SMA RoofCommKit-P2-US Manuel utilisateur

RoofCommKit-P2-US-IA-xx-10 | 112604-00.01 | Version 1.0
SMA ROOFTOP COMMUNICATION KIT
(RoofCommKit-P2-US)

RoofCommKit-P2-US-IA-xx-102
ENGLISH Installation manual ...................................................................3
ESPAÑOL Instrucciones de instalación ...................................................24
FRANÇAIS Instructions d’installation........................................................46

Legal Provisions
SMA Solar Technology America LLC
Installation manual RoofCommKit-P2-US-IA-xx-10 3
Legal Provisions
No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any
form or by any means, be it electronic, mechanical, photographic, magnetic or otherwise, without
the prior written permission of SMA Solar Technology America LLC.
Neither SMA Solar Technology AmericaLLC nor SMA Solar Technology Canada Inc. makes
representations, express or implied, with respect to this documentation or any of the equipment
and/or software it may describe, including (with no limitation) any implied warranties of utility,
merchantability, or fitness for any particular purpose. All such representations or warranties are
expressly disclaimed. Neither SMA Solar Technology AmericaLLC nor its distributors or dealers nor
SMA Solar Technology Canada Inc. nor its distributors or dealers shall be liable for any indirect,
incidental, or consequential damages under any circumstances.
The exclusion of implied warranties may not apply in all cases under some statutes, and thus the
above exclusion may not apply.
Specifications are subject to change without notice. Every attempt has been made to make this
document complete, accurate and up-to-date. Readers are cautioned, however, that product
improvements and field usage experience may cause SMA Solar Technology America LLC and/or
SMA Solar Technology Canada Inc. to make changes to these specifications without advance
notice, or per contract provisions in those cases where a supply agreement requires advance
notice. SMA shall not be responsible for any damages, including indirect, incidental or
consequential damages, caused by reliance on the material presented, including, but not limited to,
omissions, typographical errors, arithmetical errors or listing errors in the content material.
Trademarks
All trademarks are recognized, even if not explicitly identified as such. Missing designations do not
mean that a product or brand is not a registered trademark.
SMASolar TechnologyAmerica LLC
6020 West Oaks Blvd.
Suite 300 Rocklin, CA 95765 U.S.A.
SMA Solar Technology Canada Inc.
2425 Matheson Blvd. E
7th Floor
Mississauga, ON L4W 5K4
Canada
Status: 11/17/2017
Copyright©2017SMA Solar Technology America LLC. All rights reserved.
ENGLISH

Important Safety Instructions SMA Solar Technology America LLC
Installation manualRoofCommKit-P2-US-IA-xx-104
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains important instructions for the following products:
• RoofCommKit-P2-US (SMA Rooftop Communication Kit)
• SB3.0-1SP-US-40 (Sunny Boy 3.0-US)
• SB3.8-1SP-US-40 (Sunny Boy 3.8-US)
• SB5.0-1SP-US-40 (Sunny Boy 5.0-US)
• SB6.0-1SP-US-40 (Sunny Boy 6.0-US)
• SB7.0-1SP-US-40 (Sunny Boy 7.0-US)
• SB7.7-1SP-US-40 (Sunny Boy 7.7-US)
This manual must be followed when using this product.
The product is designed and tested in accordance with international safety requirements, but as
with all electrical and electronic equipment, certain precautions must be observed when installing
and/or operating the product. To reduce the risk of personal injury and to ensure the safe
installation and operation of the product, you must carefully read and follow all instructions,
cautions and warnings in this manual.
Warnings in this Document
A warning describes a hazard to equipment or personnel. It calls attention to a procedure or
practice, which, if not correctly performed or adhered to, could result in damage to or destruction
of part or all of the equipment and/or other equipment connected to the equipment or personal
injury.
DANGER
Safety information that, if not avoided, will result in death or serious injury.
WARNING
Safety information that, if not avoided, could result in death or serious injury.
CAUTION
Safety information that, if not avoided, can result in minor or moderate injury.
NOTICE
Safety information that, if not avoided, can result in property damage.
Warnings on this Product
The following symbols are used as product markings with the following meanings.
ENGLISH

