6. After expansion of screen, the following screen will appear. Screen parameters description is as below:
P1: Total Number of Alarm set bit(s) available in AlSt1 and AlSt2
P2: Operation Status (OpSt1)
P3: Regulation Probe Temperature. If bit#0: Regulation probe faulty is high in AlSt1,
it displays “Faulty”. If Regulation Probe Temperature is not congured, it displays
“NA”.
P4: Defrost Probe Temperature. If bit#1: Defrost probe faulty is high in AlSt1, it
displays “Faulty”. If Defrost Probe Temperature is not congured, it displays “NA”.
P5: Condenser Probe Temperature. If bit#2: Condenser probe faulty is high in
AlSt1 it displays “Faulty” . If Condenser Probe Temperature is not congured
it displays “NA”there. If bit#3: Condenser High Temperature is high in AlSt2 it
displays “High” with temperature value. If bit#4: Condenser Low Temperature is
high in AlSt2 it displays “Low”with temperature value.
P6: Ambient Probe Temperature. If bit#3: Ambient probe faulty is high in AlSt1
it displays “Faulty” there. If Ambient Probe Temperature is not congured it
displays “NA” .
P7: Door Status. If bit#5: Door Alarm is high in AlSt1 it displays “Alarm” also. If bit#6:
Door Malfunction is high in AlSt1 it displays “Malfunction”.
P8: Average Input voltage (IpVAv). If bit#0: High Voltage or bit#1: Low Voltage is
high in AlSt2 it displays “(High)”and “(Low)” respectively with value of voltage.
P9: Compressor Relay Status (bit#0 in RlSt)
P10: Condenser and Evaporator Fan Relay Status (bit#1 and 2 in RlSt)
P11: Heater Relay Status (bit#4 in RlSt)
P12: Light Relay Status (bit#3 in RlSt)