SOLE AIRSOL Manuel utilisateur

GB
EL
GB
AIR COLLECTORS ’’AIRSOL’’
INSTALLATION AND USER MANUAL
MODELS: AIRSOL 10, AIRSOL 20 &
AIRSOL 35

Page2
INDEX
PAGE
1. Presentation ……………………………………………………………………..
3
2. Introduction ...............................................................................................
5
3. Parts Included ……………………………………………………………………
5
3.1. Solar Collectors …………………………………………………………….
5
4. Installation …………………………………………………….........................
6
4.1. Flat roof vertical installation................................................................
7
4.2 Flat roof horizontal installation ………………………...........................
8
4.3 Wall mounting installation………….....................................................
9
5. Recirculation ……………………………………………................................
10
6. Air Filter ………………………………………………………………...............
11
7. Summer Season ……………………………………………..........................
11
8. Room Thermostat....................………………………………………………..
12
9. General instructions ................................................................................
13
10. Care and Maintenance Program ...........................................................
13

Page3
1. Presentation
The solar air collector AIRSOL heats air that flows inside the room area with the help of an
integrated fan.
The fan operates with solar photovoltaic panels that are also built into the unit. For big industrial
projects the AIRSOL 35, is also available without PV and fan.
The device can take fresh air from the ambient OR recirculated air from the heated room. It is also
possible for the user to adjust it to partially recirculated air with a supplement of fresh air.
In any case the air is filtered before is heated and flows into room space.
The AIRSOL can be installed on a South or Southeast or Southwest wall (for the northern
hemishpere) (see drawing 1, 1a &1b) or on a terrace (see drawings 2& 3) or on a tile roof (see
drawing 4).
For the AIRSOL 10 & 20 you will need a duct of Ø100 diameter of proportional length and similar
grille, for the AIRSOL 35 a duct of Ø200 diameter will be needed.
DRAWING 1
DRAWING 1b
DRAWING 1a

Page4
DRAWING 2 DRAWING 3
DRAWING 4

Page5
2. Introduction
The present document demonstrates detailed installation instructions for the solar collectors using
the support frames and accessories included in the supply.
Before proceeding with the installation of the collectors, read these instructions and make sure you
have understood. If you have questions about the materials or on the assembly process described
in this document, contact your supplier via telephone, fax or e-mail. Improper installation of the
collectors may cause an unsatisfactory operation of the solar system, compromising its durability
and even be dangerous for the people or the goods.
The instructions of this document do not exempt in any way the compliance with existing
regulations and provisions of technical and administrative application at the place where the facility
is located.
The installation of solar collectors without following the instructions in this document and / or
regulations will invalidate the warranty of the product.
The installer will check before starting the installation that he has all the necessary parts and all the
security measures have been taken in order to carry out the installation safely. The installer must
use protective gloves to avoid any risk of burns or cuts during handling of collectors or its support
frame.
3. Parts Included
The supply consists of:
One or more solar collectors
One or more support frames
One or more fitting and accessories.
3.1. Solar Collectors
3.1.1. Models
3.1.2. Packaging
The solar air collectors are supplied individually packaged in carton boxes. The collector model is
indicated on the outside of each box. Depending on the number of units ordered, collectors can be
supplied palletised in groups of up to 7 units.
TYPE
DIMENSIONS (mm)
SURFACE
m²
NOMINAL VALUE**
RECOMMENDED
FOR ROOM AREA
AIRSOL 10
1545x700x178
1,08
700Wp
10 to 40 m²
AIRSOL 20
2050x1040x195
2,13
1500Wp
20 to 60 m²
AIRSOL 35
2833x1285x140
3,65
2700Wp
35 to100 m²

Page6
4. Installation
The support frames sets are composed of elements that are shown in Figures 1 & 2.
Figure 1
Figure 2

Page7
4.1. Flat Roof Horizontal Installation
Take off the cover of the carton box and remove the polystyrene protections (see pictures no. 1 &
2).The support frame consists of two triangles frames, partly preassembled. Screw the profiles A
and C with the bolts and nuts provided and tighten.(see picture no. 4).
Fix part B of the triangle frame on the corresponding nuts on the collector (see picture 5) and
tighten with bolts M6.
Lift the collector and join the structure to the floor, placing the collector in operation position and fit it
using the raw plugs and anchored bolts supplied on the flat roof (see pictures 7 & 8).
A
B
C
B
A
C
B
B
C
A
B

Page8
4.2. Flat Roof Vertical Installation
The assembly of solar air collectors on a flat roof in vertical position is done in a manner similar to
that described above; with different size of the support triangles frame placed vertically in a parallel
manner on the back of the collector (see picture 9).
Lift the collector and join the structure to the floor, placing the collector in operation position and fit it
using the raw plugs and anchored bolts supplied on the flat roof (see pictures 11-12).

Page9
4.3. Wall Mounting Installation
Take off the cover the carton box and remove the polystyrene protections (see picture no.1).The
support frame consists of 4 stainless steel mounting brackets. Fix the 4 mounting brackets on the
corresponding nuts on the collector (see picture no.13) and tighten with bolts M6 (see picture no.
14 & 15)
Lift the collector and join the structure to the wall using the raw plugs and anchored bolts (see
picture no. 16).

Page10
5. Recirculation
In case of installation with recirculation (see drawing 1b), the sliding entrance door of ‘’COLD AIR
IN’’ must be ‘’INSIDE’’.
SLIDING DOOR ‘’INSIDE’’
For a 100% fresh air the sliding door must be ‘’OUT’’.
SLIDING DOOR ‘’OUT’’
For recirculation 50% and fresh air 50% the sliding door of ‘’COLD AIR IN’’ must be in the
‘’MIDDLE’’.
SLIDING DOOR MUST BE IN THE ‘’MIDDLE’’
Ce manuel convient aux modèles suivants
3
Table des matières
Manuels Chauffage populaires d'autres marques

oventrop
oventrop Regucor Series Manuel utilisateur

Blaze King
Blaze King CLARITY CL2118.IPI.1 Manuel utilisateur

ELMEKO
ELMEKO ML 150 Manuel utilisateur

BN Thermic
BN Thermic 830T Manuel utilisateur

KING
KING K Series Mode d’emploi

Empire Comfort Systems
Empire Comfort Systems RH-50-5 Guide de démarrage rapide

Empire Heating Systems
Empire Heating Systems WCC65 Manuel utilisateur

Wetekom
Wetekom 92 86 43 Manuel utilisateur

Desa
Desa SPC170-F Manuel utilisateur

Watlow
Watlow Watrod Electric Tubular Heaters Manuel utilisateur

Haverland
Haverland ECO-DRY GPS Series Manuel de la liste des pièces

Stelpro
Stelpro ASILVC2060 Series Manuel utilisateur