General Warnings
SMA Solar Technology America LLC
Installation manual RoofCommKit-P2-US-IA-xx-10 5
General Warnings
WARNING
All electrical installations must be carried out in accordance with the local electrical standards
and the National Electrical Code® ANSI/NFPA70 or the Canadian Electrical Code®
CSAC22.1. This document does not replace and is not intended to replace any local, state,
provincial, federal or national laws, regulations or codes applicable to the installation and use of
the product, including without limitation applicable electrical safety codes. All installations must
conform with the laws, regulations, codes and standards applicable in the jurisdiction of
installation. SMA assumes no responsibility for the compliance or non-compliance with such laws
or codes in connection with the installation of the product.
The product contains no user-serviceable parts.
For all repair and maintenance, always return the unit to an authorized SMA Service Center.
Before installing or using the product, read all of the instructions, cautions, and warnings in this
manual.
Wiring of the product must be made by qualified personnel only.
ENGLISH

Table of Contents SMA Solar Technology America LLC
Installation manualRoofCommKit-P2-US-IA-xx-106
Table of Contents
1 Information on this Document................................................. 7
1.1 Validity........................................................................................................................ 7
1.2 Target Group.............................................................................................................. 7
1.3 Symbols ...................................................................................................................... 7
1.4 Typographies.............................................................................................................. 7
2 Safety ........................................................................................ 8
2.1 Intended Use .............................................................................................................. 8
2.2 Safety Information...................................................................................................... 9
3 Scope of Delivery..................................................................... 12
4 Mounting................................................................................... 13
4.1 Mounting position ...................................................................................................... 13
4.2 Installing the Module ................................................................................................. 13
4.3 Mounting the Gateway ............................................................................................. 15
5 Connection................................................................................ 17
5.1 Connecting the Gateway .......................................................................................... 17
6 Commissioning the Rooftop Communication Kit ................... 20
7 Disposing of the Product.......................................................... 21
8 Contact ...................................................................................... 22
9 Compliance Information.......................................................... 23
ENGLISH

1 Information on this Document
SMA Solar Technology America LLC
Installation manual RoofCommKit-P2-US-IA-xx-10 7
1 Information on this Document
1.1 Validity
This document describes the assembly and installation of approved accessories in SMA inverters.
This document supplements the documents that are enclosed with each inverter and does not
replace any locally applicable codes or standards. Read and observe all documents supplied with
the inverter.
This document applies to the SMARooftopCommunicationKit (RoofCommKit-P2-US).
1.2 Target Group
The tasks described in this document must only be performed by qualified persons. Qualified
persons must have the following skills:
• Knowledge of how an inverter works and is operated
• Training in how to deal with the dangers and risks associated with installing and using
electrical devices and installations
• Training in the installation and commissioning of electrical devices and installations
• Knowledge of the applicable standards and directives
• Knowledge of and compliance with this document and all safety information
1.3 Symbols
Symbol Explanation
Information that is important for a specific topic or goal, but is not
safety-relevant
Indicates a requirement for meeting a specific goal
Desired result
A problem that might occur
1.4 Typographies
Typography Use Example
bold • Terminals
• Slots
• Parameters
• Elements on the user interface
• Elements to be selected
• Elements to be entered
• The value can be found in
the field Energy.
• Select Settings.
• Enter 10 in the field
Minutes.
>• Connects several elements to be
selected
• Select Settings > Date.
[Button]• Button to be selected or pressed • Select [Next].
ENGLISH

2 Safety SMA Solar Technology America LLC
Installation manualRoofCommKit-P2-US-IA-xx-108
2 Safety
2.1 Intended Use
The SMARooftopCommunicationKit is a communication set for TS4 module technology
components. The SMARooftopCommunicationKit enables direct connection of the inverter to the
Gateway.
SUNNY PORTAL/
SUNNY PLACES
INTERNET
TS4 GATEWAY
(GTWY)
...
...
...
UTILITY GRID
PV GENERATOR
ROUTER
PV INVERTER
with ROOFTOP
COMMUNICATION KIT
AC
DC Ethernet RS485 Radio
Figure 1 : System overview
The SMARooftopCommunicationKit must only be installed in the following SMAinverters with a
firmware version higher than 2.03.01.R:
• SB3.0-1SP-US-40 (Sunny Boy 3.0-US)
• SB3.8-1SP-US-40 (Sunny Boy 3.8-US)
• SB5.0-1SP-US-40 (Sunny Boy 5.0-US)
• SB6.0-1SP-US-40 (Sunny Boy 6.0-US)
• SB7.0-1SP-US-40 (Sunny Boy 7.0-US)
• SB7.7-1SP-US-40 (Sunny Boy 7.7-US)
ENGLISH

