• This unit is used near equipment that generates electromagnetic interference.
• The frequency of the voltage is not a perfect sine wave between 50 and 500Hz.
• The detector is outside of operation conditions (listed in Specifications
section).
• Operation may be affected by differences in socket design and insulation
thickness and type.
WARNING: Never assume neutral or ground wires are de-energized. Neutrals in
multi-wire branch circuits may be energized when disconnected and must be
retested before handling.
There may be times when your detector does not operate properly. Here are
some common problems that you may have and some easy solutions to them.
1. Always read all the instructions in this manual before use.
2. Check to be sure the batteries are properly installed.
3. Check to be sure the batteries are good.
4. If the battery is good and the detector still does not operate, check to be sure
that both ends of the fuse are properly installed.
5. If everything else seems to be correct then the batteries may not contact
properly. Open the detector, extract the batteries and find the little metal plate
in the bottom. Catch it with tweezers and pull out to bend it a little so that it will
truss the batteries firmly.
Specifications
Detection range: 90~1000V AC
Measurement category: Cat IV
Operating Temperature: 32 to 122F (0 to 50degree)
Storage Temperature: -4 to 140F (-20 to 60degree)
Humidity: < 85%RH
Battery: 2 * 1.5V AAA Batteries
Flash light: white
Detection Light: red