for part numbers SG100-15UP & SG202-20UP (see Fig. 11) in order to install your
Whirlpool heater.
Fig. 12
Fig. 11
8 - Remove two (2) heater gaskets included with your Whirlpool heater and install them onto the
plumbing tailpieces, making sure the gasket ridge is seated in the tailpiece groove (see Fig. 13).
Remove one (1) union gasket and install at pump discharge.
PRESSURE INSTALLATION
(continued)
9 - You are now ready to install the heater in the open space where the Heater Ready fitting was located
(ensure that the gaskets remain in place). Slide heater nuts inward toward the center of the heater to
expose the mating surfaces of the heater housing. Slide the heater carefully into place between the
tailpieces and gaskets, pump and union gasket and hand-tighten heater nuts. If you use a wrench be
careful not to over-tighten, the nuts can crack.
CONTINUE ON TO PAGE 9
“BONDING YOUR HEATER”
TAILPIECE TAILPIECE
GASKET GASKET
PLUMBING PLUMBING
Fig. 13
Fig. 14
IF THERE IS INSUFFICIENT
SPACE BETWEEN THE HEATER
AND JET PUMP IT MAY BE
NECESSARY TO INSTALL AN
EXTENDED TEE HEATER.
-UP SERIES
PRESSURE No Heater Ready Fitting
7”
7

ELECTRICAL REQUIREMENTS
DEDICATED CIRCUIT INSTALLATION
A qualified and licensed electrician in accordance with the National Electric Code (NEC) Article 680,
Canadian Electric Code, and with any local codes must accomplish the electrical installation.
All connections must be made according to the electrical installation label on the outside of the control
box. Follow the instructions from the label if they are different than the instructions in this manual. If your
electrician is not absolutely sure how to connect your system correctly, call your local dealer. Any mistake
may be costly and void your equipment warranty.
The GFCI (Ground Fault Circuit Interrupter) is a mandatory electrical safety device required for all
hydromassage bathtubs as specified in the National Electrical Code Article 680-70.
Your bath equipment may require a DEDICATED CIRCUIT. This means no other appliances or lights
can be on this circuit. Refer to equipment data label for power supply requirements of your bath
heater.
Use copper conductors ONLY. The ground must be sized following the National Electric Code, Table
250-122.
For Power conductor size, refer to the National Electric Code Table 310-16.
SG202-20UP
SG100-15UP
8
12
10
15
YES
YES
YES
YES
MODELS
MAX
AMPS
CIRCUIT
BREAKER
GFCI
REQUIRED
BONDING
REQUIRED
NOTE: Read both the “Dedicated Circuit” and “Single Circuit” sections to determine the
electrical requirements of your heater before proceeding.
These models will most likely require a dedicated circuit due to their high power demand
and voltage requirements.
RESET
TEST
RESET
TEST
ELECTRICAL
PANEL
TWO (2) SINGLE CIRCUITS
15A / 115V OR 10A / 240V**
BRANCH CIRCUIT
15A / 115V OR 10A / 240V**
BRANCH CIRCUIT
**240V Heater cords do not have a Nema plug and require hard wiring of the unit.
8

1 - Prior to testing your installation for leaks, you must properly bond the Whirlpool Bath Heater to the
bonding system of your hydromassage bathtub. All Whirlpool Bath Heaters come equipped with a
bonding lug and 8AWG bonding wire specifically for this purpose. Refer to bathtub manufacturers
instructions to locate the bonding system. All electrical wiring and bonding must be done as specified
in Article 680, National Electric Code and your local Building Code.
8AWG Bonding Wire
(Included with your heater - *May Be on Bottom of Tube*)
To Bathtub
Bonding System
BONDING YOUR HEATER
Bonding Lug
Fig. 23
7” Tee Shown
SINGLE CIRCUIT INSTALLATION**
In certain cases you may be able to plug the heater and the pump into the same single circuit outlet.
This generally requires that one or both of the components have a very low amperage rating. See the
chart below to determine if your components are sized to allow this type of installation.
If your heater
amps are . . .
AND THEN
Your pump amps
are less than. . .
10.6A
You can use a single
circuit this size
20A
5.4A (650W)
ELECTRICAL
PANEL
ONE (1) SHARED CIRCUIT
RESET
TEST
15A / 115V OR 20A / 115V
BRANCH CIRCUIT
**Single circuit installation does not apply to 240V heaters.
R
C
US
9
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels SpaGuts Chauffage
Manuels Chauffage populaires d'autres marques

oventrop
oventrop Regucor Series Manuel utilisateur

Blaze King
Blaze King CLARITY CL2118.IPI.1 Manuel utilisateur

ELMEKO
ELMEKO ML 150 Manuel utilisateur

BN Thermic
BN Thermic 830T Manuel utilisateur

KING
KING K Series Mode d’emploi

Empire Comfort Systems
Empire Comfort Systems RH-50-5 Guide de démarrage rapide

Empire Heating Systems
Empire Heating Systems WCC65 Manuel utilisateur

Wetekom
Wetekom 92 86 43 Manuel utilisateur

Desa
Desa SPC170-F Manuel utilisateur

Watlow
Watlow Watrod Electric Tubular Heaters Manuel utilisateur

Haverland
Haverland ECO-DRY GPS Series Manuel de la liste des pièces

Stelpro
Stelpro ASILVC2060 Series Manuel utilisateur