2 Safety
SMA Solar Technology America LLC
Installation manual RoofCommKit-P2-US-IA-xx-10 9
The inverter still complies with the standard after the product has been installed.
The product is approved for the US and Canadian market.
All components must remain within their permitted operating ranges and their installation
requirements at all times.
Use this product only in accordance with the information provided in the enclosed documentation
and with the locally applicable standards and directives. Any other application may cause
personal injury or property damage.
Alterations to the product, e.g. changes or modifications, are only permitted with the express written
permission of SMA. Unauthorized alterations will void guarantee and warranty claims and in most
cases terminate the operating license. SMA shall not be held liable for any damage caused by
such changes.
Any use of the product other than that described in the Intended Use section does not qualify as the
intended use.
The enclosed documentation is an integral part of this product. Keep the documentation in a
convenient place for future reference and observe all instructions contained therein.
2.2 Safety Information
This section contains safety information that must be observed at all times when working on or with
the product.
To prevent personal injury and property damage and to ensure long-term operation of the product,
read this section carefully and observe all safety information at all times.
DANGER
Danger to life due to high voltages of the PV array
When exposed to light, the PV array generates dangerous DC voltage, which is present in the
DC conductors and the live components of the inverter. Touching the DC conductors or the live
components can lead to lethal electric shocks.
• Prior to performing any work on the inverter, always disconnect the inverter from voltage
sources on the AC and DC sides as described in the inverter manual. When doing so, note
that even if the DC load-break is switched off, there will be dangerous direct voltage present
in the DC conductors of the inverter.
CAUTION
Increased electromagnetic radiation through the antenna
During operation, the antenna produces an electromagnetic field and can interfere with other
devices (e.g., pacemakers) due to electromagnetic interference.
• Persons must not remain closer than 20 cm (8 in) to the antenna for long periods of time.
ENGLISH

2 Safety SMA Solar Technology America LLC
Installation manualRoofCommKit-P2-US-IA-xx-1010
NOTICE
Damage to seals on the enclosure lids in subfreezing conditions
If you open the enclosure lids when temperatures are below freezing, the enclosure seals can be
damaged. Moisture can penetrate the product then.
• Only open the enclosure lid if the ambient temperature is not below 0°C (32°F).
• If a layer of ice has formed on the seal of the lid when temperatures are below freezing,
remove it prior to opening the enclosure lids (e.g. by melting the ice with warm air).
Observe the applicable safety regulations.
NOTICE
Damage to the inverter or product due to electrostatic discharge
Touching electronic components can cause damage to or destroy the inverter or the product
through electrostatic discharge.
• Ground yourself before touching any component.
NOTICE
Damage to the inverter due to moisture ingress during electrical installation
• Never open the inverter when it is raining or snowing, or the humidity is over 95%.
• For attaching the conduits to the enclosure, only use UL-listed rain-tight conduit fittings for
wet locations.
• Seal all unused openings tightly.
NOTICE
Damage to communication assembly in the inverter due to an interruption in
the voltage supply during the firmware update
The firmware update to a version higher than 2.03.01.R may take approx. 30minutes. The
inverter must be continually supplied with voltage for the entire course of the firmware update.
• Ensure that the inverter is supplied with voltage during the firmware update to a version
higher than 2.03.01.R.
ENGLISH
Ce manuel convient aux modèles suivants
6
Table des matières
Langues :
Autres manuels SMA Système de conférence
Manuels Système de conférence populaires d'autres marques

Kramer
Kramer VIA GO Manuel utilisateur

AVT
AVT MAGIC AC1 Go Manuel utilisateur

ProSoft Technology
ProSoft Technology AN-X4-AB-DHRIO Manuel utilisateur

Sony
Sony PCS-I150 Manuel utilisateur

Middle Atlantic Products
Middle Atlantic Products VTC Series Manuel utilisateur

Prentke Romich Company
Prentke Romich Company Vanguard Plus Mode d’emploi